RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        Temperature distribution in a full-scale steel framed building subject to a natural fire

        František Wald,Magdalena Chladná,David Moore,Aldina Santiago,Tom Lennon 국제구조공학회 2006 Steel and Composite Structures, An International J Vol.6 No.2

        Current fire design codes for determining the temperature within the structural elements that form part of a complete building are based on isolated member tests subjected to the standard fire. However, the standard time-temperature response bears little relation to real fires and doesn’t include the effects of differing ventilation conditions or the influence of the thermal properties of compartment linings. The degree to which temperature uniformity is present in real compartments is not addressed and direct flame impingement may also have an influence, which is not considered. It is clear that the complex thermal environmental that occurs within a real building subject to a natural fire can only be addressed using realistic full-scale tests. To study global structural and thermal behaviour, a research project was conducted on the eight storey steel frame building at the Building Research Establishment’s Cardington laboratory. The fire compartment was 11 m long by 7 m wide. A fire load of 40 kg/m2 was applied together with 100% of the permanent actions and variable permanent actions and 56% of live actions. This paper summarises the experimental programme and presents the time-temperature development in the fire compartment and in the main supporting structural elements. Comparisons are also made between the test results and the temperatures predicted by the structural fire Eurocodes.

      • KCI등재후보

        Temperature of Connections During Fire on Steel Framed Building

        Jiří Chlouba,František Wald,Zdeněk Sokol 한국강구조학회 2009 International Journal of Steel Structures Vol.9 No.1

        To study the global structural and thermal behaviour of buildings in fire, a research project was conducted including a fullscale test on a three storey steel frame building at Mittal Steel Ostrava before demolition. The main goal of the experiment was to verify the method for predicting joint temperatures and to improve it for the cooling phase. The fire compartment extending over a floor area of 24 m2 was built on the second floor. The fire load was 140 kg/m2 of wood and the ventilation was limited to an opening of 1,400×1,970 mm. This paper presents the time-temperature curves showing the development of the fire in the compartment and in the primary and secondary beams and its header plate connections. Comparisons are made between the test results and the temperatures predicted by the structural Eurocodes. The sensitivity of the connection behaviour to the estimated temperatures and associated degradation in material properties during the fire is demonstrated. To study the global structural and thermal behaviour of buildings in fire, a research project was conducted including a fullscale test on a three storey steel frame building at Mittal Steel Ostrava before demolition. The main goal of the experiment was to verify the method for predicting joint temperatures and to improve it for the cooling phase. The fire compartment extending over a floor area of 24 m2 was built on the second floor. The fire load was 140 kg/m2 of wood and the ventilation was limited to an opening of 1,400×1,970 mm. This paper presents the time-temperature curves showing the development of the fire in the compartment and in the primary and secondary beams and its header plate connections. Comparisons are made between the test results and the temperatures predicted by the structural Eurocodes. The sensitivity of the connection behaviour to the estimated temperatures and associated degradation in material properties during the fire is demonstrated.

      • KCI등재후보

        Design of corrugated sheets exposed to fire

        Zden k Sokol,František Wald,Petra Kallerová 국제구조공학회 2008 Steel and Composite Structures, An International J Vol.8 No.3

        This paper presents results of fire tests on corrugated sheets used as load bearing structure of roofs of industrial buildings. Additional tests of bolted sheet connections to the supporting structure at ambient and elevated temperatures are described. Three connection types were tested and their resistance, stiffness and deformation capacity was evaluated. Finite element simulations of the corrugated sheet based on the experimental observations are briefly described and design models are presented.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼