http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Measurement of the Resonance Integral for the 115In(n,g)116In Reaction
Jungran Yoon,Taeik Ro,Katsuhei Kobayashi,Samyol Lee,Shuji Yamamoto 한국물리학회 2004 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.44 No.4
The resonance integral of the 115In(n, )116In reaction has been measured by using the Kyoto University Reactor (KUR) of the Research Reactor Institute, Kyoto University (KURRI), which has a 1/E standard neutron spectrum eld. The activation method was employed to measure the resonance integral. A high-purity Ge (HPGe) detector was used to measure the -rays from the irradiated 115In sample and the 197Au monitor wire. A ux monitor wire, where was a Au/Al alloy wire, was irradiated together with the In/Al alloy sample to measure the neutron ux at the irradiation position. The resonance integral was obtained relative to the reference value (1550 28 b) for the 197Au(n, )198Au reaction. The current resonance integral was obtained as 3275 134 b. Our previous result (dierential data) obtained by using a time-of- ight method with a linac is close to the current result, within the experimental error. The previous measurements, the results evaluated in ENDF/B-VI, and Mughabghab's data are also in good agreement with the current result within the experimental error. However, the JENDL-3.3 and the JEF-2.2 results are a little lower.