http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Do universal adhesives promote bonding to dentin? A systematic review and meta-analysis
Elkaffas, Ali. A.,Hamama, Hamdi H.H.,Mahmoud, Salah H. The Korean Academy of Conservative Dentistry 2018 Restorative Dentistry & Endodontics Vol.43 No.3
Objectives: The aims of this study were to conduct a systematic review of the microtensile bond strength (${\mu}TBS$) of multi-mode adhesives to dentin and to perform a meta-analysis to assess the significance of differences in the ${\mu}TBS$ of one of the most commonly used universal adhesives (Scotchbond Universal, 3M ESPE) depending on whether the etch-and-rinse or self-etch mode was used. Materials and Methods: An electronic search was performed of MEDLINE/PubMed, ScienceDirect, and EBSCOhost. Laboratory studies that evaluated the ${\mu}TBS$ of multi-mode adhesives to dentin using either the etch-and-rinse or self-etch mode were selected. A meta-analysis was conducted of the reviewed studies to quantify the differences in the ${\mu}TBS$ of Scotchbond Universal adhesive. Results: Only 10 studies fulfilled the inclusion criteria for the systematic review. Extensive variation was found in the restorative materials, testing methodologies, and failure mode in the reviewed articles. Furthermore, variation was also observed in the dimensions of the microtensile testing beams. The meta-analysis showed no statistically significant difference between the etch-and-rinse and self-etch modes for Scotchbond Universal adhesive (p > 0.05). Conclusions: Multi-mode 'universal' adhesives can achieve substantial bonding to dentin, regardless of the used modes (either etch-and-rinse or self-etch).
The effect of preheating resin composites on surface hardness: a systematic review and meta-analysis
Elkaffas, Ali A.,Eltoukhy, Radwa I.,Elnegoly, Salwa A.,Mahmoud, Salah H. The Korean Academy of Conservative Dentistry 2019 Restorative Dentistry & Endodontics Vol.44 No.4
Objectives: This paper presents a systematic review and meta-analysis of the effect of preheating on the hardness of nanofilled, nanoceramic, nanohybrid, and microhybrid resin composites. Materials and Methods: An electronic search of papers on MEDLINE/PubMed, ScienceDirect, and EBSCOhost was performed. Only in vitro studies were included. Non-English studies, case reports, clinical trials, and review articles were excluded. A meta-analysis of the reviewed studies was conducted to quantify differences in the microhardness of the Z250 microhybrid resin composite using the Comprehensive Meta-Analysis software. Results: Only 13 studies met the inclusion criteria for this systematic review. The meta-analysis showed that there were significant differences between the non-preheated and preheated modes for both the top and bottom surfaces of the specimens (p < 0.05). The microhardness of the Z250 resin composite on the top surface in the preheated mode (78.1 ± 2.9) was higher than in the non-preheated mode (67.4 ± 4.0; p < 0.001). Moreover, the microhardness of the Z250 resin composite on the bottom surface in the preheated mode (71.8 ± 3.8) was higher than in the non-preheated mode (57.5 ± 5.7, p < 0.001). Conclusions: Although the results reported in the reviewed studies showed great variability, sufficient scientific evidence was found to support the hypothesis that preheating can improve the hardness of resin composites.
Do universal adhesives promote bonding to dentin? A systematic review and meta-analysis
Ali. A. Elkaffas,Hamdi H. H. Hamama,Hamdi H. H. Hamama,Salah H. Mahmoud 대한치과보존학회 2018 Restorative Dentistry & Endodontics Vol.43 No.3
Objectives: The aims of this study were to conduct a systematic review of the microtensile bond strength (µTBS) of multi-mode adhesives to dentin and to perform a meta-analysis to assess the significance of differences in the µTBS of one of the most commonly used universal adhesives (Scotchbond Universal, 3M ESPE) depending on whether the etch-and-rinse or self�etch mode was used. Materials and Methods: An electronic search was performed of MEDLINE/PubMed, ScienceDirect, and EBSCOhost. Laboratory studies that evaluated the µTBS of multi-mode adhesives to dentin using either the etch-and-rinse or self-etch mode were selected. A meta�analysis was conducted of the reviewed studies to quantify the differences in the µTBS of Scotchbond Universal adhesive. Results: Only 10 studies fulfilled the inclusion criteria for the systematic review. Extensive variation was found in the restorative materials, testing methodologies, and failure mode in the reviewed articles. Furthermore, variation was also observed in the dimensions of the microtensile testing beams. The meta-analysis showed no statistically significant difference between the etch-and-rinse and self-etch modes for Scotchbond Universal adhesive (p > 0.05). Conclusions: Multi-mode ‘universal’ adhesives can achieve substantial bonding to dentin, regardless of the used modes (either etch-and-rinse or self-etch).
The effect of preheating resin composites on surface hardness: a systematic review and meta-analysis
Ali A. Elkaffas,Radwa I. Eltoukhy,Salwa A. Elnegoly,Salah H. Mahmoud 대한치과보존학회 2019 Restorative Dentistry & Endodontics Vol.44 No.4
Objectives This paper presents a systematic review and meta-analysis of the effect of preheating on the hardness of nanofilled, nanoceramic, nanohybrid, and microhybrid resin composites. Materials and Methods An electronic search of papers on MEDLINE/PubMed, ScienceDirect, and EBSCOhost was performed. Only in vitro studies were included. Non-English studies, case reports, clinical trials, and review articles were excluded. A meta-analysis of the reviewed studies was conducted to quantify differences in the microhardness of the Z250 microhybrid resin composite using the Comprehensive Meta-Analysis software. Results Only 13 studies met the inclusion criteria for this systematic review. The meta-analysis showed that there were significant differences between the non-preheated and preheated modes for both the top and bottom surfaces of the specimens (p < 0.05). The microhardness of the Z250 resin composite on the top surface in the preheated mode (78.1 ± 2.9) was higher than in the non-preheated mode (67.4 ± 4.0; p < 0.001). Moreover, the microhardness of the Z250 resin composite on the bottom surface in the preheated mode (71.8 ± 3.8) was higher than in the non-preheated mode (57.5 ± 5.7, p < 0.001). Conclusions Although the results reported in the reviewed studies showed great variability, sufficient scientific evidence was found to support the hypothesis that preheating can improve the hardness of resin composites.