http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
최두성(Choi Doo-Sung),전흥찬(Chun Hung-Chan),조균형(Cho Kyun-Hyong) 한국건축친환경설비학회 2010 한국건축친환경설비학회 논문집 Vol.4 No.2
In this research, the wall construction method influences the partially exposed situation in the one sided corridor type that is a form of the representing tenement house within the nation. A computer simulation was performed, with the purpose to analyse, suggest problems and development plans of safety in cases of fire. As a result of the analysis, all analyzing cases which the fire scenarios were applied in the middle and end complexes, showed that minimum evacuation time were within 195 seconds and 348 seconds, and if a part of the on sided corridor was opened with fire the safety of the residents were improved and the residential environment too were suggested possible for development.
차열도료 적용을 통한 국내 건축물의 에너지 성능 변화에 관한 연구
최두성(Choi Doo-Sung),전흥찬(Chun Hung-Chan),조균형(Cho Kyun-Hyong) 한국태양에너지학회 2011 한국태양에너지학회 논문집 Vol.31 No.5
In this study it is quantitatively analyzed for thermal Characteristics of isolation-heat paint which has been supplied to a domestic market through experiments and simulations. In the case of experiment using the container box it shows 8% decrease on cooling energy consumption in a summer season but shows increase on heating energy consumption. As a result the analysis has found increase of energy consumption. As a result of holding simulations with meteorological data of domestic major cities it shows an increase of energy consumption in domestic condition and it is hard to expect an energy saving from the isolation-heat paint unless greater air-conditioning load.
공동주택 평면유형조합에 따른 시공단계 CO₂ 배출원단위 특징 분석
최두성(Doo-Sung Choi),전흥찬(Hung-Chan Chun),조균형(Kyun-Hyong Cho) 한국생활환경학회 2011 한국생활환경학회지 Vol.18 No.3
This research quantified (/m²) the supplied materials at the construction stage of apartments, the main architecture form domestically, and presented the average CO₂ emission by analyzing 50 apartment complexes. The results are as follows. CO₂ emission of each type of constructions by supplied materials is architecture (78.8%), machine (8.8%), electricity (5.3%), civil engineering (3.4%), landscaping (3.4%), and communication (1.0%). The building construction charged about 79%. Average CO₂ emission of total 50 apartment complexes according to supplied material expense appeared to be 950 kg-CO₂/m², and when core-type pillar was included CO₂ emission largely increased.
최두성(Choi, Doo-Sung),전흥찬(Chun, Hung-Chan),조균형(Cho, Kyun-Hyung) 대한건축학회 2013 대한건축학회논문집 Vol.29 No.1
This study evaluated the environmental effect indwelling in an apartment by executing LCA for building materials inputted into a domestic apartment, and selected major materials by analyzing the inputted material change rate in various apartments. This study presented the methodology that can have a similar result to the environmental effect assessment of all materials by using only the finally selected major materials. For this study, a total of 274 apartment houses in 27 apartment house complexes were analyzed to select 27 kinds of major materials as its result. The average environmental effect in 274 apartment houses was analyzed to be 3.58E-02pe yr per unit area(/㎡), and as a result of environmental effect assessment using 27 kinds of major materials, the average error rate from the actual result was 4.9%.