철근콘크리트 구조물에서 철근부식 모니터링을 위한 부식센서 개발에 관한 연구
조성형(Joh, Sung-Hyung),이현석(Lee, Hyun-Seok),이한승(Lee, Han-Seung) 한국구조물진단유지관리학회 2010 한국구조물진단학회 학술발표회논문집 Vol.2010 No.2
Corrosion sensors were devised to develop a system whereby the depth of chloride permeation from concrete surfaces can be monitored in cover concrete of reinforced concrete structures. For making sensor which is similar to rebar author uses Screen printer machines, Ag paste and Fe powder. Appropriate portion of Ag and Fe is over 1:2. The resistance of sensors increased as the degree of corrosion increased. And according to cover depth author suggests sensor system which has a demanded cover depth. It was therefore confirmed that the corrosion sensor can monitor chloride permeation by change of resistance.
콘크리트내 염분침투 모니터링을 위한 부식 센서 개발에 관한 기초적 연구
조성형 ( Sung Hyung Joh ),이현석 ( Hyun Seok Lee ),이한승 ( Han Seung Lee ) 한국건축시공학회 2010 한국건축시공학회 학술발표대회 논문집 Vol.10 No.1
Corrosion sensors were devised to develop a system whereby the depth of chloride permeation from concrete surfaces can be monitored in cover concrete of reinforced concrete structures. For making sensor which is similar to rebar author uses Screen printer machines, Ag paste and Fe powder. Appropriate portion of Ag and Fe is over 1:2. The resistance of sensors increased as the degree of corrosion increased. And according to cover depth author suggests sensor system which has a demanded cover depth. It was therefore confirmed that the corrosion sensor can monitor chloride permeation by change of resistance.