http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Kareem Ali Jasim,Haider Sahi Hussein,Shaymaa Hashim Aneed,Ebtisam Mohammed Taqi Salman 한국재료학회 2024 한국재료학회지 Vol.34 No.6
In this study, four different samples of Se60Ge40-xBix chalcogenides glasses were synthesized by heating the melt for 18 h in vacuum Pyrex ampoules (under a 10-4 Torre vacuum), each with a different concentration (x = 0, 10, 15, and 20) of high purity starting materials. The results of direct current (DC) electrical conductivity measurements against a 1,000/T plot for all chalcogenide samples revealed two linear areas at medium and high temperatures, each with a different slope and with different activation energies (E1 and E2). In other words, these samples contain two electrical conduction mechanisms: a localized conduction at middle temperatures and extended conduction at high temperatures. The results showed the local and extended state parameters changed due to the effective partial substitution of germanium by bismuth. The density of extended states N(Eext) and localized states N(Eloc) as a function of bismuth concentration was used to gauge this effect. While the density of the localized states decreased from 1.6 × 1014 to 4.2 × 1012 (ev-1 cm-3) as the bismuth concentration increased from 0 to 15, the density of the extended states generally increased from 3.552 × 1021 to 5.86 × 1021 (ev-1 cm-3), indicating a reduction in the mullet’s randomness. This makes these alloys more widely useful in electronic applications due to the decrease in the cost of manufacturing.
Kareem Ali Jasim,Riyam Abd Al-Zahra Fadil,Kassim Mahdi Wadi,Auday Hattem Shaban 한국재료학회 2023 한국재료학회지 Vol.33 No.9
This study focuses on how the partial substitution of copper by nickel nanoparticles affects the electrical and structural properties of the Bi2Ba2Ca2Cu2.9Ni0.1O10+δ, Bi2Ba2Ca2Cu2.8Ni0.2O10+δ and Bi2Ba2Ca2Cu2.6Ni0.4O10+δ compounds. Approximate values of crystallization size and crystallization percentage for the three compounds were calculated using the Scherer, modified Scherer, and Williamson-Hall methods. A great similarity was observed in the crystal size values from the Scherer method, 243.442 nm, and the Williamson-Hall method, 243.794 nm for the second sample. At the same time this sample exhibited the highest crystal size value for the three methods. In the examination of electrical properties, the sample with 0.1 partial substitution, Bi2Ba2Ca2Cu2.9Ni0.1O10+δ was determined to be the best with a critical temperature of 100 K and an energy gap of 6.57639 × 10-21 MeV. Using the SEM technique to analyze the structural morphology of the three phases, it was discovered that the size of the granular forms exceeds 25 nm. It was determined that the samples’ shapes alter when nickel concentration rises. The patterns that reveal the distribution of the crystal structure also exhibit clear homogeneity.
Oncovascular Surgery and the Making of the Oncovascular Surgeon
Kareem Sallam,Hussein Khairy 대한혈관외과학회 2019 Vascular Specialist International Vol.35 No.4
Patients diagnosed with tumors that are located in vicinity of the major axial vessels are inconsistently managed because they are often considered unresectable. The management of these patients remains at the periphery of various established sub-specialties that are prevalent under the current medical specialty. These patients are required to be treated by an oncovascular surgeon. This article discusses some key points in understanding the reasons for establishing a specialty branch, oncovascular surgery, to treat complex tumors with vessel invasion. This article also reviews important issues about leadership and how to train and educate oncovascular surgeons.
Spinal Robotics in Adult Spinal Deformity Surgery: A Systematic Review
Kareem Khalifeh,Nolan J. Brown,Zach Pennington 대한척추신경외과학회 2024 Neurospine Vol.21 No.1
Spinal robotics have the potential to improve the consistency of outcomes in adult spinal deformity (ASD) surgery. The objective of this paper is to assess the accuracy of pedicle and S2 alar-iliac (S2AI) screws placed with robotic guidance in ASD patients. PubMed Central, Google Scholar, and an institutional library database were queried until May 2023. Articles were included if they described ASD correction via robotic guidance and pedicle and/or S2AI screw accuracy. Articles were excluded if they described pediatric/adolescent spinal deformity or included outcomes for both ASD and non-ASD patients without separating the data. Methodological quality was assessed using the Newcastle-Ottawa scale. Primary endpoints were pedicle screw accuracy based on the Gertzbein-Robbins Scale and self-reported accuracy percentages for S2AI screws. Data were extracted for patient demographics, operative details, and perioperative outcomes and assessed using descriptive statistics. Five studies comprising 138 patients were included (mean age 66.0 years; 85 females). A total of 1,508 screws were inserted using robotic assistance (51 S2AI screws). Two studies assessing pedicle screws reported clinically acceptable trajectory rates of 98.7% and 96.0%, respectively. Another study reported a pedicle screw accuracy rate of 95.5%. Three studies reported 100% accuracy across 51 total S2AI screws. Eight total complications and 4 reoperations were reported. Current evidence supports the application of robotics in ASD surgery as safe and effective for placement of both screw types. However, due to the paucity of data, a comprehensive assessment of its incremental benefit over other techniques cannot be made. Further work using expanded cohorts is merited.
Preparation and Structure Properties of LaBa2Cu2O9, LaBa2CaCu3O12 and LaBa2Ca2Cu5O15 Perovskites
Kareem Ali Jasim,Hind Abdulmajeed Mahdi,Rafah Ismael Noori,Marwa Ayad Abdulmajeed 한국재료학회 2023 한국재료학회지 Vol.33 No.9
In this study we examine variations in the structure of perovskite compounds of LaBa2Cu2O9, LaBa2CaCu3O12 and LaBa2Ca2Cu5O15 synthesized using the solid state reaction method. The samples’ compositions were assessed using X-ray fluorescence (XRF) analysis. The La: Ba: Ca: Cu ratios for samples LaBa2Cu2O9, LaBa2CaCu3O12 and LaBa2Ca2Cu5O15 were found by XRF analysis to be around 1:2:0:2, 1:2:1:3, and 1:2:2:5, respectively. The samples’ well-known structures were then analyzed using X-ray diffraction. The three samples largely consist of phases 1202, 1213, and 1225, with a trace quantity of an unknown secondary phase, based on the intensities and locations of the diffraction peaks. According to the measured parameters a, b, and c, every sample has a tetragonal symmetry structure. Each sample’s mass density was observed to alter as the lead oxide content rose. Scanning electron microscope (SEM) images of the three phases revealed that different Ca-O and Cu-O layers can cause different grain sizes, characterized by elongated thin grains, without a preferred orientation.
Kareem Ali Jasim,Chaiar Abdeen Zaynel Saleh,Alyaa Hamid Ali Jassim 한국재료학회 2024 한국재료학회지 Vol.34 No.1
In this investigation, samples of the chemical (Hg1-xPbxBa2Ca1.8Mg0.2Cu3O8+δ) were prepared utilizing a solid-state reaction technique with a range of lead concentrations (x = 0.0, 0.05, 0.10, and 0.20). Specimens were pressed at 8 tons per square centimeter and then prepared at 1,138 K in the furnace. The crystalline structure and surface topography of all samples were examined using X-ray diffraction (XRD) and atomic force microscopy (AFM). X-ray diffraction results showed that all of the prepared samples had a tetragonal crystal structure. Also, the results showed that when lead was partially replaced with mercury, an increase in the lead value impacted the phase ratio, and lattice parameter values. The AFM results likewise showed excellent crystalline consistency and remarkable homogeneity during processing. The electrical resistivity was calculated as a function of temperature, and the results showed that all samples had a contagious behavior, as the resistivity decreased with decreasing temperature. The critical temperature was calculated and found to change, from 102, 96, 107, and 119 K, when increasing the lead values in the samples from 0.0 to 0.05, 0.10, and 0.20, respectively.
Analysis and performance of offshore platforms in hurricanes
Kareem, Ahsan,Kijewski, Tracy,Smith, Charles E. Techno-Press 1999 Wind and Structures, An International Journal (WAS Vol.2 No.1
Wind effects are critical considerations in the design of topside structures, overall structural systems, or both, depending on the water depth and type of offshore platform. The reliable design of these facilities for oil fields in regions of hostile environment can only be assured through better understanding of the environmental load effects and enhanced response prediction capabilities. This paper summarizes the analysis and performance of offshore platforms under extreme wind loads, including the quantification of wind load effects with focus on wind field characteristics, steady and unsteady loads, gust loading factors, application of wind tunnel tests, and the provisions of the American Petroleum Institute Recommended Practice 2A - Working Stress Design (API RP 2A-WSD) for the construction of offshore structures under the action of wind. A survey of the performance of platforms and satellite structures is provided, and failure mechanisms concerning different damage scenarios during Hurricane Andrew are examined. Guidelines and provisions for improving analysis and design of structures are addressed.