복합 공간 구성 건물의 공조구역 운영 전략에 따른 에너지부하 특성 연구
육인수(In Soo Yook),김민환(Min Hwan Kim),남현진(Hyeon Jin Nam),김동호(Dong Ho Kim),설동문(Dong Mun Seol),이건태(Geon-Tae Lee),김진호(Jin-Ho Kim),김재민(Jae Min Kim) 대한설비공학회 2009 대한설비공학회 학술발표대회논문집 Vol.2009 No.-
Buildings with multi-complex spaces designed for architectural values and functional requirements give rise to technical challenges in terms of energy efficiency and thermal comfort. Since spaces in such buildings are connected with openings with geometrical complexity, it is hard to define zoning plan and to control heating/cooling loads effectively. This paper presents a case study on the evaluation of operation strategy for a building with multi-complex spaces using computer simulation. The modelling methodology and the results of the simulations are also described.
신동혁,성주현,육인수,이명구,오태근,Shin, Dong Hyuk,Seong, Joo Hyun,Yook, In Soo,Lee, Myeong-Gu,Oh, Tae Keun 한국안전학회 2017 한국안전학회지 Vol.32 No.4
Among various methods to build the construction safety, the consecutive improvement by the measuring and evaluating safety management capabilities for the construction participants such as an owner, a contractor, and a supervisor (construction project manager) can be the effective one. Thus, an effective evaluation and grading criteria to provide performance index for the implementation of safety management activities should be necessary. In this regards, the purpose of this study is to verify the adequacy by offering a competency evaluation system for the supervisor's safety capability and by applying the system to some construction sites. The proposed evaluation system was developed on the basis of the principles of safety management & accident prevention, basic elements of safety and health management system, and safety evaluation cases at home and abroad. The trial evaluation showed that the safety management of the construction site is mainly carried out by the contractor and the supervisor's awareness for the safety management is low on the whole. Especially, it is urgent to improve the support system from the supervisor headquarter and to place the dedicated safety management person in the field.
이중창 시스템 적용성 평가를 위한 시뮬레이션 모델링 기초 연구
남현진(Nam Hyun-Jin),김은희(Kim Eun-Hee),육인수(Yook In-Soo),김동호(Kim Dong-Ho),정광섭(Chung Kwang-Seop),김재민(Kim Jae-Min) 한국건축친환경설비학회 2008 한국건축친환경설비학회 학술발표대회 논문집 Vol.- No.-
As double facade systems are adopted for energy saving in curtain wall buildings, their performance are often evaluated with detailed computer simulation. the results derived from inappropriate models are likely to lead to wrong decision. when applying simulation models, preliminary tests should be made to define appropriate model. In this study, a the energy performance of a proposed double window system was tested with ESP-r simulation. To implement this test, different scaled air-flow network models were produced, and their results were compared. It was identified that the energy performance of the proposed double window systems varies depending on the modelling strategies. The error rate between different scaled models is about 15%. It is important to consider appropriate modelling strategy compromising efficiency with accuracy.