RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCIESCOPUSKCI등재

        Effect of GLUMA desensitizer on the retention of full metal crowns cemented with Rely X U200 self-adhesive cement

        Lawaf, Shirin,Jalalian, Ezatallah,Roshan, Roshanak,Azizi, Arash The Korean Academy of Prosthodonitics 2016 The Journal of Advanced Prosthodontics Vol.8 No.5

        PURPOSE. Considering the importance of retention in the success and long-term clinical service of fixed partial dentures (FPDs) as well as the existing controversy regarding the effect of GLUMA desensitizer on the retention of full metal crowns cemented with RelyX U200 self-adhesive cement, this study aimed to assess the effect of GLUMA desensitizer on the retention of full metal crowns cemented using RelyX U200. MATERIALS AND METHODS. In this experimental study, 20 sound human premolars were prepared; a 0.5 mm chamfer finish line was prepared above the cementoenamel junction. The teeth were randomly assigned to two groups: a desensitizer group (n = 10, treated with GLUMA desensitizer) and a control (n = 10, no surface treatment). Full metal crowns were fabricated of base metal alloy and had a ring. All crowns were cemented with RelyX U200 and subjected to retention test by using a universal testing machine. The data were analyzed using SPSS version 20 and independent t-test. RESULTS. The mean tensile bond strength was significantly higher in the GLUMA desensitizer group ($230.63{\pm}63.8N$) compared to the control group ($164.45{\pm}39.3N$) ($P{\leq}.012$). CONCLUSION. GLUMA desensitizer increases the tensile bond strength of RelyX U200 self-adhesive cement to dentin.

      • SCIESCOPUSKCI등재

        Comparison of the bond strength of ceramics to Co-Cr alloys made by casting and selective laser melting

        Lawaf, Shirin,Nasermostofi, Shahbaz,Afradeh, Mahtasadat,Azizi, Arash The Korean Academy of Prosthodonitics 2017 The Journal of Advanced Prosthodontics Vol.9 No.1

        PURPOSE. Considering the importance of metal-ceramic bond, the present study aimed to compare the bond strength of ceramics to cobalt-chrome (Co-Cr) alloys made by casting and selective laser melting (SLM). MATERIALS AND METHODS. In this in-vitro experimental study, two sample groups were prepared, with one group comprising of 10 Co-Cr metal frameworks fabricated by SLM method and the other of 10 Co-Cr metal frameworks fabricated by lost wax cast method with the dimensions of $0.5{\times}3{\times}25\;mm$ (following ISO standard 9693). Porcelain with the thickness of 1.1 mm was applied on a $3{\times}8-mm$ central rectangular area of each sample. Afterwards, bond strengths of the samples were assessed with a Universal Testing Machine. Statistical analysis was performed with Kolmogorov-Smirnov test and T-test. RESULTS. Bond strength in the conventionally cast group equaled $74.94{\times}16.06\;MPa$, while in SLM group, it equaled $69.02{\times}5.77\;MPa$. The difference was not statistically significant ($P{\leq}.05$). CONCLUSION. The results indicated that the bond strengths between ceramic and Co-Cr alloys made by casting and SLM methods were not statistically different.

      • KCI등재

        Effect of GLUMA desensitizer on the retention of full metal crowns cemented with Rely X U200 self-adhesive cement.

        Shirin Lawaf,Ezatallah Jalalian,Roshanak Roshan,Arash Azizi 대한치과보철학회 2016 The Journal of Advanced Prosthodontics Vol.8 No.5

        PURPOSE. Considering the importance of retention in the success and long-term clinical service of fixed partial dentures (FPDs) as well as the existing controversy regarding the effect of GLUMA desensitizer on the retention of full metal crowns cemented with RelyX U200 self-adhesive cement, this study aimed to assess the effect of GLUMA desensitizer on the retention of full metal crowns cemented using RelyX U200. MATERIALS AND METHODS. In this experimental study, 20 sound human premolars were prepared; a 0.5 mm chamfer finish line was prepared above the cementoenamel junction. The teeth were randomly assigned to two groups: a desensitizer group (n = 10, treated with GLUMA desensitizer) and a control (n = 10, no surface treatment). Full metal crowns were fabricated of base metal alloy and had a ring. All crowns were cemented with RelyX U200 and subjected to retention test by using a universal testing machine. The data were analyzed using SPSS version 20 and independent t-test. RESULTS. The mean tensile bond strength was significantly higher in the GLUMA desensitizer group (230.63 ± 63.8 N) compared to the control group (164.45 ± 39.3 N) (P≤.012). CONCLUSION. GLUMA desensitizer increases the tensile bond strength of RelyX U200 self-adhesive cement to dentin.

      • KCI등재

        Comparison of the bond strength of ceramics to Co-Cr alloys made by casting and selective laser melting

        Shirin Lawaf,Shahbaz Nasermostofi,Mahtasadat Afradeh,Arash Azizi 대한치과보철학회 2017 The Journal of Advanced Prosthodontics Vol.9 No.1

        PURPOSE. Considering the importance of metal-ceramic bond, the present study aimed to compare the bond strength of ceramics to cobalt-chrome (Co-Cr) alloys made by casting and selective laser melting (SLM). MATERIALS AND METHODS. In this in-vitro experimental study, two sample groups were prepared, with one group comprising of 10 Co-Cr metal frameworks fabricated by SLM method and the other of 10 Co-Cr metal frameworks fabricated by lost wax cast method with the dimensions of 0.5 × 3 × 25 mm (following ISO standard 9693). Porcelain with the thickness of 1.1 mm was applied on a 3 × 8-mm central rectangular area of each sample. Afterwards, bond strengths of the samples were assessed with a Universal Testing Machine. Statistical analysis was performed with Kolmogorov-Smirnov test and T-test. RESULTS. Bond strength in the conventionally cast group equaled 74.94 ± 16.06 MPa, while in SLM group, it equaled 69.02 ± 5.77 MPa. The difference was not statistically significant (P ≤ .05). CONCLUSION. The results indicated that the bond strengths between ceramic and Co-Cr alloys made by casting and SLM methods were not statistically different.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼