        자체 제작한 자기공명영상 고주파 차폐체의 유용성 평가

        이진회,이보우 한국융합학회 2020 한국융합학회논문지 Vol.11 No.11

        This paper proposes a better shielding method to over sampling technique. The new method uses aluminum foil for RF shielding. As a result of the phantom test, when the over-sampling technique was applied, the aliasing artifact was reduced by about 94% compared to before the application, and the case where the aluminum shielding band was applied was also reduced by about 92% compared to before application. In addition, the scan time also increased by more than 3 times in the case of the over-sampling technique, while it was found that there was no change from before the application of the aluminum shielding band Therefore, it was confirmed that the shielding band using aluminum foil can effectively remove aliasing artifacts without increasing the scan time. 자기공명영상 고주파를 차단할 수 있는 금속물질 중 자장에 영향을 받지 않으며 가격이 저렴하고 주위에서 쉽게 구할 수 있는 알루미늄 호일을 이용하여 차폐체를 제작하였다. Phantom 실험 결과 over-sampling 기법을 적용한 경우 적용 전보다 aliasing artifact가 약 94% 감소하였고, 알루미늄 차폐체를 적용한 경우도 적용 전 보다 약 92% 감소하였다. 그리고 scan time도 over-sampling 기법의 경우 적용 전보다 약 3배이상 증가한 반면, 알루미늄 차폐체의 경우는 적용 전과 변화가 없는 것으로 나타났다. 따라서 알루미늄 호일을 이용한 차폐체도 기존의 흡수재 및 차폐체들과 마찬가지로 scan time의 증가 없이 aliasing artifact를 효율적으로 제거할 수 있는 것을 확인하였다.

      • KCI등재

        고등학생을 위한 철학적 글쓰기 지도 방안

        이진회(Lee, Jin-Hoe) 새한철학회 2018 哲學論叢 Vol.93 No.3

        학생부종합전형의 영향으로 고등학교에서 글쓰기는 점점 더 중요해지고 있다. 이 때 필요한 것은 철학적 글쓰기이다. 그럼에도 불구하고 여전히 고등학교에서 글쓰기는 국어 교사의 전유물로 여겨진다. 그 원인 중 하나는 고등학교에 재직하고 있는 철학 교사가 많지 않기 때문이며, 다른 하나는 철학적 글쓰기에서 ‘쓰기’만 강조되기 때문이다. 고등학교의 글쓰기 영역 중 ‘논술’, ‘토론’, ‘소논문’의 기본은 비판적 사고 능력이며, 이를 바탕으로 한 논증적 글쓰기이다. 그러나 대부분의 교사들과 학생들에게 그 토대가 되어야 하는 철학과 논리학은 여전히 어렵고 낯설다. 이 글은 고등학생들에게 필요한 철학적 글쓰기 분야 중 ‘논술’, ‘토론’, ‘소논문’ 영역에 도움이 될 수 있는 비판적 사고 영역과 이를 활용한 글쓰기 방안을 제시하고 있다. 분석적 글쓰기, 논증적 글쓰기, 반성적 글쓰기라는 영역별 특성을 고려한 방법을 통해 각 영역에 비판적 사고를 활용하고, 철학적 글쓰기의 효용성을 인식할 수 있을 것이다. Writing is becoming more important in high school because of the influence of the Comprehensive School Report Policy. What is needed at this time is philosophical writing. Nonetheless, writing in high school is still regarded as the exclusive right of Korean language teachers. One reason is that there are not many philosophy teachers in high school, and the other is that only ‘writing’ is emphasized in philosophical writing. Among the writing sections of high school, the basis of ‘Essay writing’, ‘Debate’ and ‘R&E’ are critical thinking ability and argumentative writing. However, the philosophy and logic that should be the foundation for most teachers and students is still difficult and unfamiliar. The article presents and utilizes critical thinking areas that can be helpful in the areas of ‘Essay writing’, ‘Debate’ and ‘R&E’ among the philosophical writing areas required by high school students. Critical thinking will be used in each area and the effectiveness of philosophical writing will be recognized through methods that take into account the domain characteristics of analytical writing, argumentative writing, reflective writing.

      • CT 검사 시 산란선 분포에 관한 연구 The Study of Distribution Scatter Ray when Computed Tomography

        김기진,이진회,유세종,김정호,서선열,임재동 대한안전경영과학회 2016 대한안전경영과학회 학술대회논문집 Vol.2016 No.04

        CT scan 시 X-ray tube는 환자를 중심으로 360° 회전을 하기 때문에 산란선은 모 든 방향에서 발생한다. 임상에서 환자의 피폭을 감소시키기 환자의 흉·복부 전면만을 차폐하고 환자 후면이나 측면에서 발생되는 산란선에 대한 차폐는 시행하고 있지 않 다. 두부(Brain) CT 검사 시 흉부 및 복부에 입사되는 산란선을 ion chamber로 측정 하여 그 분포를 확인하고 두부 CT 검사 시 발생되는 산란선의 분포를 통해 기존 차폐 방법의 적정성을 평가 하고자 한다. 연구결과 gantry angle이 클수록, 전면보다 후면에 서 산란선이 많이 발생했다. 두부 CT 검사 시 발생되는 산란선에 의한 피폭을 최소화 하기 위해 가급적 gantry angle을 작게 줄 수 있도록 환자 두부의 위치를 조정하여 검 사를 하거나 납치마를 이용하여 환자의 흉·복부를 차폐할 경우 전면 뿐 아니라 양 측 면과 후면을 납치마를 이용하여 차폐를 해야 할 것이다.

      • CT 검사 시 산란선 분포에 관한 연구

        김기진,이진회,유세종,김정호,서선열,임재동 대한안전경영과학회 2016 대한안전경영과학회 학술대회논문집 Vol.2016 No.04

        CT scan 시 X-ray tube는 환자를 중심으로 360° 회전을 하기 때문에 산란선은 모 든 방향에서 발생한다. 임상에서 환자의 피폭을 감소시키기 환자의 흉·복부 전면만을 차폐하고 환자 후면이나 측면에서 발생되는 산란선에 대한 차폐는 시행하고 있지 않 다. 두부(Brain) CT 검사 시 흉부 및 복부에 입사되는 산란선을 ion chamber로 측정 하여 그 분포를 확인하고 두부 CT 검사 시 발생되는 산란선의 분포를 통해 기존 차폐 방법의 적정성을 평가 하고자 한다. 연구결과 gantry angle이 클수록, 전면보다 후면에 서 산란선이 많이 발생했다. 두부 CT 검사 시 발생되는 산란선에 의한 피폭을 최소화 하기 위해 가급적 gantry angle을 작게 줄 수 있도록 환자 두부의 위치를 조정하여 검 사를 하거나 납치마를 이용하여 환자의 흉·복부를 차폐할 경우 전면 뿐 아니라 양 측 면과 후면을 납치마를 이용하여 차폐를 해야 할 것이다.

      • KCI등재
      • PET-CT에 사용하는 방사성 동위원소 18F를 이용한 납가운의 유용성 평가

        조영학,박명철,송지원,임채영,김기진,유세종,이진회,김정호 대한안전경영과학회 2016 대한안전경영과학회 학술대회논문집 Vol.2016 No.04

        본 연구의 목적은 임상의 핵의학, PET 진단 분야에서 진단 시에 사용되는 방사성 동위원소 중 18F를 이용하여 납가운의 두께 별 에너지스펙트럼을 측정하고 납가운 0.3, 0.5mmPb에 대한 차폐율을 측정하고자 하였다. 에너지 스펙트럼 측정의 경우 자체 제작한 방법으로 측정하였고 차폐율 및 선량 측정의 경우 납가운과 선원의 거리에 대 해 선원과 측정기에 대해 납 가운의 위치를 달리 하여 3가지 조건으로 나누어 각각 20회씩 측정을 하여 평균값을 산출하였다. 에너지 스펙트럼 상에서는 납가운을 위치하 였을 때 본래 방사성 동위원소로부터 방출되는 에너지 외의 에너지 피크영역이 측정 되었고 차폐율 및 선량측정에서는 방사성동위원소 18F은 납가운을 이용하여 차폐를 할 경우 차폐율이 매우 미비하거나 음수의 값이 측정되었다.