http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
N₂와 CF₄ 혼합물을 작동유체로 하는 극저온 열사이펀에 대한 실험적 연구
김영권(Youngkwon Kim),이지성(Jisung Lee),정상권(Sangkwon Jeong),한영희(Younghee Han),정세용(Seyong Jung),박병준(Byungjun Park) 대한설비공학회 2009 설비공학 논문집 Vol.21 No.9
A thermosiphon is utilized as a thermal shunt to reduce the cool-down time of a cryogenic system cooled by a two stage cryocooler. The cool-down time reduction by the thermosiphon is determined by the type of working fluid which is directly related to the operating temperature range of the thermosiphon. A mixed working fluid has a potential to widen the operation temperature range of the thermosipohon. In this study, the thermosiphon using N₂ and CF₄ mixture as the working fluid is fabricated and tested to verify its transient heat transfer performance. The thermosiphon with the mixed working fluid has no noticeable reduction of cool-down time compared with that of the thermosiphon with pure working fluid in this experiment. However, it seems that the thermosiphon with mixed working fluid may have an advantage according to the cooling capacity of a cryocooler, the cooling target temperature and the size of a cooling object.