http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
실험계획법을 이용한 고층 오피스건물의 연돌효과 대책방안 간 교호작용 분석
서정민(Seo Jung-Min),김재헌(Kim Jae-Hun),김주영(Kim Joo-Young),이중훈(Lee Joong-Hoon),송두삼(Song Doosam) 한국건축친환경설비학회 2012 한국건축친환경설비학회 학술발표대회 논문집 Vol.2012 No.3
With the improved building construction technologies, it can be possible to construct high-rise building, however, the high-rise building accompanies the un-experienced problems such as stack effect in winter in Korea. There are many countermeasures to minimize the stack effect in high-rise building, sometimes the combination of the countermeasures are correct, sometimes are not. But it is difficult to know what the correct combination is. In this study, the interaction between the countermeasures are analyzed by DOE(Design of Measurement) method and Contamw simulation. Targets office building is located in the Seoul, 45-story and reported for the problems caused by stack effect in winter. The meaning of the countermeasures for stack effect in high-rise building and its interaction will be suggested. These results will be used to plan accurate solutions for stack effect in high-rise building.
고층 주거 건물에서 수직적 공기 유동이 건물의 난방 부하에 미치는 영향
김재헌(Kim Jae-Hun),김주영(Kim Joo-Young),서정민(Seo Jung-Min),이중훈(Lee Joong-Hoon),송두삼(Song Doosam) 한국건축친환경설비학회 2012 한국건축친환경설비학회 학술발표대회 논문집 Vol.2012 No.3
In Korea, stack effect is outstanding because of manhattanized residential building and cold weather. Stack effect leads to many habitability-related problems such as noise, strong winds, and poor door opening/closing. Furthermore, indoor environments become more difficult to control by ventilation and air conditioning systems, consequently leading to increased energy consumption. However, the related papers for stack effect are focused on analyzing the reason of stack effect and the effect of countermeasures. In this paper, the effect of the stack effect in high-rise residential building on heating load in winter will be analyzed with building load simulation using airflownetwork model implemented in EnergyPlus. This airflownetwork model was validated with field measurement results. From the simulation results, the heating load is increased about 5% owing to the stack effect in high-rise building in winter.
미지형상 표면의 연삭 작업을 위한 로봇 제어ㆍ계측 시스템 개발
최병오,박근우,이민기,이중훈,Choe, Byeong-O,Park, Geun-U,Lee, Min-Gi,Lee, Jung-Hun 대한기계학회 2000 大韓機械學會論文集A Vol.24 No.4
This paper introduces the control and measurement of a double parallel robot manipulator applied for unknown geometric surface grinding. A measurement system is developed to recognize a grinding path by a vision camera and to observe a grinding load by a current sensor. With the measured fusion information, an intelligent controller identifies the unknown geometric surface and moves the robot along the grinding path with a constant grinding load.
김주영(Kim Joo-Young),김재헌(Kim Jae-Hun),서정민(Seo Jung-Min),이중훈(Lee Joong-Hoon),송두삼(Song Doo-Sam) 한국건축친환경설비학회 2012 한국건축친환경설비학회 학술발표대회 논문집 Vol.2012 No.3
High-rise buildings are being constructed continuously with the concentration of population in downtown areas and the development of the building technology. However, high-rise buildings pose new problems that are not experienced in low-rise buildings, and one representative problem is stack effect. Stack effect is caused by the pressure difference between the inside and outside of a building due to the temperature differences between the two. Stack effect leads to many habitability-related problems such as noise, strong winds, and poor door opening/closing. Furthermore, indoor environments become more difficult to control by ventilation and air conditioning systems, consequently leading to increased energy consumption. Although there are lots of countermeasures to minimize stack effect, there is no significant reduction effect when the countermeasure is wrong applied without understanding the meaning of countermeasure. In this study, the countermeasures which have been studied in previous researches and used today are classified according to the principals. Also, the effect of the countermeasures is analyzed by network simulation method.