슬래브-기둥 접합부의 이력거동에 대한 기둥 형상비의 영향
조인중(Cho In-Jung),최명신(Choi Myung-Shin),안종문(Ahn Jong-Moon),신성우(Shin Sung-Woo) 대한건축학회 2007 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.27 No.1
In this investigation, results of laboratory tests on four reinforce concrete flat plate interior connections with elongated rectangular column support which has been used widely in tall residential buildings are presented. The purpose of this study is to evaluate an effect of column aspect ratio(βc=c₁/c₂=side length ratio of column section in the direction of lateral loading (c₁) to the direction of perpendicular to c₁) on the hysteretic behavior under earthquake type loading. The aspect ratio of column section was taken as 0.5~3(c₁/c₂=1/2, 1/1, 2/1, 3/1) and the column perimeter was held constant at 1200㎜ in order to achieve nominal vertical shear strength(Vc) uniformly. Other design parameters such as flexural reinforcement ratio of slab and concrete strength was kept constant as p=1.0% and fok=40㎫, respectively. Gravity shear load(Vg) was applied by 30 percent of nominal vertical shear strength(0.3Vo) of the specimen. Experimental observations on punching failure pattern, peak lateral-load and story drift ratio at punching failure, and stiffness degradation and energy dissipation in the hysteresis loop were achieved and discussed in accordance with different column aspect ratio. Eccentric shear stress model of ACI 318-05 was evaluated with experimental results. A fraction of transferring moment by shear and flexure in the design code was analyzed based on the test results.
반복 횡하중을 받는 장방형 기둥-슬래브 접합부의 이력거동에 대한 철근비의 영향
문미진(Mun Mi-Jin),조인중(Cho In-Jung),최명신(Choi Myung-Shin),신성우(Shin Sung-Woo) 대한건축학회 2008 大韓建築學會論文集 : 構造系 Vol.24 No.11
In this investigation, results of laboratory tests on six reinforced concrete flat plate interior connections with elongated rectangular column support which has been used widely in tall residential buildings are presented. The purpose of this study is to evaluate an effect of slab reinforcement ratio and column aspect ratio(βc=c₁/c₂) on the hysteretic behavior under earthquake type loading. The aspect ratio of column section was taken as 0.33~3(c₁/c₂=1/3, 1/1, 3/1) and the flexural reinforcement ratio was taken as 0.01 and 0.015(ρ=1.0%, 1.5%). Other design parameters such as concrete strength were kept constant as fck=40㎫, respectively. Gravity shear load(Vg) was applied by 30 percents of nominal vertical shear strength(0.3V?) of the specimen. Experimental observations on punching failure pattern, peak lateral-load and story drift ratio at punching failure, stiffness degradation, displacement ductility index and energy dissipation in the hysteresis loop were achieved and discussed in accordance with different reinforcement and column aspect ratio. Eccentric shear stress model of ACI 318-05 was evaluated with experimental results.
반복 횡하중을 받는 장방형 기둥-슬래브의 중력전단력비에 대한 실험적 연구
조인중 ( Cho In-jung ),최명신 ( Choi Myung-shin ),신성우 ( Shin Sung-woo ) 한국구조물진단유지관리공학회 2008 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.12 No.2
In this investigation, results of laboratory tests on six reinforced concrete flat plate interior connections with elongated rectangular column support which has been used widely in tall residential buildings are presented. The purpose of this study is to evaluate an effect of slab reinforcement ratio and column aspect ratio(β<sub>c</sub>=c1/c2) on the hysteretic behavior under earthquake type loading. The gravity shear load(V<sub>g</sub>) was applied by 30 and 50 percent of nominal vertical shear strength(0.3, 0.5V0) and the aspect ratio of column section was taken as 0.33~3(c1/c2=1/3, 1/1, 3/1). Other design parameters such as concrete strength were kept constant as f<sub>ck</sub>=40MPa, respectively, the flexural reinforcement ratio was taken as 0.0(p=1.0%). Experimental observations on punching failure pattern, peak lateral-load and story drift ratio at punching failure, stiffness degradation, displacement ductility index and energy dissipation in the hysteresis loop were achieved and discussed in accordance with different reinforcement and column aspect ratio. Eccentric shear stress model of ACI 318-08 was evaluated with experimental results.