http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
윤인석,신태영,김선일,박성곤,장현익,최종보,안현수,김영수,김세중 대한비뇨의학회 2013 Investigative and Clinical Urology Vol.54 No.9
Purpose: To investigate whether hospitalization influences serum prostate-specific antigen (PSA) values. Materials and Methods: Transrectal ultrasound-guided prostate biopsies were performed for detecting prostate cancer in 2,017 patients between February 2001 and April 2011 at Ajou University Hospital. Of those patients, 416 patients who were hospitalized for prostate biopsies, whose serum PSA values were measured at the outpatient department within 1 month of admission and also just after admission, and who had negative prostate biopsy results were included in the present study. We retrospectively reviewed the data of the 416 patients and compared the serum PSA values measured in the outpatient department with those measured during hospitalization. Results: Among all 416 patients, the interval between the two PSA measurements was 22.2 days (range, 3 to 30 days) and the prostate size measured by transrectal ultrasonography was 53.63 mL (range, 12.8 to 197.9 mL). Among all patients, mean serum PSA levels measured during hospitalization were significantly lower than those measured in the outpatient department (6.69 ng/mL vs. 8.01 ng/mL, p<0.001). When stratified according to age, the presence or absence of chronic prostatitis in the biopsy pathology, serum PSA levels, and prostate size, the serum PSA levels measured during hospitalization were significantly lower than those measured in the outpatient department in all subgroups, except in cases aged 20 to 39 years and those with PSA <4 ng/mL, in whom no significant differences were shown. Conclusions: Hospitalization decreases serum PSA values compared with those measured on an outpatient basis in patients with benign prostatic diseases. Therefore, serum PSA values should be checked on an outpatient basis for serial monitoring.
Influence of curing condition and carbonation on electrical resistivity of concrete
윤인석,홍성원,강현구 사단법인 한국계산역학회 2015 Computers and Concrete, An International Journal Vol.15 No.6
The electrical resistivity of air-dried, saturated, and carbonated concretes with different mixture proportions was monitored to evaluate and quantify the influence of the age of the specimen, carbonation, and curing condition. After 28 days of curing, four prepared specimens were stored in a vacuum chamber with 5% CO2 for 330 days to make carbonated specimens. Four of the specimens were placed in water, and four specimens were cured in air until the end of the experiments. It was observed that the electrical resistivity of the carbonated specimens increased as carbonation progressed due to the decrease of porosity and the increase of hydrated products. Therefore, in order to estimate the durability of concrete, its carbonation depth was used as the measurement of electrical resistivity. Moreover, an increase of electrical resistivity for air-dried and saturated concretes was observed as a function of age of the specimen. From the relationship between chloride diffusivity provided by Yoon et al. (2007) and the measurements of electrical resistivity, it is expected that the results well be of significant use in calibrating chloride diffusivity based on regular measurements of electrical resistivity during concrete construction.