        Correlation between gray values in cone-beam computed tomography and histomorphometric analysis

        Anbiaee Najmeh,Shafieian Reihaneh,Shiezadeh Farid,Shakeri Mohammadtaghi,Naqipour Fatemeh 대한영상치의학회 2022 Imaging Science in Dentistry Vol.52 No.4

        Purpose: The aim of this study was to analyze the relationships between bone density measurements obtained using cone-beam computed tomography (CBCT) and morphometric parameters of bone determined by histomorphometric analysis. Materials and Methods: In this in vivo study, 30 samples from the maxillary bones of 7 sheep were acquired using a trephine. The bone samples were returned to their original sites, and the sheep heads were imaged using CBCT. On the CBCT images, gray values were calculated. In the histomorphometric analysis, the total bone volume, the trabecular bone volume (referred to simply as bone volume), and the trabecular thickness were assessed. Results: Statistical testing showed significant correlations between CBCT gray values and total bone volume (r = 0.537, P = 0.002), bone volume (r = 0.672, P<0.001), and trabecular thickness (r = 0.692, P<0.001), as determined via the histomorphometric analysis. Conclusion: The results indicate a significant and acceptable association between CBCT gray values and bone volume, suggesting that CBCT may be used in bone densitometry.

      • SCOPUSKCI등재

        Correlation between gray values in cone-beam computed tomography and histomorphometric analysis

        Najmeh, Anbiaee,Reihaneh, Shafieian,Farid, Shiezadeh,Mohammadtaghi, Shakeri,Fatemeh, Naqipour Korean Academy of Oral and Maxillofacial Radiology 2022 Imaging Science in Dentistry Vol.52 No.-

        Purpose: The aim of this study was to analyze the relationships between bone density measurements obtained using cone-beam computed tomography (CBCT) and morphometric parameters of bone determined by histomorphometric analysis. Materials and Methods: In this in vivo study, 30 samples from the maxillary bones of 7 sheep were acquired using a trephine. The bone samples were returned to their original sites, and the sheep heads were imaged using CBCT. On the CBCT images, gray values were calculated. In the histomorphometric analysis, the total bone volume, the trabecular bone volume (referred to simply as bone volume), and the trabecular thickness were assessed. Results: Statistical testing showed significant correlations between CBCT gray values and total bone volume (r =0.537, P =0.002), bone volume (r =0.672, P<0.001), and trabecular thickness (r =0.692, P<0.001), as determined via the histomorphometric analysis. Conclusion: The results indicate a significant and acceptable association between CBCT gray values and bone volume, suggesting that CBCT may be used in bone densitometry.

      • SCOPUSKCI등재

        Human embryos derived from first polar body nuclear transfer exhibit comparatively abnormal morphokinetics during development

        Leila Heydari,Mohammad Ali Khalili,Azam Agha Rahimi,Fatemeh Shakeri The Korean Society for Reproductive Medicine 2023 Clinical and Experimental Reproductive Medicine Vol.50 No.3

        Objective: Reconstructed oocytes after polar body genome transfer constitute a potential therapeutic option for patients with a history of embryo fragmentation and advanced maternal age. However, the rescue of genetic material from the first polar body (PB1) through introduction into the donor cytoplasm is not yet ready for clinical application. Methods: Eighty-five oocytes were obtained following in vitro maturation (IVM) and divided into two groups: PB1 nuclear transfer (PB1NT; n=54) and control (n=31). Following enucleation and PB1 genomic transfer, PB1 fusion was assessed. Subsequently, all fused oocytes underwent intracytoplasmic sperm injection (ICSI) and were cultured in an incubator under a time-lapse monitoring system to evaluate fertilization, embryonic morphokinetic parameters, and cleavage patterns. Results: Following enucleation and fusion, 77.14% of oocytes survived, and 92.59% of polar bodies (PBs) fused. However, the normal fertilization rate was lower in the PB1NT group than in the control group (56.41% vs. 92%, p=0.002). No significant differences were observed in embryo kinetics between the groups, but a significant difference was detected in embryo developmental arrest after the four-cell stage, along with abnormal cleavage division in the PB1NT group. This was followed by significant between-group differences in the implantation potential rate and euploidy status. Most embryos in the PB1NT group had at least one abnormal cleavage division (93.3%, p=0.001). Conclusion: Fresh PB1NT oocytes successfully produced normal zygotes following PB fusion and ICSI in IVM oocytes. However, this was accompanied by low efficiency in developing into cleavage embryos, along with an increase in abnormal cleavage patterns.