http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
PM_(10) 개인노출과 공중이용시설내 농도에 관한 연구
김만구,정영림,임양석 江原大學校 附設 環境硏究所 1998 環境硏究 Vol.15 No.-
PM_(10) concentrations were measured measured in underfround stores located in 4 major cities, Chuchon, Wonju, Donghae and Sockcho, in Kangwon-Do using scattering light integrated type digital dust indicator. Personal exposure to PM_(10) for two women(housekeeper and granduate stuent) and a man(undergraduate student were measured also. The dimensional conversion factors for mass concentrations(K) showed some difference among underground stores which were 2.0,2.7,3.4,2.6㎍/㎥·CPM in chunchon, Wonju, Donghae and Sockcho, respectively. Average PM(10) concentrations at underground stores were 178㎍/㎥ in Chunchon, 141㎍/㎥ in Wonju, 125㎍/㎥ in Donghe and 59㎍/㎥ in Sockcho. The portion of PM_(10) in total suspended particles was about 50~60 % as weight. The exposure of graduate student, housekeeer and undergraduate to PM_(10) during 12 hours were 1004.3(㎍/㎥)·hr, 907.0(㎍/㎥)·hr and 691.2(㎍/㎥)·hr, respectively. Personal exposure to PM_(10) showed very different according to their activity parttern and they had more than 90% of their PM_(10) exposure at indoor envirnment.