RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Research Paper : A Genotypical Analysis of Korean REMCs and Generation of Base Line Data for the Analysis and Evaluation for Future (REMCs) Designs Using Space Syntax

        울라우바이드 ( Ubaid Ullah ),박재승 ( Jae Seung Park ) 한국의료복지건축학회(구 한국의료복지시설학회) 2016 의료·복지 건축 Vol.22 No.1

        Purpose: The purpose of this paper is to analyze the spatial configurations of a sample of Korean regional emergency medical centers (REMCs) to explore its underlying genotypes and thus produce a base line data for the analysis and evaluations of future REMCs designs using space syntax theory. Methods: Space syntax analysis was used as a major tool for the analysis and exploration of Genotype. The measures of Integration(overall integration with exterior and without exterior as well as the integration of individual clinical spaces for each center), base difference factor (DF) and Space link ratio were calculated for a sample of seven Korean REMCs. Results: The result shows a strikingly similar pattern of Syntactic measures across the sample, the mean integration of sample ranges from 0.82-0.99 with exterior (while considering the exterior space as a root) and 0.81-1.01 without exterior (considering the connections of interior spaces only with no outside connection). The base difference factor (DF) of the sample varies from 0.60-0.81 with exterior and from 0.59-0.82 without exterior. Case number-1 was identified as non-genotype with differing order of Syntactic values. Although the genotype had different forms, layouts and even sizes, these results cannot be explained by Phenotypical comparisons. Implications: This study will contribute to the configurational analysis and evaluation of existing and future Korean REMCs design and practice of emergency healthcare delivery system in Korea.

      • KCI등재

        A Study on the Development of Predictive Model for Patient Visibility in Korean Intensive Care Units (ICUs) - Focused on “Corridor or Continental” type units

        울라우바이드 ( Ullah Ubaid ),박재승 ( Park Jae Seung ) 한국의료복지건축학회(구 한국의료복지시설학회) 2016 의료·복지 건축 Vol.22 No.3

        Purpose: The purpose of this paper is to develop a predictive model for patient visibility in Korean ICUs (corridor or continental type). Methods: The measures of static visibility were used to quantify the patient visibility (upper third part of the patient bed) from the nurse station. The measure of space programme and area distribution (patient zone percentage, staff zone percentage and departmental gross square meter per patient bed) were calculated by using AutoCAD and MS Excel programs. Regression analysis was conducted for visibility as dependant variable with independent variables of patient area percentage, staff area percentage as well as departmental gross square meter per bed by using IBM SPSS. Results: (1) Average patient visibility and percentage of patient area in ICU shows a strong negative correlation (r²=0.66), p=0.01. (2) Patient visibility in Korean ICU (corridor or continental type) can be calculated as below with the given conditions: Y= -1.449(X)+124.3±6, Y is the total visibility of the ICU (corridor or continental type) and X is the percentage of patient area in the unit. Conditions:1. Given that the unit has a mixed programme of open bed and closed patient rooms and 2. The unit have a minimum of 20% patient rooms. Implications: This study may contribute to the visibility analysis of existing and future ICU design (corridor or continental type) in Korea to achieve maximum patient visibility and reduced patient mortality.

      • KCI등재

        A Comparative Analysis of Patient Visibility, Spatial Configuration and Nurse Walking Distance in Korean Intensive Care Units(ICUs) - Focused on single corridor, Pod and Composite type units

        울라우바이드 ( Ullah Ubaid ),박재승 ( Park Jae Seung ) 한국의료복지건축학회(구 한국의료복지시설학회) 2016 의료·복지 건축 Vol.22 No.4

        Purpose: The purpose of this paper is to analyze a sample of single corridor, pod type and composite type of ICUs in terms of patient visibility, spatial configurations and nurse walking distance focused on Korean cases. Methods: The measures of static visibility were used to quantify the patient visibility (upper third part of the patient bed) from the nurse station. The measure of space programme and area distribution (patient zone percentage, staff zone percentage, circulation zone percentage, corridor length per bed, distance from nurse station (NS) to patient bed and departmental gross square meter (DGSM) per patient bed) were calculated by using AutoCAD and MS Excel programs. In the second step of analysis the values of space distribution were compared among the three type of ICUs as well as the nurse walking distance, DGSM per bed and gross factor. in the third step of analysis regression analysis was conducted for the possible correlation between visibility and space programme and area distribution factors as well as nurse walking distance factors. Results: (1) It was found that on average composite type unit offer highest value of patient visibility followed by pod type, while single corridor type unit offers the minimum value of patient visibility among the three plan typologies. (2) Average patient visibility and DGSM per bed shows a strong positive correlation (r²=0.75) and p=0.026. (3) Average patient visibility and average distance from NS has a strong negative correlation (r²=0.78), and P=0.02. (4) On average composite type unit offer the minimum walking distance from NS (7.22 meter) followed by pod type unit (8.35 meter) and single corridor (9.76 meter). (5) Maximum distance from NS was noted in single corridor (18.19 meter) followed by pod type unit (15.14 meter) and Composite type unit (11.1 meter). Implications: This study may contribute to the visibility analysis of existing and future ICU design in Korea to achieve maximum patient visibility and reduced nurse walking distance.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼