An Experimental Verification Study on the Heat Flow Analysis Results of a Tube Furnace
Byungsuk Park,Sangwoon Kwon,Juho Lee,Changhwa Lee 한국방사성폐기물학회 2023 한국방사성폐기물학회 학술논문요약집 Vol.21 No.2
In general, systems are developed by repeatedly performing the processes of design, analysis, manufacturing, and performance testing. In particular, systems with temperature, pressure, and flow rate often utilize computational fluid dynamics tools at the design stage. In this paper, we aim to verify the reliability of the analysis results of Solidworks Flow Simulation, which is widely used in heat flow analysis at the design stage. A tube furnace was manufactured, various experiments were performed, and a study was conducted to compare the analysis results. The details of the experiment are as follows. First, an experiment was conducted in which the heater was heated to 900°C without insulating the exposed part of the tube. The detailed contents of the experiment are as follows; - Heating heater and measuring temperature without supplying flow inside the tube, - Tube flow supply (25°C, 15 lpm air) and heater heating/temperature measurement. Second, an experiment was performed in which the exposed part of the tube was insulated (thickness 50 mm) and the heater was heated to 900°C. The detailed contents of the experiment are as follows; - Insulate the outside of the tube except for the flanges at both ends of the tube, and heat the heater and measure the temperature without supplying flow inside the tube. - Insulate the outside of the tube except for the flanges at both ends of the tube, supply flow rate inside the tube (25°C, 15 lpm air) and measure heater heating/temperature. - Insulate the flange of the flow supply section, heat the heater and measure temperature without supplying flow inside the tube. - Insulate the flange of the flow supply section, heat the supply air (277°C, 15 lpm) and measure the temperature using a heating gun without heating the heater. - Insulate the flange of the flow supply section, supply heated air (277°C, 15 lpm) and measure heater heating/temperature. - Insulate the flange of the flow supply section and measure temperature according to heater heating (900°C) and supply temperature (25°C, 277°C 15 lpm). The following results were derived from the experimental and analysis results. - When the exposed part of the tube is insulated, the temperature inside the tube increases and the steady-state power decreases compared to non-insulated. - In areas with insulation, the temperature error between experiment and analysis results is not large. - When flow rate is supplied, there is a large temperature error in experiment and analysis results. - The temperature change after the center of the heater is not large for a temperature change of 15 lpm flow rate. From these results, it can be seen that Solidworks Flow Simulation has a significant difference from the experimental results when there is a flow rate in the tube. This was thought to be because the flow rate acts as a disturbance, and this cannot be sufficiently accounted for in the analysis. In the future, we plan to check whether there is a way to solve this problem.
A Study on the Design Parameters of the Off-gas Trapping System
Byungsuk Park,Seokmin Hong,Juho Lee,Jaewon Lee,Changhwa Lee 한국방사성폐기물학회 2022 한국방사성폐기물학회 학술논문요약집 Vol.20 No.2
The Korea Atomic Energy Research Institute is developing a nuclide management process that separates high heat, high mobility, and long half-life nuclides that burden the disposal of spent fuel, and disposes of spent fuel by nuclide according to the characteristics of each nuclide. Various offgases (volatile and semi-volatile nuclides) generated in this process must be discharged to the atmosphere below the emission standard, so an off-gas trapping system is required. In this study, we introduce the analysis results of the parameters that affect the design of the off-gas trapping system. The analyzed contents are as follows. The physical quantities of the Cs, Tc/se, and I trapping filters according to the amount of spent nuclear fuel, the maximum exothermic temperature of the Cs trapping filter and the absorbed dose by distance by Cs radioactivity were analyzed according to the amount of spent nuclear fuel. In addition, a three-dimensional CFD (Computational Fluid Dynamics) analysis was performed according to operating parameters by simply modeling the off-gas trapping system, which is easy to modify mechanical design parameters. It is considered that the analysis results will greatly contribute to the development of the off-gas trapping system design requirements.
An Experimental Study on the Heat Flow of Tube Furnace by Air Flow in Tube
Byungsuk Park,Seokmin Hong,Jaewon Lee,Sangwoon Kwon,Juho Lee,Changhwa Lee 한국방사성폐기물학회 2023 한국방사성폐기물학회 학술논문요약집 Vol.21 No.1
In this paper, a basic study was conducted to observe the temperature inside the tube according to the heating temperature of the tube furnace. In a tube furnace, a tube is inserted, and the air space outside the tube is heated to increase the temperature of the gas inside the tube through conduction of the tube. Tube furnaces are widely used in research to capture volatile nuclides. In this case, a volatile nuclide capturing filter is inserted inside the tube, and an appropriate temperature is required to capture it. Since the tube furnace heats the air space outside the tube to the target temperature, a difference from the temperature inside the tube occurs. In particular, if a flow of gas occurs inside the tube, a larger temperature difference may occur. In order to confirm this temperature difference, an experimental device was constructed, and basic data was produced through several experiments. The following studies were conducted to produce data. First, the temperature of the air layer of the heating unit and the temperature inside the tube were measured in real time in the absence of gas flow inside the tube. Second, the temperature of the air layer of the heating unit and the temperature inside the tube were measured in real time while air having a certain temperature was flowing inside the tube. As a result of the experiment, when there is no flow inside the tube, when the heating target temperature is low, the temperature inside the tube is significantly lower than the target temperature, and when the target temperature is high, the temperature inside the tube approaches the target temperature. It was found that when there is about 20°C air flow inside the tube, the temperature inside the tube is significantly lowered even if the heating target temperature is high. In the future, additional research on changing the temperature of the gas flowing inside the tube will be conducted, and the results of this study are expected to greatly contribute to the design of a tube furnace that captures volatile nuclides.
The 3-Dimensional Active Earth Pressure and Load Transfer
( Byungsuk Park ),( Junho Jeong ),( Yunseok Kang ) 대한지질공학회 2019 대한지질공학회 학술발표회논문집 Vol.2019 No.2
In this study, it was experimentally tried to investigate the magnitude and the distribution of 3-dimensional active earth pressure and the magnitude and the influence range of transferred load to the adjacent ground. As results, the 3-dimensional active earth pressure were arrived at the horizontal wall displacements, which was approximately 0.13% of the wall height(h), and the resultant earth pressure was similar to that of Walz/Prager (1978) and Karstedt (1982). The distribution of the 3-dimensional active earth pressure showed that the earth pressure at the top and the bottom of a wall was relatively small, The largest earth pressure was measured at the height of 0.50~0.55h when the aspect ratio was larger than 1.2. The ratio of the 3-dimensional active earth pressure to the 2-dimensional active earth pressure was proposed as a reduction coefficient(a). The amount of the load transferred to adjacent ground was 61.7~81.9%. And the range of load transfer was 0.75~1.29w in the lateral direction, and 0.0~2.0h in the vertical direction when the aspect ratio was 0.1~2.7. The transferred load in horizontal direction was larger than that in vertical direction. The largest load was transferred at the boundary of active wall for both vertical and lateral directions. As the aspect ratio increased, the load transfer in horizontal direction increased gradually. A formula to predict the influence range of load transfer with the width of active wall was suggested for the aspect ratio 0.1 ~1.8.