이을종(Eul-Jong Lee),송길섭(Kil-Sup Song),오왕규(Wang-Kyu Oh),조진표(Jin-Pyo Cho),김내현(Nae-Hyun Kim) 대한기계학회 2009 대한기계학회 춘추학술대회 Vol.2009 No.11
Effect of air humidity on thermal performance of a enthalpy exchanger was experimentally investigated. The apparatus was specially-made to accurately measure the incoming and outgoing dry and wet bulb air temperatures as well as flow rates. Tests were conducted varying outdoor humidity. It is shown that latent heat exchange effectiveness is solely dependent on absolute humidity. The latent heat exchange effectiveness increases with the increase of absolute humidity. The water vapor permeability of the paper membrane was separately measured, and it is found that the permeability also increases with the increase of absolute humidity. Sensible heat exchange effectiveness is independent of both temperature and humidity.
이을종(Lee, Eul-Jong),김정식(Kim, Jeong-Sig),김내현(Kim, Nae-Hyun) 한국산학기술학회 2012 한국산학기술학회논문지 Vol.13 No.12
본 연구에서는 백연방지용 냉각탑의 공기가열기 적용을 목적으로 현재 냉각탑의 충진재로 적용되고 있는 쉐브론형, 웨이브형 그리고 딤플형 전열판 형상에 대한 수치해석을 수행하였다. 해석 결과 동일 소비동력 대비 전열 량은 평판보다 고성능 전열판에서 높게 나타났다. 열전달계수는 웨이브 형상에서 가장 크고 쉐브론 형상, 딤플 형상 순으로 나타났다. 웨이브 형상의 경우 교차하는 절곡형상 사이의 왕성한 혼합유동이 열전달 계수를 증진시킨 것으로 판단된다. 마찰계수는 열전달계수와 유사한 경향을 보였다. 하지만 동일 크기 쉬트에서의 전열량 및 압력손실은 쉐브 론형에서 가장 크게 나타났다. 이는 쉐브론 형상의 전열면적이 다른 형상에 비하여 월등히 크기 때문이다. In this study, numerical analysis was performed on three shapes of heat transfer plates (chevron, wave and dimple type), which are currently used as fillers of cooling towers. Results show that heat transfer rates per consumed power were larger for enhanced plates as compared with that of plain plate. Highest heat transfer coefficient was obtained for wave shape followed by chevron and dimple shape. For wave shape, cross corrugations induced significant mixing of fluids, which enhanced the heat transfer. Friction factor yielded a similar trend with the heat transfer coefficient. However, heat transfer rate and pressure drop per sheet was the largest for chevron shape, due to the largest heat transfer area per sheet.
이을종(Lee, Eul-Jong),김내현(Kim, Nae-Hyun) 한국산학기술학회 2015 한국산학기술학회논문지 Vol.16 No.5
본 연구에서는 가습소자 개발을 목적으로 절곡형상이 전열판의 성능에 미치는 영향을 수치해석적으로 검토하였다. 수치해석은 절곡각을 변화시키며 (0o/0o에서 60o/60o사이의 등각도와 15o/0o에서 15o/60o사이의 엇각도) 수행되었다. 해석 결과 j와 f 인자 모두 절곡각이 증가할수록 증가하였다. 특히 f 인자는 절곡각이 큰 영역에서 급격히 증가하였다. 엇각도 전열판의 j, f 인자와 두 각을 평균내어 구한 등각도 전열판의 j, f 인자는 거의 같은 값을 나타내었다. 한편 동일 소비동력 대비 열전달 량을 나타내는 j/f ⅓의 경우 15o/15o에서 가장 크게 나타났다. 기존 상관식은 본 수치해석 결과를 과대 또는 과소예측하였다. In this study, the effect of corrugation angle on thermal performance of corrugated plate is numerically investigated with an aim to develop humidifying element. Numerical analysis was conducted for a range of corrugation angle (from 0o/0o to 60o/60o for equal angle and from 15o/0o to 15o/60o for unequal angle). Results revealed that both j and f factor increased as corrugation angle increased. Especially, f factor increased significantly at high corrugation angles. j and f factors of unequal angle plates and those of equal angle (obtained by averaging unequal angles) plates were approximately the same. The largest ?/f1/3, which implies the largest heat transfer rate per consumed power, was obtained at 15o/15o. Existing correlations under- or over-predicted the present numerical results.
알루미늄 평행류 열교환기 헤더 내 냉매 분배에 관한 연구
이을종(Eul-Jong Lee),김도영(Do-Young Kim),김내현(Nae-Hyun Kim),김수환(Su-Hwan Kim),변호원(Ho-won Byun) 대한설비공학회 2009 대한설비공학회 학술발표대회논문집 Vol.2009 No.-
The refrigerant R-134a flow distributions are experimentally studied for a round header/ten flat tube test section simulating a brazed aluminum heat exchanger. Three different inlet orientations (parallel, normal, vertical) were investigated. Tests were conducted with downward flow for the mass flux from 70 to 130 ㎏/㎡s and quality from 0.2 to 0.6. In the test section, tubes were flush-mounted with no protrusion into the header. It is shown that normal and vertical inlet yielded approximately similar flow distribution. At high mass fluxes or high qualities, however, slightly better results were obtained for normal inlet configuration. The flow distribution was worst for the parallel inlet configuration. Possible explanation is provided based on flow visualization results.
종횡비가 다른 납작관 열교환기내 응축열전달 및 압력손실
박지훈(Ji Hoon Park),이을종(Eul Jong Lee),차상진(Sang Jin Cha),이정표(Jung Pyo Lee),김내현(Nae Hyun Kim) 대한기계학회 2010 대한기계학회 춘추학술대회 Vol.2010 No.5
본 연구에서는 7㎜ 평활관과 종횡비가 다른 납작관의 응축 열전달계수와 압력손실에 관한 실험적 연구를 진행하였다. 실험은 R-410A를 사용하여 포화온도 45℃에서 열유속을 10㎾/㎡K로 고정하고 질량유속과 건도를 각각 400~100㎏/㎡s, 0.2~0.8로 변화시키며 진행하였다. 실험결과 질량유속이 높은 400㎏/㎡s에서는 종횡비가 높아질수록 열전달계수가 증가하였다. 하지만, 낮은 질량유속에서는 관내 종횡비의 영향을 받지 않는 것으로 나타났다. 관내 압력손실은 질량유속과 건도가 높을수록 증가하는 것으로 나타났다. In this study, condensation heat transfer coefficients of R-410A were obtained in a 7㎜ smooth tubes having different aspect ratio. The test range covered saturation temperature 45℃, heat flux 10㎾/㎡K, mass flux 400~100㎏/㎡s and quality 0.2~0.4. The results showed that condensation heat transfer coefficient and pressure drop increased as aspect ratio increased at mass flux 400㎏/㎡s. At lower mass fluxes, condensation heat transfer coefficients weren't effected by aspect ratio. Pressure drop in the tubes increased with the aspect ratio.