http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
한지훈,김동주,전중환,장홍희,구자민,김은정,이효종,연성찬 한국동물자원과학회 2004 한국축산학회지 Vol.46 No.1
This study was performed to investigate the behavioral characteristics of Hanwoo(Bos taurus coreanae) cows and their calves. Four cows and their calves were placed in pens. The behaviors of each cow and calf were recorded using a time lapse VCR from 07:00 h to 18:00 h for 6 days and were analyzed using the scan point sampling method. The cow's behaviors in order of frequency were LD(lying down, 25%), ST(standing, 23%), EA(eating, 13%), LR(lying down rumination, 10%) and SR(standing rumination, 7%). The cows spent less than 3% of their time PG(pairwise grooming) and SF(sniffing). The calves mainly showed LD(52%), ST(28%), LF(lying flat, 4%), EA(3%) and WA(walking, 3%). The calves spent less than 2% of their time SF(sniffing) and SUK(sucking). The behavioral patterns of cows and calves at 07:00 h, 12:00 h and 18:00 h were different, especially in ST and LD.
Moon, J.S.,Koo, H.C.,Joo, Y.S.,Jeon, S.H.,Hur, D.S.,Chung, C.I.,Jo, H.S.,Park, Y.H. American Dairy Science Association 2007 Journal of dairy science Vol.90 No.5
The somatic cell count (SCC) is one of the international standards for monitoring milk quality, and it is a useful indicator of mastitis. The current reference method for determining the SCC in raw milk is direct microscopic analysis, but this method requires well-trained staff to maintain its accuracy and reproducibility. To overcome these inconveniences, we developed a portable system (the C-reader system) that utilizes the capillary flow of a microfluidic chamber by surface modification of the hydrophilicity. The microfluidic technology of disposable microchips allows for low consumption of reagents, and a combination of ready-to-use reagents makes the daily work easier. The repeatability test of the C-reader using 10 composite bovine milk samples satisfied the recommended values for SCC equipment. In addition, an acceptable accuracy level of the natural logarithmic-transformed SCC [ln(SCC/1,000):+/-0.059 to 0.112] was achieved using composite raw milk samples and various somatic cell standard solutions from the American Eastern Laboratory and the Korean National Veterinary Research and Quarantine Service. After testing 875 composite milk samples, the C-reader showed a high correlation coefficient (R<SUP>2</SUP>0.935 to 0.964) and a low mean difference value in log-transformed SCC (-0.088 to 0.004) compared with 3 automatic commercialized somatic cell counters (Fossomatic 4000, Somacount 150, and Somascope). In conclusion, the C-reader system is a new, easy-to-use automatic on-farm method with acceptable repeatability and accuracy for measuring SCC in large dairies and smaller laboratories.
Park, K.S.,Han, S.H.,Kie, J.H.,Nam, K.H.,Lee, M.J.,Lim, B.J.,Kwon, Y.E.,Kim, Y.L.,An, S.Y.,Kim, C.H.,Doh, F.M.,Koo, H.M.,Oh, H.J.,Kang, S.W.,Choi, K.H.,Jeong, H.J.,Yoo, T.H. W. B. Saunders Co ; Centrum Philadelphia 2014 Human pathology Vol.45 No.2
Pathologic features can provide valuable information for determining prognosis in IgA nephropathy (IgAN). However, it is uncertain whether the Oxford classification, a new classification of IgAN, can predict renal outcome better than previous ones. We conducted a retrospective cohort study in 500 patients with biopsy-proven IgAN between January 2002 and December 2010 to compare the ability of the Haas and the Oxford classifications to predict renal outcome. Primary outcome was a doubling of the baseline serum creatinine concentration (D-SCr). During a mean follow-up of 68months, 52 (10.4%) and 35 (7.0%) developed D-SCr and end-stage renal disease, respectively. There were graded increases in the development of D-SCr in the higher Haas classes. In addition, the primary endpoint of D-SCr occurred more in patients with the Oxford M and T lesions than those without such lesions. In multivariate Cox regression analyses, the Haas class V (HR, 12.19; P=.002) and the Oxford T1 (hazard ratio [HR], 6.68; P<.001) and T2 (HR, 12.16; P<.001) lesions were independently associated with an increased risk of reaching D-SCr. Harrell's C index of each multivariate model with the Haas and the Oxford classification was 0.867 (P=.015) and 0.881 (P=.004), respectively. This was significantly higher than that of model with clinical factors only (C=0.819). However, there was no difference in C-statistics between the 2 models with the Haas and the Oxford classifications (P=.348). This study suggests that the Haas and the Oxford classifications are comparable in predicting progression of IgAN.
崔埈赫,李秉柱,元哲昊,具成謨,金明南,金昶秀,孫炳基,曺辰鎬 경북대학교 센서기술연구소 1995 센서技術學術大會論文集 Vol.6 No.1
Electrolyte analyzer is one of widely used instrument in the hospitals and laboratories. In this paper, a desktop electrolyte analyzer which can detect and display both ion concentrations of hydrogen and sodium in the solution using ISFET is developed. We designed hardware of the system including signal-processing circuit for multiple sensor and flow system consist of a sample chamber unit and 12 actuators. For the efficient control of the system, 2-point calibration, measurement and washing algorithms are also developed. We compare the pH, pNa values measured by the developed system with those measured by reference system and verified the performance.
권계철,구선회,박종우 충남대학교 의과대학 지역사회의학연구소 1995 충남의대잡지 Vol.22 No.2
Hepatitis C infection is known to be a very serious disease and high risk of transmission by nonparenteral route. But immunoassay method was less sensitive and specific than that of PCR method. The extraction of RNA is largely important to amplification of hepatitis C virus. This study was performed to evaluate the new reagent, Tri-reagent, which was used to extract RNA compared to the conventional method : heat and phenol-chloroform extraction method. The results were as follows 1. Mean concentration of extracted RNA by Tri-reagent method was 6135.3 mg/ml. 2. Mean concentration of extracted RNA by phenol chloroform method was 419.0 mg/ml. 3. Mean concentration of extracted RNA by heat method was 691.7 mg/ml. 4. PCR products by Tri-reagent were the most distinctive than those by other two methods The mean concentration of extracted RNA by Tri-reagent method was much higher than that of RNA by phenol - chloroform and heat method. In conclusion, the usage of Tri-reagent was rapid and succesful to extract of RNA compared to the conventional extraction methods.
Yu, K‐,H.,Hong, K‐,S.,Lee, B‐,C.,Oh, M‐,S.,Cho, Y‐,J.,Koo, J‐,S.,Park, J‐,M.,Bae, H‐,J.,Han, M‐,K.,Ju, Y‐,S.,Kang, D‐,W.,Appelros, P. Blackwell Publishing Ltd 2011 Acta neurologica Scandinavica Vol.123 No.5
<P>Yu K‐H, Hong K‐S, Lee B‐C, Oh M‐S, Cho Y‐J, Koo J‐S, Park J‐M, Bae H‐J, Han M‐K, Ju Y‐S, Kang D‐W, Appelros P, Norrving B, Terent A. Comparison of 90‐day case‐fatality after ischemic stroke between two different stroke outcome registries using propensity score matching analysis. Acta Neurol Scand: 2011: 123: 325–331. © 2010 John Wiley & Sons A/S.</P><P><B>Background – </B> It has not been clarified whether the disparity in ischemic stroke outcome between populations is caused by ethnic and geographic differences or by variations in case mix. Propensity score matching (PSM) analysis can overcome some analytical problems but is rarely used in stroke outcome research. This study was to compare the ischemic stroke case‐fatality between two PSM cohorts of Sweden and Korea.</P><P><B>Methods – </B> Prognostic variables related to baseline characteristics and stroke care were included in our PSM model. Then, we selected 7675 Swedish and 1220 Korean patients with ischemic stroke from each stroke registers and performed one‐to‐one matching based on propensity scores of each patient.</P><P><B>Results – </B> After PSM, all measured variables were well balanced in 1163 matched subjects, and the 90‐day case‐fatality was identical 6.2% (HR 0.997, 95%CI 0.905–1.099) in Sweden and Korea.</P><P><B>Conclusions – </B> No difference is found in the 90‐day case‐fatality in propensity score‐matched Swedish and Korean patients with ischemic stroke.</P>
Mouse Mammary Epithelial Cell에서 Retrovirus Vector를 이용한 Human Lactadherin 유전자의 유도적 발현
권모선,구본철,정병현,염행철,박창식,김태완 충남대학교 형질전환복제돼지연구센터 2004 논문집 Vol. No.8
Lactadherin (formerly known as BA46), a major glycoprotein of the human milk fat globule membrane, is abundant in human breast milk and breast carcinomas and may prevent symptomatic rotavirus infections. In this study, under the control of tissue specific and hormonal inducible mouse whey acidic protein (WAP) promoter, the expression pattern of lactadherin (Ltd) in lactogenic hormone - dependent mouse mammary epithelial cell line HCll were tested. pLNWLtd construct containing 2.4 kilobases of the WAP promoter and 1.5 kilobases of human lactadherin gene was stably transfered into HCll cells using retroviral vector system. Integration and expression level of the transgene was estimated using PCR and RT-PCR, respectively. Prominent induction of Ltd gene under the WAP promoter was accomplished in the presence of insulin, hydrocortisone and prolactin. Compared to the control (cells cultured with insulin alone), however we observed that the WAP promoter was leaky. These data indicate that futher studies are needed in finding an appropriate promoter other than WAP promoter because of its leakiness.