        Noise Exposure Assessment in a Dental School

        Choosong, Thitiworn,Kaimook, Wandee,Tantisarasart, Ratchada,Sooksamear, Puwanai,Chayaphum, Satith,Kongkamol, Chanon,Srisintorn, Wisarut,Phakthongsuk, Pitchaya Occupational Safety and Health Research Institute 2011 Safety and health at work Vol.2 No.4

        Objectives: This cross-sectional study was performed in the Dental School of Prince of Songkla University to ascertain noise exposure of dentists, dental assistants, and laboratory technicians. A noise spectral analysis was taken to illustrate the spectra of dental devices. Methods: A noise evaluation was performed to measure the noise level at dental clinics and one dental laboratory from May to December 2010. Noise spectral data of dental devices were taken during dental practices at the dental services clinic and at the dental laboratory. A noise dosimeter was set following the Occupational Safety and Health Administration criteria and then attached to the subjects' collar to record personal noise dose exposure during working periods. Results: The peaks of the noise spectrum of dental instruments were at 1,000, 4,000, and 8,000 Hz which depended on the type of instrument. The differences in working areas and job positions had an influence on the level of noise exposure (p < 0.01). Noise measurement in the personal hearing zone found that the laboratory technicians were exposed to the highest impulsive noise levels (137.1 dBC). The dentists and dental assistants who worked at a pedodontic clinic had the highest percent noise dose (4.60 ${\pm}$ 3.59%). In the working areas, the 8-hour time-weighted average of noise levels ranged between 49.7-58.1 dBA while the noisiest working area was the dental laboratory. Conclusion: Dental personnel are exposed to noise intensities lower than occupational exposure limits. Therefore, these dental personnel may not experience a noise-induced hearing loss.

      • SCOPUSKCI등재

        Urinary 1-Hydroxypyrene Levels in Workers Exposed to Polycyclic Aromatic Hydrocarbon from Rubber Wood Burning

        Choosong, Thitiworn,Phakthongsuk, Pitchaya,Tekasakul, Surajit,Tekasakul, Perapong Occupational Safety and Health Research Institute 2014 Safety and health at work Vol.5 No.2

        Background: Urinary 1-hydroxypyrene (1-OHP) was selected as a biomarker of polycyclic aromatic hydrocarbons (PAHs) to explore the accumulation level in the bodies of workers at rubber smoke sheet factories in southern Thailand. Methods: Spot urine samples were taken from four groups of workers from June 2006 to November 2007. The nonexposure or control groups included habitual cigarette smokers and nonsmokers. The other two groups were workers exposed to particle-bound PAHs from rubber wood smoke and they were nonsmokers. All spot urine samples were analyzed for 1-OHP and creatinine levels. Results: The mean${\pm}$standard deviation urinary 1-OHP in the control group of habitual smokers and the nonsmokers was $0.24{\pm}0.16{\mu}mol/mol$ creatinine and not-detected to $0.14{\mu}mol/mol$ creatinine, respectively. In the workers, the 1-OHP levels on workdays had no significant difference from the 1-OHP levels on the days off. The yearly average 1-OHP level was $0.76{\pm}0.41{\mu}mol/mol$ creatinine whereas the average 1-OHP level during 10 consecutive workdays was $1.06{\pm}0.29{\mu}mol/mol$ creatinine (p > 0.05). Conclusion: The urinary 1-OHP levels of workers exposed to PAHs were high. The accumulation of 1-OHP in the body was not clear although the workers had long working hours with few days off during their working experience. Therefore, a regular day off schedule and rotation shift work during high productive RSS should be set for RSS workers.

      • KCI등재

        Urinary 1-Hydroxypyrene Levels in Workers Exposed to Polycyclic Aromatic Hydrocarbon from Rubber Wood Burning

        Thitiworn Choosong,Pitchaya Phakthongsuk,Surajit Tekasakul,Perapong Tekasakul 한국산업안전보건공단 산업안전보건연구원 2014 Safety and health at work Vol.5 No.2

        Background: Urinary 1-hydroxypyrene (1-OHP) was selected as a biomarker of polycyclic aromatic hydrocarbons (PAHs) to explore the accumulation level in the bodies of workers at rubber smoke sheet factories in southern Thailand. Methods: Spot urine samples were taken from four groups of workers from June 2006 to November 2007. The nonexposure or control groups included habitual cigarette smokers and nonsmokers. The other two groups were workers exposed to particle-bound PAHs from rubber wood smoke and they were nonsmokers. All spot urine samples were analyzed for 1-OHP and creatinine levels. Results: The mean ? standard deviation urinary 1-OHP in the control group of habitual smokers and the nonsmokers was 0.24 ? 0.16 mmol/mol creatinine and not-detected to 0.14 mmol/mol creatinine, respectively. In the workers, the 1-OHP levels on workdays had no significant difference from the 1-OHP levels on the days off. The yearly average 1-OHP level was 0.76 ? 0.41 mmol/mol creatinine whereas the average 1-OHP level during 10 consecutive workdays was 1.06 ? 0.29 mmol/mol creatinine (p > 0.05). Conclusion: The urinary 1-OHP levels of workers exposed to PAHs were high. The accumulation of 1-OHP in the body was not clear although the workers had long working hours with few days off during their working experience. Therefore, a regular day off schedule and rotation shift work during high productive RSS should be set for RSS workers.