http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
UV/persulfate에 의한 methylated arsenic 산화 연구
윤성환 ( Sung Hwan Yoon ),김태훈 ( Tae Hun Kim ),이면주 ( Myun Joo Lee ),유승호 ( Seung Ho Yu ) 한국공업화학회 2009 응용화학 Vol.13 No.1
UV/persulfate 반응을 이용하여 메틸화 유기비소의 산화연구를 수행하였다. UV/persulfate에 의한 메틸화 유기비소의 산화효율은 UV/H2O2보다 높은 것으로 나타났다. 또한 persulfate의 농도 또는 용액의 온도를 증가시킴으로써 UV/persulfate에 의한 메틸화 유기비소의 산화효율을 증가시킬 수 있었다. 본 연구의 결과는 sulfate radical(SO4-·)이 메틸화 유기비소의 산화에 매우 효과적임을 보여준다. The oxidation of methylated arsenic in aqueous solution was investigated using UV/persulfate reaction. The performance of UV/persulfate was higher than that of UV/H2O2. The oxidation efficiencies of methylated arsenic by UV/persulfate were increased with the increase in persulfate concentration or solution temperature. The results indicate that sulfate radical (SO4-·) is very effective for the oxidation of methylated arsenic.
전기장이 인가된 건축물 화재에서 화재연기에 관한 실험적 연구
유승우(Seung Woo Yoo),김양균(Yangkyun Kim),심재웅(Jae-Ung Sim),윤성환(Sung Hwan Yoon) 한국화재소방학회 2021 한국화재소방학회 학술대회 논문집 Vol.2021 No.추계
화재 사상비율 중 유독가스에 의한 사상은 가장 높은 비율을 차지하고 있으며, 이는 대부분 CO 에 의해 발생한다. 유독가스는 높은 확산속도를 가지며 유독가스의 방향성은 피난자에게 중대한 영향을 미친다. 현재 대부분의 건축물은 탄화수소 계열의 스티로폼 단열재부터 페놀폼, 폴리우레탄폼까지 다양한 단열재를 사용하고 있다. 이들은 연소과정 중 다량의 CO가 발생하며, 대형화재가 일어날 경우 유독가스로 인한 많은 사상자를 발생한다. 탄화수소 화염은 양전하와 음전하를 발생시키는데 이에 전기장을 인가할 경우 로렌츠 힘에 의해 양전하와 음전하가 각 전극으로 이동하며 주위 중성자에게 운동량을 확산시켜 체적유동을 유발한다. 이런 중성자들의 움직임을 ‘이온풍’ 이라 하는데 CO 와 같은 중성자의 유동방향을 제어한다면 피난자의 피난시간을 확보할 수 있을 것이다. 보다 자세한 내용은 구두발표를 통하여 논의하겠다.
UV-A, UV-C 와 VUV를 이용한 Trimethoprim의 분해
김태훈 ( Tae Hun Kim ),윤성환 ( Sung Hwan Yoon ),최동규 ( Dong Kyu Choi ),이면주 ( Myun Joo Lee ),유승호 ( Seung Ho Yu ) 한국공업화학회 2009 응용화학 Vol.13 No.1
The degradation of trimethoprim(TRI) in aqueous solution was investigated using three kinds of low-pressure mercury lamps: UV-A (352nm). UV-C (254nm) and VUV (l85nm and 254nm). The maximum absorption wavelength of the TRI at a concentration of 30mg/L in aqueous solution is 285nm with spectrophotometer. With the irradiation of UV-lamps for 120min, the degradation rates of the parent compounds showed 0 % with UV-A, 20% with UV-C and 88% with VUV. respectively. This results indicate that VUV is the most effective process for the degradation of antibiotic among UV-A, UV-C and VUV.
권순형(Soon Hyeong Kwon),윤성환(Sung Hwan Yoon),이대근(Dae Geun Lee),김승곤(Seung Gon Kim),곽영태(Young Tae Guahk),차민석(Min Suk Cha),박정(Jeong Park),정석호(Suk Ho Chung) 한국연소학회 2019 KOSCOSYMPOSIUM논문집 Vol.2019 No.5
Generally, charged particles are generated in hydrocarbon flames. When the electric field is applied, positive and negative charges travel to the anode and cathode, respectively. The process of positive charge moving to cathode has been well known, but the process of negative charges moving to anode is not clear. In this experiment, direct current electric fields were applied with orthogonal to each side of the flame to study the movement of negative charges on the anode side.
최우진 ( Woo Jin Choi ),윤성환 ( Sung Hwan Yoon ),승나르 ( Na Reu Seung ),박은주 ( Eun Ju Park ),조희진 ( Hee Jin Jo ),김광호 ( Kwang Ho Kim ),김광중 ( Kwang Joong Kim ) 大韓皮膚科學會 2010 大韓皮膚科學會誌 Vol.48 No.1
A nevus with cyst is defined as a single lesion of a melanocytic nevus, and this is commonly associated with an epidermal cyst. For the previously reported cases of a nevus with cyst, most of the melanocytic nevi were of the intradermal or compound type. There have been rare reported cases of dysplastic nevus, blue nevus, Spitz nevus, congenital melanocytic nevus and so forth. We report here on a rare case of congenital melanocytic nevus combined with an epidermal cyst in a 21-year-old woman. (Korean J Dermatol 2010;48(1):72∼74)
김준석(Jun Seok Kim),유승우(Seung Woo Yoo),김양균(Yangkyun Kim),심재웅(Jae-Ung Sim),윤성환(Sung Hwan Yoon) 한국화재소방학회 2022 한국화재소방학회 학술대회 논문집 Vol.2022 No.춘계
대한민국 뿐만 아니라 전세계적으로 건축물의 단열재는 탄화수소 계열의 스티로폼 단열재, 페늘품, 폴리우레탄 등 다양한 단열재를 사용하고 있다. 이러한 단열재들은 화재 발생 시 다량의 CO가 발생하며, 다량의 CO는 재실자들의 안전을 위협한다. 화재 사상 비율 중 유독가스에 의한 사상은 가장 높은 비율을 차지하고 있기 때문에 화재 발생 시 발생되는 유독가스의 제어는 재실자의 피난시간을 확보할뿐만 아니라 사상률 또한 감소시킬 수 있다. 본 연구에서는 전기장을 활용한 새로운 방식의 화재연기 제어 방법을 제안하고자 한다. 일반적으로 건축물 내 화재 발생 시 스프링클러 등 물을 통해 화재를 제어하는 설비 시설이 구축되어 있으나 화재 연기를 제어하는 방법의 설비는 미비하다. 건축물 단열재로부터 발생되는 탄화수소 계열의 화염은 연소 시 양전하와 음전하를 발생시키며 동시에 전기장을 인가하게 될 경우, 양전하와 음전하는 각각 음극과 양극으로 가속하며 대부분의 수밀도를 차지하는 중성자들에게 운동량을 확산시킨다. 이러한 중성자들이 야기하는 다량의 체적유동을 ‘이온풍’이라 정의하며 이온풍을 통해 화재 연기를 한쪽 방향으로 제어하고자 한다. 실험 방식은 가로, 세로, 높이가 모두 17 cm인 정사각형 아크릴 챔버를 설치하였고, 내부 중앙에서 탄화수소 계열의 스티로폼 단열재를 시료로 채택하여 화재를 발생시키게 된다. 정사각형 아크릴 챔버 한쪽 방향으로 재실자의 피난로를 모사한 아크릴 통로를 설치하였으며 전기장을 인가하기 위해 metallic mesh를 설치하였다. 전기장을 인가하지 않고 화재를 발생시킬 경우 buoyancy effect로 인해 챔버 상부로 연기가 발생되게 된다. 전기장의 세기는 각각 ± 2, 5 그리고 10 kV를 인가하였고, 각 전기장 세기마다 발생되는 화재연기 제어 효과를 비교하였다. 실험결과에 관한 자세한 설명은 구두 발표로 대체하고자 한다.