RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Engineering of AlON interlayer in Al2O3/AlON/In0.53Ga0.47As gate stacks by thermal atomic layer deposition

        이우철,조철진,박석인,전동환,송진동,황철성,김성근 한국물리학회 2018 Current Applied Physics Vol.18 No.8

        The presence of an AlN interfacial layer in high-k/In0.53Ga0.47As gate stacks improves the interfacial properties and enhances the electrical performance of devices. However, pure AlN is rarely grown by atomic layer deposition (ALD) because of the low reactivity of NH3 toward the common Al-precursor and the predisposition to oxidation of the grown AlN layer. Although a plasma-enhanced ALD technique significantly suppresses the oxygen content in the grown AlN layer, the deterioration of the interface properties by plasma-damage is a critical issue. In this work, an AlON interlayer was engineered by optimizing the NH3 feeding time in thermal ALD to improve the interface quality in Al2O3/AlON/In0.53Ga0.47As capacitors. It was determined that a mere increase in the NH3 feeding time during the ALD of the AlON film resulted in a higher nitrogen incorporation into the AlON interlayer, leading to a reduction in the interface trap density. Furthermore, the out-diffusion of elements from the In0.53Ga0.47As layer was effectively suppressed by increasing the NH3 feeding time. This work demonstrates that simple process optimization can improve the interface quality in high-k/In0.53Ga0.47As gate stacks without the use of any plasma-activated nitrogen source.

      • KCI등재

        2중 컨버터 구조를 갖는 계통 연계형 UPS의 DC 충전 알고리듬에 관한 연구

        이우철,유동상 한국조명.전기설비학회 2005 조명·전기설비학회논문지 Vol.19 No.3

        This paper presents a threephase Line-Interactive uninterruptible power supply(UPS) system with dual converter structure. The threephase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator, which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low total harmonic distortion(THD). This paper presents in the series and parallel active compensator charging method depending on the amplitude of the source voltage. The conventional Line-Interactive UPS system is responsible for the DC charging and output voltage regulation at the same time, but UPS system with dual converter structure, a series active compensator can also charge the DC link. Therefore, the charging algorithm using the series and parallel compensator needs to be researched. Therefore, by making the DC link voltage stable, it can contribute the stability of series and parallel compensator. The simulation and experimental result are depicted in this paper to show the effect of the proposed algorithm. 본 논문에서는 2개의 컨버터 구조를 갖는 삼상 계통 연계형 UPS에 대하여 연구한다. 삼상 UPS 시스템은 2개의 능동 전력 보상기 구조로 이루어져 있다. 하나는 직렬형으로 .전원전압과 동상의 전압원으로 동작하여 전원전압의 변동, 왜곡시에도 정현파 전원전류와 고역률을 갖도록 동작한다. 병렬형은 전원전압과 위상을 맞춘 종전의 정현파 전압원으로 동작하여 부하에 안정되고 낮은 THD를 갖는 정현파 전압을 공급한다. 본 논문에서는 직렬형, 병렬형 능동보상기에서 전원전압의 크기에 따라 충전 방법에 대하여 제시한다. 종전의 계통 연계형 UPS는 DC 충전과 출력전압을 동시에 제어하였는데, 2개의 컨버터 구조를 갖는 UPS 시스템에서는 직렬형 보상기도 DC 충전을 할 수 있어 직렬형과 병렬형을 사용한 충전 알고리듬을 연구할 필요가 있다. 따라서 DC link 단의 전압을 안정시켜 본래의 직렬형, 병렬형 구조의 보상기의 안정성 향상에 기여할 수가 있다. 제안된 방법의 타당성은 시뮬레이션과 실험 결과를 통하여 입증된다.

      • KCI등재

        A Study on DC Changing Algorithm of the Line-Interactive UPS with Dual Converter Structure

        이우철,유동상,Lee, Woo-Cheol,Yoo, Dong-Sang The Korean Institute of IIIuminating and Electrica 2005 조명·전기설비학회논문지 Vol.19 No.3

        본 논문에서는 2개의 컨버터 구조를 갖는 삼상 계통 연계형 UPS에 대하여 연구한다. 삼상UPS시스템은 2개의 능동 전력 보상기 구조로 이루어져 있다. 하나는 직렬형으로 .전원전압과 동상의 전압원으로 동작하여 전원전압의 변동, 왜곡시에도 정현파 전원전류와 고역률을 갖도록 동작한다. 병렬형은 전원전압과 위상을 맞춘 종전의 정현파 전압원으로 동작하여 부하에 안정되고 낮은 THD를 갖는 정현파 전압을 공급한다. 본 논문에서는 직렬형, 병렬형 능동보상기에서 전원전압의 크기에 따라 충전 방법에 대하여 제시한다. 종전의 계통 연계형 UPS는 DC 충전과 출력전압을 동시에 제어하였는데, 2개의 컨버터 구조를 갖는 UPS 시스템에서는 직렬형 보상기도 DC 충전을 할 수 있어 직렬형과 병렬형을 사용한 충전 알고리듬을 연구할 필요가 있다. 따라서 DC link단의 전압을 안정시켜 본래의 직렬형, 병렬형 구조의 보상기의 안정성 향상에 기여할 수가 있다. 제안된 방법의 타당성은 시뮬레이션과 실험 결과를 통하여 입증된다. This paper presents a three phase Line-Interactive uninterruptible power supply(UPS) system with dual converter structure. The three phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator, which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low total harmonic distortion(THD). This paper presents in the series and parallel active compensator charging method depending on the amplitude of the source voltage. The conventional Line-Interactive UPS system is responsible for the DC charging and output voltage regulation at the same time, but UPS system with dual converter structure, a series active compensator can also charge the DC link. Therefore the charging algorithm using the series and parallel compensator needs to be researched. Therefore, by making the DC link voltage stable it can contribute the stability of series and parallel compensator. The simulation and experimental result are depicted in this paper to show the effect of the proposed algorithm.

      • KCI등재후보

        통합 전력품질 제어기의 과전류 보호방법에 관한 연구

        이우철,김한정 한국조명전기설비학회 2002 조명·전기설비학회논문지 Vol.16 No.5

        본 논문에서는 직렬형, 병렬형 능동전력필터로 구성되어 있는 통합전력품질 제어기(UPQC)의 과전류에 대한 보호기법이 제시되며, 해석된다. 제안된 과전류 보호기법은 직렬형 능동전력필터에 과전류의 기본파 성분에 대해서고 임피던스를 갖는 기능을 부여함으로써 구현하였으며, 세 가지 방법을 제시하였다. 첫 번째 방법은 p-q이론을 이용하여 기본파 전원전류를 검출하여 보호하는 방법, 두 번째 방법은 동기 좌표계에서 부하전류의 기본파 성분을 검출하여 보호하는 방법, 세 번째 방법은 입력전압을 검출하여 보호하는 방법이다. 전원계통에서 과전류가 흘렀을 경우 제안된 방법들은 UPQC에 부가적인 회로 없이 보호해 줄 수 있다. 제안된 방법의 타당성은 시뮬레이션 결과를 통하여 입증된다. A protection scheme for Unified Power Quality Conditioner (UPQC) is presented and analyzed in this paper. The proposed UPQC has the series active power filter operated as a high impedance k($\Omega$) to the fundamentals when the over current occurs in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory,[1] the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame(SRF) and the third is the method by detecting the input voltage. When the over current occurs in the power distribution system, the proposed scheme protects the UPQC without additional protection circuits. The validity of proposed protection scheme is investigated through simulation results.

      • 러시아 구성주의의 그래픽 디자인 스타일에 관한 연구

        이우철,홍성일 경운대학교 산업기술연구소 2002 産業技術硏究論文誌 Vol.4 No.2

        Different from other design movement, Russian Constructivism was born while it was deeply rooted in the political change. Designers have pursued such a perspective of social role to build a new social environment as well. With creative expressions and skills of various tests, Russian Constructivism has established an early method of expression in the modern graphic design. Although it has not further developed in Russia due to a political situation and social environment, the design concept and formative world implanted in other countries laid the foundations of the modern graphic design, which would form a standard of graphic design in the early 20th century.

      • KCI등재

        RL 부하 연동 단상 태양광 발전 시스템의 부하 전류 센서리스 무효 전류 보상기법

        이우철,송민근 대한전기학회 2023 전기학회논문지 Vol.72 No.1

        The PV (photovoltaic) system can be used with RL loads on the grid side. However, when RL Load is connected, the phase of the grid current and voltage will not match due to the reactive current component. The reactive current generated at this time can be compensated by the inverter. In the case of such a single-phase PV system, a total of two current sensors are used to detect the inverter output current and the RL load current. This paper proposes a compensation technique using one current sensor without using two current sensors in a single-phase photovoltaic power generation system connected with an RL load.

      • KCI등재

        브랜드 인지도에 따른 라이브 커머스의 구매설득커뮤니케이션 전략 내용분석

        이우철,나정희 한국광고PR실학회 2022 광고PR실학연구 Vol.15 No.1

        본 연구는 최근 마케팅커뮤니케이션 플랫폼으로서 주목받고 있는 라이브 커머스의 내용분석을 통해 이러한 도구가 어떠한 방식으로 소비자들을 설득하고 있는지를 파악해보자 하였다. 이를 위해 우선 라이브 커머스가 어떠한 구매설득커뮤니케이션 전략들을 주로 많이 사용하고 있으며, 이러한 전략이 브랜드의 인지도에 따라 어떻게 다른지 살펴보았다. 또한 라이브 커머스의 가장 큰 특징이자 장점인 쌍방커뮤니케이션의 활용 빈도를 살펴보고 이를 브랜드 인지도에 따라 어떤 차이를 보이고 이러한 쌍방커뮤니케이션은 어떤 구매설득커뮤니케이션 전략을 사용하는지 살펴보았다. 끝으로 라이브 커머스의 진행상 위치에 따른 구매설득커뮤니케이션 전략 유형들의 빈도 및 쌍방커뮤니케이션 활용 빈도를 살펴보았다. 결과는 다음과 같다. 첫째, 가장 많이 사용된 전략 유형은 제품 매력성이었고 그 뒤로 상호 호혜성, 일시적 감정공동체, 가격 매력성으로 나타났다. 둘째, 고인지도 브랜드의 경우 상호 호혜성, 일시적 감정 공동체, 가격 매력성, 희소성 전략을, 저인지도 브랜드의 경우는 제품매력성, 사회적 증거, 권위호소, 구매안정성보장 전략을 더 많이 사용하는 것으로 나타났다. 셋째, 라이브 커머스에서 쌍방향커뮤니케이션의 상호작용성을 활용하는 빈도가 아직은 많이 부족하며 활용하고 있는 전략 유형(사회적 증거, 상호 호혜성)도 매우 제한적이었다. 넷째, 라이브 커머스의 진행상 위치에 따라 사용되는 구매설득커뮤니케이션 전략과 커뮤니케이션 유형이 다름을 확인할 수 있었다. 전반부에는 제품과 직접적 관련이 적은 전략들(일시적 감정공동체, 사회적 증거, 권위호소, 긍정적 소비가치)이 주로 사용되고 후반부에는 제품과 직접적 관련성이 높은 설득 전략들(제품 매력성, 상호 호혜성, 가격 매력성, 희소성, 구매안정성 보장)을 사용하는 것으로 나타났다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼