http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
임플란트 고정체의 platform의 크기에 따른 유한요소법적 응력분석
정경민,정재헌,정승미,Chung Kyung-Min,Chung Chae-Heon,Jeong Seung-Mi 대한치과보철학회 2003 대한치과보철학회지 Vol.41 No.5
Statement of Problem : With increasing demand of the implant-supported prosthesis, it is advantageous to use the different platform width of the fixture according to bone quantity and quality of the patients. Purpose : The purpose of this study was to assess the loading distributing characteristics of two implant designs according to each platform width of fixture, under vertical and inclined loading using finite element analysis. Material and method : The two kinds of finite element models were designed according to each platform width of future (4.1mm restorative component x 11.5mm length, 5.0mm wide-diameter restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction, 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction and 200N at the buccal cusp in a 300 transverse direction individually Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. Results : The stresses were concentrated mainly at the cortex in both vertical and oblique load ing but the stresses in the cancellous bone were low in both vertical and oblique loading. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading. Increasing the platform width of the implant fixture decreased the stress in the supporting bone, future and abutment screw. Increased the platform width of fixture decreased the stress in the crown and platform. Conclusion : Conclusively, this investigation provides evidence that the platform width of the implant fixture directly affects periimplant stress. By increasing the platform width of the implant fixture, it showed tendency to decreased the supporting bone, future and screw. But, further clinical studies are necessary to determine the ideal protocol for the successful placement of wide platform implants.
조재완(Jai-Wan Cho),정경민(Kyung-Min Jeong) 대한전기학회 2012 전기학회논문지 Vol.61 No.8
In this paper, the gamma ray irradiation test results of the CCD cameras are described. From the low dose-rate (2.11 Gy/h) to the high dose-rate (150 Gy/h) level, which is the same level when the hydrogen explosion was occurred in the 1~3 reactor unit of the Fukushima nuclear power plant, the monitoring performance of the cameras owing to the speckles are evaluated. The numbers of speckles, generated by gamma ray irradiation, in the image of cameras are calculated by image processing technique. And the legibility of the sensor indicator (dosimeter) owing to the numbers of the speckles is presented.
조재완 ( Jai-wan Cho ),정경민 ( Kyung-min Jeong ) 한국정보처리학회 2013 한국정보처리학회 학술대회논문집 Vol.20 No.1
원자로 건물 내부에는 원자로의 안전운전을 위한 다수의 계통, 구조물 및 기기들이 위치하고 있다. 원자로의 안전과 직결되는 안전계통 변수 (수위, 압력) 들은 경우에 따라서는 현장확인이 요구된다. 원자로 가동 중에 운전원에 의한 안전계통변수의 현장확인이 용이하도록 원자로 건물 내부의 출입구 (2 중문) 부근에 수위계, 압력계 등의 현장계기가 위치하고 있다. 본 논문에서는 일본의 ㈜ 동경전력이 공개한 후쿠시마 제 1 원자력발전소 1 호기 원자로건물의 IC (비상용 복수기, isolation condenser) 조사영상에 나타나는 현장계기의 영상인식에 대해 기술한다. 조사 영상의 분석에 의하면 현장계기들은 기계식의 아날로그 타입이다. 아날로그 타입의 기하구조를 이용하여 계기판 눈금을 인식하고, 계기판 바늘의 기울기 계산을 통해 계기판을 영상 판독할 수 있었다. 이러한 계기판의 영상판독은 후쿠시마 원전 사고와 같이, 고방사선 피폭 우려로 인해 사람대신에 로봇이 원자로 건물내부에 진입하여 주요 계통, 구조물 및 기기의 현장계기를 판독한다고 가정하면, 유용한 기능이다.