이승재(SeungJea Lee),이성준(SungJoon Lee),권혁준(HyuckJun Kwon),이길용(GilYong Lee),여한승(HanSeung Yeo) 대한설비공학회 2021 대한설비공학회 학술발표대회논문집 Vol.2021 No.6
This study attempted to compare the installation standards for firefighter entry windows determined by the Ordinance of the Ministry of Land, Infrastructure and Transport with Japanese standards, not another regulation for companies, but for safety matters. Among these installation standards, which are expected to be implemented in August 2021, the total thickness is limited to 24mm or less when it is composed of double-glazed glass to secure firefighters entry, which is causing a lot of controversy. In particular, the Japanese Standards added items to be considered in order to improve the accessibility, such as the film type and thickness, as well as the thickness of the glass. Therefore, it is necessary to consider the regulations of the entry window for firefighters that are easy to enter.
지진계측 기록을 이용한 저수지 지진응답가속도 증폭 특성 분석
이무재(Moojae Lee),김용성(Yongseong Kim),타망비벡(Bibek Tamang),이승주(Seungjoo Lee),이길용(Gilyong Lee),허준(Joon Heo) 한국지반신소재학회 2020 한국지반신소재학회 논문집 Vol.19 No.4
본 연구에서는 지진가속도 계측기의 계측 데이터를 사용하여 저수지의 동적해석방법에 대한 모형 검정 및 저수지 높이에 따른 지진가속도 증폭 특성을 분석하였다. 모형을 검정하기 위해 댐 기초의 계측 데이터를 입력 데이터로 사용하였고 해석결과를 댐 상부의 계측 데이터와 비교한 결과 수치해석을 이용해 출력된 지진파와 계측 지진파의 최댓값과 그 파형이 비슷하게 나타났고 지진가속도 증폭 특성의 경우 지진가속도 증폭비는 저수지의 높이와 지진의 크기에 비례하는 것으로 나타났다. 본 연구를 통해 저수지에 설치된 가속도계에서 얻은 계측 데이터를 활용하여 반복 탄소성 구성식을 이용한 동적해석방법은 지진파 특성 분석이 적절하게 수행될 수 있는 기법임을 확인하였고 향후 이러한 기법을 적용해 저수지의 지진가속도 계측기의 활용도를 제고할 수 있을 것으로 판단된다. In this study, the model test of a reservoir was performed through a dynamic analysis method by using the data obtained from seismometers. Besides, we analyzed the behavior of the seismic acceleration amplification by reservoir height. To test the model, the data measured by the seismometers were applied at the foundation of the reservoir as input data, and the results from the analysis were compared with the data measured at the dam crest. The analysis results manifest that the peak values and the trend of the seismic wave obtained from the numerical analysis are in good agreement with the measured data. Also, the acceleration amplification ratio was proportional to the reservoir height and the magnitude of the earthquake. Through this study, the dynamic analysis method, which is based on the cyclic elastoplastic constitutive equation, can be considered as an appropriate technique to analyse the seismic behavior by the application of the data obtained from the seismometers installed in the reservoir. Also, the applicability of the seismometers can be enhanced through this technique in the future.
물류시설의 화재하중 및 등가화재지속시간 산출에 관한 연구
이상범(Sangbum Lee),서희원(Heewon Seo),김대회(Daehoi Kim),이길용(Gilyong Lee) 한국방재학회 2023 한국방재학회논문집 Vol.23 No.6
Logistics facilities differ significantly from general buildings in terms of diffusion flame prevention technology, necessitating the application of fire diffusion prevention technology. The total fire load in a fire compartmentation was calculated according to the method presented in The NFPA (The National Fire Protection Association) Fire Protection Handbook, based on the results of a survey on the area, height, and rack dimensions of 29 logistics warehouses in Korea to improve the fire compartmentation standard. In addition, simulations were conducted using CFAST (Consolidated Fire and Smoke Transport) for the cross-validation of these methodologies. Through fire simulations, the temperature of the upper part of each fire compartment was derived, and the equivalent fire duration was calculated by converting it to an area based on the standard time-heating temperature curve of KSF 2257-1. The NFPA methodology and values calculated through fire simulations showed similar results. In addition, we analyzed the tendency of the equivalent fire duration according to the height of the fire compartmentation and confirmed that the higher the floor height, the higher the equivalent fire duration. The results of this study can be used as basic data for improving the fire prevention standards by calculating the equivalent fire duration according to the fire load of a logistics facility and for confirming the tendency of the equivalent fire duration according to the height of the fire compartment. 물류시설은 화재 확산 방지 기술 측면에서 일반 건축물과 매우 다르며, 이를 고려한 화재 확산 방지 기술의 적용이 필요하다. 방화구획 기준 개선을 위해 국내 총 29개 물류창고의 방화구획 내의 면적, 높이, 랙의 치수 등에 대한 조사한 결과를 바탕으로 NFPA Fire Protection Handbook에서 제시된 방법에 따라 방화구획 내의 총 화재하중을 산출하여 등가화재시간을 산출했다. 또한 이러한 방법론의 교차검증을 위해 CFAST (Consolidated Fire and Smoke Transport)를 통한 시뮬레이션을 진행했다. 화재시뮬레이션을 통해 방화구획 별 시간에 따른 상층부의 온도를 도출하고 이를 KS F 2257-1의 표준 시간-가열 온도 곡선에 의한 면적과 등가 환산하여 등가화재지속시간을 산출했다. 그 결과 NFPA (The National Fire Protection Association)의 방법론과 화재시뮬레이션을 통해 산출된 값이 유사한 결과를 나타내었다. 또한 방화구획의 높이에 따른 등가화재지속시간에 대한 경향성 또한 확인해 보았으며 층고가 높을수록 등가화재지속시간이 높은 경향성을 보이는 것을 확인할 수 있었다. 본 연구 결과는 물류시설의 화재하중에 따른 등가화재지속시간을 산출하고 방화구획 높이에 따른 등가화재 지속시간의 경향성을 확인함으로써 방화구획 기준 개선에 기초자료로 활용될 수 있을 것이라 판단된다.
공동주택 강철제 방화문 도어록 부위의 결로방지성능 특성
여한승(Hanseung Yeo),이길용(Gilyong Lee),서보열(Boyoul Seo),최동호(Dongho Choi) 대한설비공학회 2018 대한설비공학회 학술발표대회논문집 Vol.2018 No.11
공동주택에 설치되는 세대현관문과 대피공간 방화문에 대해, 국토교통부에서는 2013년 12월 27일에 공동주택 결로 방지를 위한 설계기준을 제정하고, 실내표면온도를 대상으로 온도차이비율 평가지표에 따른 지역별 성능기준만으로 결로 저감을 유도토록 하고 있지만, 실제로는 해당 성능기준을 충족하더라도 결로형상이 발생할 가능성이 있다(1). 특히 세대 입주 시 디지털 도어록이 설치되는 도어록 부위는 결로가 발생할 경우, 입주자 안전과 방범에 영향을 미칠 수 있는 오작동의 개연성이 높아질 수 있어, 겨울철 마다 언론에 디지털 도어록 오작동에 따른 뉴스가 보도되고 있다(2). 따라서, 본 연구에서는 결로방지 성능기준을 충족한 강철제 방화문을 대상으로 도어록 부위의 결로발생 여부를 확인하고, 도어록 부위에 대한 단열 보강과 디지털 도어록의 시험방법에 대한 개선방안을 제안하고자 한다.
저방사 박막 복합 단열재 두께별 외단열 시공벽체의 단열성능 평가
여한승(Hanseung Yeo),이길용(Gilyong Lee),정재군(Jaegun Jeong) 대한설비공학회 2019 대한설비공학회 학술발표대회논문집 Vol.2019 No.-
건축물 에너지절약설계기준의 단열성능 강화에 따라 단열재 성능기준이 상향되고 건축자재 화재안전성능 강화로 인해 기존 부피형 단열재 사용이 어려워지고 있다. 이에 따라 알루미늄 필름과 타공형 폴리에틸렌폼이 주요 구성재료인 저방사 박막 복합 단열재가 중소규모 건물 등을 중심으로 폭넓게 설치되고 있지만, 실제 현장에 설치되는 구성재료와 동일한 시료에 대한 단열성능 평가는 전무한 상황이다. 따라서, 본 연구에서는 6개 제조사 제품 50개 저방사 박막 복합 단열재의 두께별, 난연성 유무 및 공기층 유무에 따른 시공벽체의 단열성능을 평가함으로써 저방사 박막 복합 단열재 두께와 단열성능 간의 상관관계를 파악했으며, 제조사 기술력과 품질관리 능력에 따른 차이가 큰 것을 확인할 수 있었다.
공동주택 방화문의 경년변화 추정을 위한 성능평가 방법 고찰
여한승(Hanseung Yeo),이길용(Gilyong Lee),왕남웅(Namwoong Wang),정재군(Jaegun Jeong) 대한설비공학회 2019 대한설비공학회 학술발표대회논문집 Vol.2019 No.11
Front doors and fire doors in the shelter space to be installed in apartment houses require the most performance among construction materials, including the need to secure thermal insulation and condensation prevention performance, in addition to the fireproof performance, the fundamental performance as fire doors. Recently, damages claims for lack of fireproofing performance of fire doors have been spread in apartment houses across the country, and actual installed fire doors have been dismantled and tested for performance, affecting court rulings. However, it is controversial whether the performance of the fire doors will be reduced due to damage to the fire doors or annual variation. As the criteria for the actual conditions of use are not available, the test is conducted on different test specimens for each required performance, and the actual use and annual change are not reflected. In this study, the required performance of fire doors was classified and performance evaluation methods were proposed for the purpose of utilizing them as basic data necessary for annual variation of fire doors in apartment houses and for the purpose of establishing the life span guidelines.