http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Properties of Chemical Beam Epitaxy grown GaAs0.995N0.005 homo-junction solar cell
Boussairi Bouzazi,Kenichi Nishimura,Hidetoshi Suzuki,Nobuaki Kojima,Yoshio Ohshita,Masafumi Yamaguchi 한국물리학회 2010 Current Applied Physics Vol.10 No.2
The minority carrier diffusion length in Chemical Beam Epitaxy (CBE) grown GaAs0.995N0.005 based homojunction solar cell was estimated and found to be L = 0.08 lm. In addition, the majority carrier traps in Nvarying unintentionally doped p-type GaAsN samples grown by CBE were investigated using Deep Level Transient Spectroscopy (DLTS) technique. Five hole traps, HC1–HC5, were detected, where HC2 and HC5coexist in all samples. These two hole traps were suggested to be a N-related defect and the double donor state of EL2, respectively.
Cranioplasty with Custom-made Artificial Bone after Resection of Multilobular Bone Tumor in a Dog
최성진,Muneki Honnami,I-Li Liu,Kenichi Yamamoto,Shinsuke Ohba,Ryosuke Echigo,Shigeki Suzuki,Ryouhei Nishimura,Ung-il Chung,Nobuo Sasaki,Manabu Mochizuki 한국임상수의학회 2014 한국임상수의학회지 Vol.31 No.1
A 7-year-old spayed female Welsh corgi presented with a mass of the skull. The mass was diagnosed asmultilobular bone tumor and surgically removed. To treat a large bone defect after the tumor removal, custom-madeartificial bone fabricated by a 3-dimensional ink-jet printer was implanted in the defect. Follow-up computed tomographyevaluation was performed for 4.3 years. The implant was well integrated with the skull and had covered the largebone defect during the follow-up period. Gradual degradation of the implant began 6 weeks after surgery. It providesan additional option for the treatment of large bone defect.
Next Generation HVAC System for Office Buildings
Yasuo Takagi,Kenzo Yonezawa,Nobutaka Nishimura,Yuuichi Hanada,Kenichi Yamazaki 제어로봇시스템학회 2009 제어로봇시스템학회 국제학술대회 논문집 Vol.2009 No.8
The new air-conditioning control method for the energy saving of buildings is proposed. The method ismainly focused on the compatibility of energy savings and comfort. The energy saving is achieved through the optimal operation of HVAC (Heating, Ventilating and air-conditioning) system, manipulating the supplying airflow temperatures to the rooms, room temperatures and the humidity. The comfort is kept by the index (PMV: Predicted Mean Vote) that comprises temperature, humidity, radiation temperature, wind velocity and so on. In order to find the HVAC system operation conditions that satisfy the comfort and energy saving at the same time, very large-scale nonlinear programming with nonlinear constraints must be solved on real time basis. To make the programming of the system practical, the driving function loaded onto a control computer is introduced. The function is made by the spline-interpolation to achieve calculation stable and adaptation to various HVAC operation modes.