http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Fault Line Detection Methodology for Four Parallel Lines on the Same Tower
Botong Li,Yongli Li,Chuang Yao 대한전기학회 2014 Journal of Electrical Engineering & Technology Vol.9 No.4
A method for faulted line detection of four parallel lines on the same tower is presented, based on four-summing and double-differential sequences of one terminal current. Four-summing and double-differential sequences of fault current can be calculated using a certain transformation matrix for parameter decoupling of four parallel transmission lines. According to fault boundary conditions, the amplitude and phase characteristics of four-summing and double-differential sequences of fault current is studied under conditions of different types of fault. Through the analysis of the relationship of terminal current and fault current, a novel methodology for fault line detection of four parallel transmission line on the same tower is put forward, which can pick out the fault lines no matter the fault occurs in single line or cross double lines. Simulation results validate that the methodology is correct and reliable under conditions of different load currents, transient resistances and fault locations.
Fault Line Detection Methodology for Four Parallel Lines on the Same Tower
Li, Botong,Li, Yongli,Yao, Chuang The Korean Institute of Electrical Engineers 2014 Journal of Electrical Engineering & Technology Vol.9 No.4
A method for faulted line detection of four parallel lines on the same tower is presented, based on four-summing and double-differential sequences of one terminal current. Four-summing and double-differential sequences of fault current can be calculated using a certain transformation matrix for parameter decoupling of four parallel transmission lines. According to fault boundary conditions, the amplitude and phase characteristics of four-summing and double-differential sequences of fault current is studied under conditions of different types of fault. Through the analysis of the relationship of terminal current and fault current, a novel methodology for fault line detection of four parallel transmission line on the same tower is put forward, which can pick out the fault lines no matter the fault occurs in single line or cross double lines. Simulation results validate that the methodology is correct and reliable under conditions of different load currents, transient resistances and fault locations.