http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Long 전극갭을 가지는 AC PDP의 전기광학적특성에 미치는 돌기전극의 영향
許禎恩(Jeong-Eun Heo),玉政于(Jung-Woo Ok),李敦揆(Don-Kyu Lee),李海準(Hae-June Lee),李?駿(Ho-Jun Lee),朴正后(Chung-Hoo Park) 대한전기학회 2008 전기학회논문지 Vol.57 No.8
In the current PDP technology, one of the most important issues in AC PDP is improvement of luminance and luminous efficacy. To improve luminance and luminous efficacy, new cell structure of PDP containing long discharge path is necessary. However, it causes an increment of firing voltage. In order to decrease firing voltage of AC PDP having long discharge gap, the protrusion electrode is proposed. To drop the firing voltage, the protrusion electrode is inserted into the forward area of the main discharge gap. This paper presents measurements of detailed optical and electrical characteristics of AC PDP with protrusion electrodes. The experimental results show that the proposed structure with gap 80㎛ has lower firing voltage to 27V than that of the conventional long gap structure. Moreover, the ICCD(Intensified Charge Coupled Device) images of the proposed structure show quick discharge generation by 0.07usec and longer continuation by 0.05usec than that of the conventional long gap structure. Therefore, the proposed protrusion electrodes have higher luminance by 12.5% than that of the conventional structure, as having no decrement of Luminous efficacy.