Concrete filled double skin tubular members subjected to bending
Kojiro Uenaka,Hiroaki Kitoh,Keiichiro Sonoda 국제구조공학회 2008 Steel and Composite Structures, An International J Vol.8 No.4
A concrete filled double skin tubular (called CFDST in abbreviation) member consists of two concentric circular steel tubes and filled concrete between them. Purpose of this study is to investigate their bending characteristics experimentally. The two test parameters of the tubes considered were an inner-to-outer diameter ratio and a thickness-diameter ratio. As a result, their observed failure modes were controlled by tensile cracking or local buckling of the outer tube. Discussion is focused on the confinement effect on the filled concrete due to the both tubes and also the influence of the inner-to-outer diameter ratios on their deformability and load carrying capacity.