RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        팽창 줄눈 특성에 따른 Blow-up 발생시기 및 위치 예측

        안희락,김영규,이승우 한국도로학회 2024 한국도로학회논문집 Vol.26 No.2

        PURPOSES : High temperatures induce excessive expansion in pavements, thus causing the closure of contraction joints between expansion joints. This results in the integration of slabs within the expansion joints into a unified slab. Compressive forces are generated owing to the friction that ensues between the unified slab and lower base layer. As the integrated slab expands and exceeds the allowable width of the expansion joint, the end restraint generates an additional compressive force. The escalating force, which reaches a critical threshold, induces buckling, thus compromising stability and causing blow-up incidents, which poses a significant hazard to road users. The unpredictable nature of blow-up incidents render their accurate prediction challenging because the compressive force within the slab must be predicted and the threshold for blow-up occurrence must be determined. METHODS : In this study, a GWNU blow-up model was developed to predict both the compressive force and period of blow-up incidents in jointed concrete pavements. The climate conditions, pavement structure, materials, and expansion joints were considered in this model. In the first stage of the model, the time at which the integrated slab expanded and surpassed the allowable width of the expansion joint was determined, and the compressive force was calculated. Subsequently, the compressive force within the integrated slab, considering both the end restraints and friction, was predicted. A large-scale blow-up test was performed to measure the blow-up force based on changes in the geometric imperfections. The measured blow-up force was adopted as the blow-up occurrence threshold, and the point at which the predicted compressive force within the slab exceeded the blow-up force was identified as the blow-up occurrence time. RESULTS : Using the GWNU blow-up model, the blow-up occurrence on the Seohean Expressway in Korea is predicted in the presence or absence of the alkali-silica reaction (ASR). Analysis is conducted using the expansion joint spacing and width as variables. As the expansion joint spacing increases, blow-up occurs sooner, and as the width increases, only the expansion joint life decreases. When applying an expansion joint spacing of 300 m and a width of 100 mm under an ASR with 99.9% TTPG reliability, the sum of the expansion joint life and blow-up occurrence time is 16 years. CONCLUSIONS : In the case of jointed concrete pavements where ASR occurred, installing an expansion joint spacing of 300 m and a width of 100 mm does not satisfy the design life of 20 years, and the expansion joint width minimally affect the blow-up occurrence time. To prevent blow-up incidents, a spacing of less than 300 m for the expansion joint is recommended. Based on the analysis results, the blow-up occurrence time and location can be predicted from the characteristics of the installed expansion joint, through which blow-up incidents can be prevented via preliminary maintenance.

      • KCI등재

        미세먼지 전구체 저감 소재의 기존 콘크리트 구조물 고정화를 위한 기초연구

        안희락,김영규,이승우 한국도로학회 2020 한국도로학회논문집 Vol.22 No.1

        PURPOSES: Nitrogen oxide (NOx) is a particulate matter precursor, which is a harmful gas contributing to air pollution and causes acid rain. The approaching methods for NOx removal from the air are the focus of numerous researchers worldwide. Titanium dioxide (TiO2) and activated carbon are particularly useful materials for NOx removal. The mechanism of NOx elimination by using TiO2 requires sunlight for a photocatalytic reaction, while activated carbon absorbs the NOx particle into the pore itself after contact with the atmosphere. The mixing method of these two materials with concrete, coating, and penetration methods on the surface is an alternative method for NOx removal. However, this mixing method is not as efficient as the coating and penetration methods because the TiO2 and the activated carbon inside the concrete cannot come in contact with sunlight and air, respectively. Hence, the coating and penetration methods may be effective solutions for directly exposing these materials to the environment. However, the coating method requires surface pretreatment, such as milling, prior to securing contact, and this may not satisfy economic considerations. Therefore, this study aims to apply TiO2 and activated carbon on the concrete surface by using the penetration method. METHODS : Surface penetrants, namely silane siloxane and silicate, were used in this study. Photocatalyst TiO2 and adsorbent activated carbons were selected. TiO2 was formed by the crystal structures of anatase and rutile, while the activated carbons were plant- and coal-type materials. Each penetrant was mixed with each particulate matter reductant. The mixtures were sprayed on the concrete surface using concentration ratios of 8:2 and 9:1. A scanning electron microscopy with energy dispersive X-ray equipment was employed to measure the penetration depth of each specimen. The optimum concentration ratio was selected based on the penetration depth. RESULTS: TiO2 and activated carbon were penetrated within 1 mm from the concrete surface. This TiO2 distribution was acceptable because TiO2 and activated carbon locate to where they can directly come in contact with sunlight and air pollutant, respectively. Infiltration to the concrete surface was easily achieved because the concrete voids were bigger than the nanosized TiO2 and microsized activated carbon. The amount of penetration for each particulate matter reductant was measured from the concrete surface to a certain depth. CONCLUSIONS : The mass ratio on the surface can be predicted from the mass ratio of the particulate matter reductant measurement distributed through the penetration depth. The optimum mass ratio was also presented. Moreover, the mixtures of TiO2 with silane siloxane and activated carbon with silicate were recommended with an 8:2 concentration ratio.

      • KCI등재

        미세먼지 전구체 저감 소재를 표면 침투한 콘크리트 부재의 질소산화물(NOx) 제거효율 평가

        안희락,김영규,이승우 한국도로학회 2020 한국도로학회논문집 Vol.22 No.5

        PURPOSES : NOx is a particle matter precursor that is harmful to humans. Various methods of removing NOx from the air have been developed. TiO2 and activated carbon are particularly useful materials for removing NOx, and the method is known as particulate matter precursor reduction. The removal of NOx using TiO2 requires sunlight for the photocatalytic reaction, whereas activated carbon absorbs NOx particles into its pores after contact with the atmosphere. The purpose of this study is to evaluate the NOx removal efficiency of TiO2 and activated carbon applied to concrete surfaces using the penetration method. METHODS : Surface penetration agents, such as silane-siloxane and silicate, were used. Photocatalyst TiO2 and adsorbent activated carbons were selected as the materials for NOx removal. TiO2 used in this study was formed by crystal structures of anatase and rutile, and plant-type and coal-type materials were used for the activated carbon. Each surface penetration agent was mixed with each particulate matter sealer at a concentration ratio of 8:2, and the mixtures were sprayed onto the surface. The NOx removal efficiency was evaluated using NOx removal efficiency equipment fabricated in compliance with the ISO 22197-1 standard. RESULTS : Anatase TiO2 showed a maximum NOx removal efficiency of 48% when 500 g/m² was applied. However, 500 g/m² of rutile TiO2 showed a NOx removal efficiency of up to 10%. When 700 g/m² of coal-based activated carbon and plant-based activated carbon was used, NOx removal efficiencies of up to 11% and 14%, respectively, were obtained. CONCLUSIONS : Rutile TiO2, a coal-based activated carbon, and plant-based activated carbon have lower NOx removal efficiencies than anatase TiO2. A lower amount of anatase TiO2 (500 g/m²), compared to the other spraying volumes, yielded the most significant NOx removal efficiency under optimal conditions. Therefore, it is recommended that 500 g/m² of anatase TiO2 should be sprayed onto concrete structures to improve the economic and long-term performance of these structures.

      • KCI등재

        TiO2 콘크리트의 표면열화에 따른 질소산화물(NOx) 제거효율 평가

        안희락,김영규,이승우 한국도로학회 2022 한국도로학회논문집 Vol.24 No.2

        PURPOSES : Recently, air pollution caused by particulate matter has been worsening. Among the substances generating particulate matter, NOx is the main precursor of particulate matter and is widely distributed in areas with a high volume of traffic. TiO2 has been used as a material for removing NOx through a chemical reaction as a photocatalyst. In this context, the reduction of NOx through TiO2 concrete is proposed. However, the research on the surface deterioration on the performance of TiO2 concrete is not documented yet. Therefore, the objective of this study was to evaluate the long-term durability and NOx removal efficiency of TiO2 concrete by considering the concrete surface deterioration. METHODS : Freezing–thawing resistance test (KS F 2456) and scaling test (ASTM C 672) were performed to investigate the variation in the TiO2 penetration distribution and NOx removal efficiency of TiO2 concrete corresponding to surface deterioration. The long-term durability of TiO2 concrete was evaluated through an environmental resistance test and changes in TiO2 penetration depth and distribution characteristics. In addition, the NOx removal efficiency of TiO2 concrete was evaluated as surface deterioration occurs. RESULTS : As a result of the freeze–thawing resistance test, a relative dynamic elastic modulus of more than 80 % was detected. In addition, a TiO2 penetration depth of 0.3 mm, NOx removal efficiency of 11.2 %, and a 30 % of TiO2 surface prediction mass ratio were achieved after 300 cycles. As a result of visual observation of the scaling test, “0, no scaling” was secured. After 50 cycles of scaling test, the TiO2 penetration depth, NOx removal efficiency, and TiO2 surface prediction mass ratio were 0.3 mm, 36.3 %, and 63 %, respectively. Through the results of the environmental resistance test, the excellent long-term durability and NOx removal efficiency of TiO2 concrete were confirmed. CONCLUSIONS : As a result of the experiment, long-term durability and NOx removal efficiency of TiO2 concrete were secured. The application of TiO2 concrete can be a good alternative with long-term performance and durability.

      • KCI등재

        콘크리트 포장 블로우업 모델의 이해 및 한계점

        안희락,김영규,이승우 한국도로학회 2023 한국도로학회논문집 Vol.25 No.3

        PURPOSES : During the summer of 2018, a heat wave (temperatures > 33°C) lasted for more than 30 days, causing blow-ups at eight different locations in South Korea. The blow-up phenomenon occurred when the internal temperature of the concrete slab increased. Simultaneously, as the concrete slab expands excessively, the length of the end of the slab increases, thus resulting in a lateral compressive force; when the slab cannot withstand this force, it rises or breaks. Blow-up is caused by a variety of factors, including increased temperature and humidity, accumulation of incompressible substances inside discontinuous surfaces, alkali–silica reactions, and aging of the concrete pavement. Several researchers have presented models to forecast blow-ups, such as the A. D. Kerr and G. Yang models, which have been applied to explain the blow-up phenomenon. However, this model has some limitations. This paper discusses a method to overcome these limitations. METHODS : Buckling, the most important theory describing the blow-up phenomenon, was reviewed, and the buckling principle was confirmed. Subsequently, the input variables of the Kerr and Yang models and the mechanism for predicting the occurrence of blow-ups were identified. The PGBA program was used to confirm the lifetime of the expansion joint and the blow-up occurrence time based on the expansion joint spacing to review the limitations of the two studied models. RESULTS : The Kerr and Yang models did not consider variables such as the expansion joint spacing or length of the integrated adjacent slab. In other words, it is necessary to reconsider the appropriateness of blow-up time predictions in relation to changes in expansion joint spacing and slab length. The expansion joint lifetime and blow-up occurrence time were predicted using the PGBA program. It was confirmed that as the expansion joint spacing increases, the expansion joint lifetime decreases. However, the blow-up occurrence time was shown to be the same (equal to 59 years), which is a limitation of the Kerr and Yang models used in the PGBA program. This resulted in a limitation in which variables for the expansion joint spacing cannot be used. CONCLUSIONS : Through blow-up simulation experiments and actual field data, an appropriate slab length should be determined, and a blow-up model should be developed based on the slab length. If a blow-up prediction based on concrete slab length and a blow-up model based on are developed, the blow-up prevention technology will be applied to the appropriate blow-up time and location to avoid traffic accidents and reduce human and property damage.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼