뿜칠 피복 원형 철골구조의 비재하 내화성능 평가용 시험체제안을 위한 연구
옥치열,김재준 한국화재소방학회 2016 한국화재소방학회논문지 Vol.30 No.3
The cross-sectional shape factor is used worldwide to evaluate the scientific performance of fire-resistant structures. InSouth Korea, however, a system for applying a cross-sectional shape factor has not been arranged and circular or rectangularsteel pipes are commonly used for large-scale steel frame buildings. On the other hand, coating material-spray steelbeams and pillars that have received the certification of a fire-resistant structure from recognized organizations are mostlylimited to a H-beam. A H-beam is granted a wide range of certifications without size limitations from a non-loading performancetest with test standards based on the relevant provisions. Other types of steel pipe are to be certified for fireresistanceaccording to shape. In this study, a cross-sectional shape factor was used to propose standard testing specificationsfor the application of coating material-sprayed circular and rectangular steel pipes, eventually to set the scope of certificationfor reasonable fire-resistant structures. 단면형상계수는 세계적으로 흔하게 활용되는 공학적 내화구조 성능평가 방법이지만 국내의 경우 단면형상계수의 적용을 위한 제도가 아직 마련되어 있지 못하다. 실제 우리나라의 대부분의 철골조 건축물에서 원형 강관의 사용을 흔히 볼수 있으나, 인정기관으로부터 성능을 인정받은 뿜칠 피복 철골 보 및 기둥은 대부분이 H형강으로 한정되어 있다. 비재하시험의 특성상 H형강은 관련규정에 따른 시험규격으로 부재에 대한 평가를 수행하여 크기의 제한 없이 인정범위가 부여되나, 이형 강관의 경우는 형상별로 별도의 내화성능에 대한 인정을 받아야 한다. 본 연구에서는 합리적인 내화구조의인정범위를 설정할 수 있도록 단면형상계수를 활용하여 뿜칠 피복재의 원형 강관의 적용을 위한 표준 시험체 규격을 제시하고자 한다.
뿜칠피복 각형 강관의 내화성능 평가를 위한 실험적 연구
옥치열,김재준,Ok, Chi-Yeol,Kim, Jae-Jun 한국공간구조학회 2017 한국공간구조학회지 Vol.17 No.1
Structures of steel frame buildings getting vary depending on the development of construction technology. Fire-resistant steel beams and Columns accredited by accreditation bodies from the performance of various fire-resistant coating is applied to the current pillar method is most H-beams. H-beam has been proposed a non-load test specifications in the relevant regulations, its scope of accreditation to be granted without limitation of size H-beams from the performance of the test specification. However, in the case of the rectangular steel structure is to check its performance and to a separate one of the receive acknowledge and so take advantage of the cross-sectional shape factor in this study to test the performance of the fire-resistant structure proposed for standard test specimen.
옥치열(Ok Chi-Yeol),이혜미(Lee Hye-Mi),박진오(Park Jin-O),민병렬(Min Byung-Yeol) 대한건축학회 2008 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.28 No.1(구조계)
Recently, Buildings are getting large in size and have more various uses. For more efficient uses of the inside space in building and fire prevention, These partitions for fire prevention block are installed for additional demand ; structural safety, Fire-resistence, Insulation, Noise-interception Performance. However, partitions used for dividing the space are generally classified into furniture by Korean building regulation and it did not demand the performance of Fire resistence structure for fire prevention block. Furthermore, generally the divided area by partitions is more smaller than fire prevention block area. Also, the existence or nonexistence of fire resistance performance of partition in real fire causes the different result such as diffusion extent of fire, scale of property damages, saving the life and so on. Therefore, it aims to develop the partition has fire resistence performance with the superior workability in this study.
옥치열(Ok, Chi Yeol),박진오(Park, Jin O),전수민(Jeon, Soo Min) 한국화재소방학회 2013 한국화재소방학회 학술대회 논문집 Vol.2013 No.추계
내화구조로 인정을 받은 국내의 철골조 기둥의 경우 대다수가 H형강에 내화제품을 피복한 구조이다. 본 연구에서는 한국산업표준에서 제시하고 있는 단면형상계수를 기준으로 H형강 인정구조와 다양한 단면의 내화구조의 비교실험을 통해 국내 인정제도를 개선하기 위한 자료로 활용하고자 하였다.