RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        Carotid Artery Stenting and Its Impact on Cognitive Function: A Prospective Observational Study

        Gupta Avinash N,Bhatti Amit A,Shah Mudasir M,Mahajan Niranjan P,Sadana Divya K,Huded Vikram 대한신경중재치료의학회 2020 Neurointervention Vol.15 No.2

        Purpose: Carotid artery stenting (CAS) has evolved as a first-line therapeutic option for carotid revascularization in indicated patients for stroke prevention, but there is still a lack of data on its effect on cognitive function (CF), especially among Indian patients. To determine the effect of CAS on CF and to study the immediate and delayed complications of CAS in Indian patients.Materials and Methods: This was a prospective, observational, single-center study. CF was assessed using Addenbrooke’s cognitive examination version III (ACE) before and 3 months after stenting. The demographic and clinical parameters were also assessed. A follow-up evaluation after 3 months was done to compare CF and to observe the occurrence of any complications.Results: Out of 31 patients, 3 were lost to follow up. There were no immediate or delayed procedure-related complications. There was a statistically significant improvement in overall ACE score and memory before and after stenting. On subgroup analysis of those with and without strokes, there was a significant improvement in visuospatial function and mean ACE score. Those with left CAS had significant improvement in memory, visuospatial, language, and ACE scores than right CAS.Conclusion: CAS was associated with significant improvement in CF in patients.

      • KCI등재후보

        REtrospective Multicenter INdian Study of Derivo Embolization Device (REMIND): Periprocedural Safety

        Niranjan Prakash Mahajan,Mudasir Mushtaq,Amit Bhatti,Sukalyan Purkayastha,Nitin Dange,Mathew Cherian,Vipul Gupta,Vikram Huded 대한신경중재치료의학회 2021 Neurointervention Vol.16 No.3

        Purpose: The treatment of aneurysms with characteristics such as complex morphology, fusiform, blister-like, wide neck, or large size has been revolutionized with the introduction of flow diverters. Though flow diverters have several advantages over coiling, they also have certain important disadvantages such as the lack of immediate protection against rupture, the risk of ischemic stroke, the need for antiplatelet therapy, and long latency for complete effect. The Derivo Embolization Device (DED) is a second-generation self-expanding device that is claimed to be less thrombogenic than conventional devices. We retrospectively evaluated the periprocedural safety and risks associated with the DED across 5 centers in India. Materials and Methods: This is a multicentric, retrospective, observational study of DED, conducted at 5 high volume endovascular therapy centers in India from May 2018 to June 2020. Periprocedural demographic, clinical, and angiographic data were collected from a retrospective review of patient charts. Results: A total of 96 patients, including 56 (58.3%) females, aged between 16–80 years (60±12.7 years) harboring 106 aneurysms were studied. Seven (7.3%) were noted to harbor multiple aneurysms: 6 had 3 aneurysms each, while 1 patient had 5 aneurysms. The following aneurysm characteristics were noted: average size, 9.8±8.2 mm; average neck size, 6.9±8.5 mm; wide-necked (>4 mm), 63 (59.4%); giant (>25 mm), 8 (7.5%); and anterior circulation location, 98 (92.5%). Eighteen (17%) of these were ruptured. Additional balloon angioplasty was performed in 5 (5.2%) patients. Intraprocedural problems were encountered in 3 (3.1%), of which only 1 had clinical implications, the device fish-mouthing with stent thrombosis resulting in a malignant middle cerebral artery territory infarction. The modified Rankin scale at 3 months was worse in 1 patient. Conclusion: DED is a newer generation flow diverter stent with a low periprocedural complication rate.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼