http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Size와 Taper가 ProFile과 Hyflex CM Ni-Ti 파일의 기계적 물성 변화에 미치는 효과
이형우(Hyungwoo Lee),이창하(Chang-ha Lee),이인복(In-bog Lee) 대한치과재료학회 2022 대한치과재료학회지 Vol.49 No.1
The purpose of this study was to investigate the effect of size and taper on the mechanical properties of two Ni-Ti files. A controlled memory Ni-Ti file, Hyflex CM (Coltène-Whaledent, Altstätten, Switzerland) and a conventional Ni-Ti file, ProFile (Dentsply Maillefer, Ballaigues, Switzerland) were used. The size and taper (sizer/taper values) were 20/.04, 25/.04, 25/.06 and 30/.04. The U-Mechanics Analyser (IB Systems, Seoul, Korea) was used to measure the bending, torsional, and fatigue fracture resistance of the files (n=5). ProFile showed elastic deformation, but Hyflex CM showed higher hysteresis with plastic deformation in bending resistance test. The bending and torsional resistance of ProFile increased with increasing size and taper, though the #25 and #30 files of Hyflex CM did not resulted in any change. Hyflex CM showed greater fatigue fracture resistance than ProFile in all sizes and tapers. Without considering root canal excavation efficiency, it is considered that Hyflex CM has better root canal trackability and fewer fatigue fractures than ProFile.
이창하,Lee, Chang-Ha 한국정밀공학회 1987 한국정밀공학회지 Vol.4 No.4
어떤 산업이든 기계공업이 관여되지 않는 분야가 없듯이 공작기게가 관여되지 않는 기계공업은 생각할 수 없다. 이와같이 공작기계는 <기계를 만드는 기계> 라는 점에서 모든 산업분야의 근간을 형성하고 있으므로 공작기계의 품질과 성능은 곧 한나라의 기술수준을 가늠하는 척도로서 대표된다고 하여도 과언은 아 니다. 오늘날 선진국들은 수요자가 요구하는 다양한 초정밀공작기계까지도 만들고 있다. 크게는 우주개발에 서 항공기, 선박 및 자동차생산을 위시하여 건설장비, 전자 및 광학, 정밀화학, 각종 시험기기 등 공작기계의 손이 미치지 않은 곳이 없다. 이렇게 공작기계는 전산업에 걸쳐 크게 영향을 주고 있으며, 특히 최근의 산업 화 추세가 점차 자동화, 무인화, 초정밀첨단산업으로 비약함에 따라 공작기계의 역할은 더욱더 중요시되고 있 다. 우리나라 공작기계공업은 1960 년대의 이전 극히 영세한 중소기업중심의 보수공작기계부품 생산형태에서 1960 년대 후반부터 일부 범용기종의 생산이 시작되었으나 보다 본격화한 것은 1973 년 정부의 중화학공업육성 시책에 따라 대기업의 대거 참여로 공작기계제조업은 시설, 자산, 경영면에서 대형화 하였고, 동시에 선진국의 최신기술과 시설을 적기에 도입하므로써 품질향상, 신제품개발, 수출참여 등 공작기계공업 발전에 일대 전기를 마련하였다. 특히 '85 년에 들어서면서부터 3 저의 여파로 국내 자동차산업의 호황, 전자, 기계 및 관련수요 산업의 설비투자와 시설개체에 힘입어 공작기계생산도 활발하기 시작하여 그 어느때보다 생산기반혁신을 위한 구조적 대응책이 절실해지고 있다. 따라서 공작기계공업의 당면과제는 지속적인 기술개발과 품질향상으로 국산 화율을 제고시켜야 함은 물론, 이를 양산화하여 명실공히 선도산업으로서의 위치를 굳히고, 적어도 기계류의 수입국에서 기계류의 수출국으로 기치를 든 탈바꿈을 할때 비로소 불균형이 없는 흑자시대는 도래할 것이다.
이창하(Chang-Ha Lee),임범순(Bum-Soon Lim),이인복(In-Bog Lee) 대한치과재료학회 2016 대한치과재료학회지 Vol.43 No.4
The purpose of this study was to evaluate the color and translucency of multi-shade layered composites. To simulate a class IV direct composite restoration, 4 mm-thick disc-shaped specimens (15 mm in diameter) were prepared. Z250 (A2) or Z350XT (A2 enamel (E), body (B), and dentin (D)) were bulk-filled. Both Z350XT/A2E and Z350XT/A3D were bi-layered, in which the thickness of Z350XT/A2E was increased from 1.0 mm to 3.0 mm with an increment of 1.0 mm while the thickness of Z350XT/A3D was decreased. Total thicknesses of the sandwiched specimens were maintained at 4 mm. The CIELAB parameters (L*, a*, and b*) of specimens were measured using a spectrophotometer to calculate the color difference (ΔE) without background, and to calculate translucency parameter (TP) on a white or black background. One-way ANOVA and post-hoc Tukey’s test were employed for statistical analysis. ΔE between Z250 (A2) and three different shades of Z350XT (A2E, A2B, and A2D) were greater than 3.3, that was an unacceptable level. ΔE between a bulk-filled specimen with Z350XT/A2B and layered specimen with the Z350XT/A2E and Z350XT/A3D was the lowest in a specimen of A2E 2 mm + A3D 2 mm (p<0.05). Statistically significant difference was found between the TP values of bulk-filled specimens (p<0.05). The TP values of layered specimens increased with increasing the thickness of enamel shade (p<0.05). Within the limitation of this in vitro study, the combined layering with 2 mm-thick A2E and 2 mm-thick A3D is recommended for the class IV direct composite restoration with a Z350XT/A2 shade.
근단 협착부 직경, 세척액 주입속도, 주사침 말단의 형상이 치근단에 작용하는 압력에 미치는 영향
이창하(Chang-Ha Lee),조설아(Seol-Ah Jo),임범순(Bum-Soon Lim),이인복(In-Bog Lee) 대한치과재료학회 2019 대한치과재료학회지 Vol.46 No.2
The purpose of this study was to evaluate the effects of apical constriction (AC) diameter, irrigant flow rate, and needle tip design on apical pressure (AP) during the root canal irrigation. Five extracted human mandibular premolars were instrumented up to #35 (0.06 taper) using nickel-titanium rotary instruments. AC was determined at 1 mm from the apical foramen. Three needles with different tip designs (notched, side-vented, and flat) were placed 3 mm from AC. APs were measured with varying flow rates of 0.05, 0.1, 0.2, and 0.3 mL/s. The AC diameter of the teeth was enlarged to #40 and #45 (0.06 taper) successively, and the aforementioned measurement procedure was repeated (n=5). When the other conditions were controlled, AP increased with decreasing AC diameter or increasing irrigant flow rate, and the AP of flat needle was the highest, followed by notched, and side-vented needle (p<0.05). The APs with 0.05 mL/s flow rate were lower than central venous pressure (5.88 mmHg) for all conditions. Under the conditions of the present study, flat needle is not recommended in narrow AC (0.35 mm), as the value of the AP with a flow rate of 0.05 mL/s is similar to the central venous pressure. However, in AC diameter of >0.35 mm, open-end (notched or flat) needles can be used to improve irrigant replacement in the apical portion using a flow rate of 0.05 mL/s.