http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Kanai-Tajimi 필터 인공지진 가진된 마찰형 감쇠를 갖는 구조물의 변위 응답 확률분포
윤경조,박지훈,민경원,이상현,Youn, Kyung-Jo,Park, Ji-Hun,Min, Kyung-Won,Lee, Sang-Hyun 한국전산구조공학회 2007 한국전산구조공학회논문집 Vol.20 No.5
The accurate peak response estimation of a seismically excited structure with frictional damping system(FDS) is very difficult since the structure with FDS shows nonlinear behavior dependent on the structural period, loading characteristics, and relative magnitude between the frictional force and the excitation load. Previous studies have estimated that by replacing a nonlinear system with an equivalent linear one or by employing the response spectrum obtained based on nonlinear time history and statistical analysis. In the case that an earthquake load is defined with probabilistic characteristics, the corresponding response of the structure with FDS has probabilistic distribution. In this study, nonlinear time history analyses were performed for the structure with FDS subjected to artificial earthquake loads generated using Kanai-Tajimi filter. An equation for the probability density function (PDF) of the displacement response is proposed by adapting the PDF of the normal distribution. Finally, coefficients of the proposed PDF are obtained by regression analysis of the statistical distribution of the time history responses. Finally the correlation between PDFs and statistical response distribution is presented. 마찰형 감쇠를 갖는 구조물은 구조물의 고유주기, 하중의 특성, 그리고 외부하중에 대한 마찰력의 상대적인 크기에 따라 강한 비선형성을 나타내므로, 구조물의 최대응답을 예측하기 매우 어렵다. 기존의 연구에서는 비선형 시스템을 등가의 선형 시스템으로 치환하거나, 구조물의 비선형 시간이력해석을 통한 응답스펙트럼 분석에 의한 간단한 확률해석에 의해 수행되었다. 지진 하중은 불확실성과 불규칙성을 갖고 있기 때문에 확률적으로 정의된다면, 지진하중을 받는 마찰형 감쇠를 갖는 구조물의 응답 역시 확률분포를 나타낼 것이다. 본 논문에서는 Kanai-Tajimi 필터를 이용해 생성된 인공지진하중에 대해 마찰형 감쇠를 갖는 구조물의 비선형 시간이력 해석이 수행되었다. 그리고 정규분포 확률밀도 함수에 선형 회귀분석을 통해 얻어진 구조물의 주기와 마찰력의 크기에 의한 변수를 업데이트 시킨 마찰형 감쇠를 갖는 구조물의 변위 응답 확률밀도함수식이 제시된다.
분산제어식 응답의존형 MR 감쇠기를 이용한 구조물의 지진응답제어
윤경조,민경원,이상현,Youn, Kyung-Jo,Min, Kyung-Won,Lee, Sang-Hyun 한국전산구조공학회 2007 한국전산구조공학회논문집 Vol.20 No.6
In centralized control system, complicated control systems including sensors, power supply and dampers should be required to satisfy the target response of large-scale structures. The practical applications of the centralized control system, however, is very difficult due to high order finite element model of structures, uncertainty of models, and limitations of the excitation system. In this study, the decentralized response-dependent MR damper of which magnetic field is automatically modulated according to the displacement or velocity transferred to the damper without any sensing and computing systems. this decentralized response-dependent MR damper are investigated according to the ranges of relative magnitude between the control force of MR damper and the story shear force of structures by nonlinear time history analysis. Finally, its performance is compared with centralized LQR algorithm which is used in general centralized control theory for a three story building structure. 건축 및 토목 구조물의 진동 제어분야에서 중앙집중식 제어방식은 주어진 목표응답수준을 만족시키기 위해서 전력공급, 센서, 그리고 감쇠기 등을 포함하는 복잡한 제어시스템을 구축하고 유지하는 노력이 필요하고, 구조물 유한요소모델의 큰차수, 모델의 불확실성, 가력장치의 제한 등의 이유로 적용성의 한계가 있다. 본 논문에서는 센서 혹은 컴퓨터없이 준능동 MR 감쇠기가 설치된 층만의 정보에 의해 제어력이 생성되는 분산제어식 응답의존형 MR 감쇠기가 제안하였다. 제안된 분산제어식 응답의존형 MR 감쇠기는 구조물의 층전단력에 대한 가변마찰력 크기 비의 변화에 따라 지진하중을 받는 구조물의 제어성능이 수동인 경우와 비선형 시간이력해석을 통해 비교 평가되었다. 마지막으로 일반 제어이론에서 널리 이용되는 중앙집중식 LQR 알고리듬과 본 논문에서 제안된 분산제어식 응답의존형 MR감쇠기가 3층 전단형 구조물을 대상으로 수치해석을 통해 비교 평가됨으로써 제안된 알고리즘의 유효성을 검증하였다.
준능동 MR감쇠기가 설치된 실물크기 구조물의 분산제어 알고리즘 성능평가
윤경조(Youn, Kyung-Jo),박은천(Park, Eun-Churn),이헌재(Lee, Heon-Jae),문석준(Moon, Seok-Jun),민경원(Min, Kyung-Won),정형조(Jung, Hyung-Jo),이상현(Lee, Sang-Hyun) 한국소음진동공학회 2008 한국소음진동공학회 논문집 Vol.18 No.2
In this study, seismic response control performance of decentralized response-dependent MR damper which generates the control force using only the response of damper-installed floor, was experimentally investigated through the tests of a full-scale structure installed with large MR dampers. The performance of the decentralized control algorithm was compared to those of the centralized ones such as Lyapunov, modulated homogeneous friction, and clipped-optimal control. Hybrid mass damper were controlled to induce seismic response of the full-scale structure under El Centro earthquake. Experimental results indicated that the proposed decentralized MR damper provided superior or equivalent performance to centralized one in spite of using damper-installed floor response for calculating input voltage to MR damper.
박지훈(Park, Ji-Hun),윤경조(Youn, Kyung-Jo),민경원(Min, Kyung-Won),이상현(Lee, Sang-Hyun) 한국소음진동공학회 2007 한국소음진동공학회 논문집 Vol.17 No.1
Structures with additional frictional damping system have strong nonlinearity that the dynamic behavior is highly affected by the relative magnitude between frictional force and excitation load. In this study, normalized response spectra of the structures with non-dimensional friction force are obtained through nonlinear time history analyses of the mass-normalized single degree of freedom systems using 20 ground motion data recorded on rock site. The variation of the control performance of frictional damping system is investigated in terms of the dynamic load and the structural natural period, of which effects were not considered in the previous studies. Least square curve fitting equations are presented for describing those normalized response spectrum and optimal non-dimensional friction forces are obtained for controlling the peak displacement and absolute acceleration of the structure based on the derivative of the curve-fitted design spectrum.
실시간 하이브리드 실험법을 이용한 대형 MR감쇠기의 제진 성능평가
박은천(Park, Eun-Churn),이성경(Lee, Sung-Kyung),윤경조(Youn, Kyung-Jo),정희산(Chung, Hee-San),이헌재(Lee, Heon-Jae),최강민(Choi, Kang-Min),문석준(Moon, Suk-Jun),정형조(Jung, Hyung-Jo),민경원(Min, Kyung-Won) 한국소음진동공학회 2008 한국소음진동공학회 논문집 Vol.18 No.1
This paper presents real-time hybrid test method of large-scale MR damper applied to a building structure under seismic excitation. The real-time hybrid test using an actuator for the control performance evaluation of a MR damper controlling the response of earthquake-excited building structure is experimentally implemented. In the test, the building structure is used as a numerical part, on which a large-scale MR damper adopted as an experimental part was installed to reduce its response. At first, the force that is acting between a MR damper and building structure is measured from the load cell attached on the actuator system and is fed-back to the computer to control the motion of the actuator. Then, the actuator is so driven that the error between the interface displacement computed from the numerical building structure with the excitations of earthquake and the fed-back interface force and that measured from the actuator. The control efficiency of the MR damper used in this paper is experimentally confirmed by implementing this process of experiment on real-time.