http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
백남춘(Baek Nam-Choon),윤종호(Yoon Jong-Ho),윤응상(Yoon E. S),유창균(Yoo C. G),주문창(Joo M. C),손선우(Son S. W) 한국태양에너지학회 2007 한국태양에너지학회 학술대회논문집 Vol.- No.-
This study is on the evaluation of KIER Zero Energy Solar House(ZeSH). This ZeSH was designed and constructed for the goal of 70% self sufficiency only thermal loads. Various innovative technologies for reducing thermal load such as super insulation, high performance window, passive solar systems, ventilation heat recovery system , etc are applied in this ZeSH. In this study, the performance of the active solar heating system with geothermal heat pump as an auxiliary energy system and the energy self sufficiency rate are especially analyzed by experiment. Indoor setting temperature of ZeSH is 20℃ throughout the experimental period. As a result, the performance of active solar system is 35 to 40% depending on the various ambient condition and the solar fraction for heating season is about 74%.