http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
불소가 첨가된 비정질 탄소 박막을 이용한 수직 액정 배향 효과
안한진 ( Han Jin Ahn ),김경찬 ( Kyung Chan Kim ),김종복 ( Jong Bok Kim ),황병하 ( Byoung Har Hwang ),백홍구 ( Hong Koo Baik ),이세종 ( Se Jong Lee ) 대한금속재료학회 ( 구 대한금속학회 ) 2005 ELECTRONIC MATERIALS LETTERS Vol.1 No.1
Homeotropic orientations of nematic liquid crystal (NLC) are investigated on fluorinated diamond-like carbon (FDLC) films that are exposed to an Ar ion-beam. These novel investigations result in the realization of a completely dry processing technique for both the thin film deposition and alignment steps. FDLC films are selected on the basis of the characteristics of the homeotropic alignment layer with regard to the relationship between surface tension and LC orientation. Extreme hydrophobic property from the CFx bonding on the surface contributed largely to the uniform vertical LC alignment. Ion beam process which was treated after FDLC deposition generates suitable pretilt angle tram the surface normal. Selected pretilt angles in the range of 71~90˚could be obtained with ion beam irradiation. These pretilt angles had sensitive dependences on the thin film composition and the angle of ion-beam irradiation.
안신영 ( Shin Young Ahn ),박재윤 ( Jae Yoon Park ),이성우 ( Seong Woo Lee ),정종철 ( Jong Cheol Jeong ),정지용 ( Ji Yong Jung ),오국환 ( Kook Hwan Oh ),김연수 ( Yon Su Kim ),안규리 ( Cu Rie Ahn ),한진석 ( Jin Suk Han ),김성권 ( Su 대한신장학회 2010 Kidney Research and Clinical Practice Vol.29 No.2
Purpose: C1q nephropathy (C1qN) is a rare glomerulonephritis characterized by mesangial deposits, predominantly C1q, without the evidence of systemic lupus erythematosus (SLE). It showed various clinical courses, however, the clinicopathologic features of C1qN have not been well defined as yet. Methods: We retrospectively reviewed the clinicopathologic features of 11 patients (0.8%) diagnosed as C1qN among 1,403 patients aged 18 years who had undergone renal biopsy due to primary glo ≥-merular disease from Jan. 2000 to Jan. 2009. Diagnostic criteria of C1qN were as follows; 1) the presence of dominant or co-dominant immunofluorescence staining for C1q in the mesangium, 2) corresponding mesangial dense deposit by electron microscopy, and 3) lack of clinical evidence of SLE. Results: The male-to-female ratio was 6:5 and their mean age was 41.1±22.6 yrs (range, 19-69 yrs). Eight patients presented with urinary abnormalities and three with nephrotic syndrome. At the time of biopsy, three patients had hypertension. The mean value of 24-hour urine protein was 4.4±5.5g/day (range, 0.5-18.5g/day). On light microscopy, normal glomerular architecture (4/11) and segmental sclerosis (7/11) were observed. Complete or partial remission was achieved in six of the seven patients treated with immunosuppressive agents (steroid and/or immunosuppressants). Among these patients, two using steroid monotherapy had relapsed. The mean follow-up duration was 14±11 months (range, 2-31 months) and renal function deterioration was observed in three patients. Conclusion: C1qN showed various clinical manifestations and prognosis. Therefore, additional studies are needed to fully define the clinicopathologic features.
무기 박막을 이용한 이온빔 배향 FFS 셀의 전기광학특성에 관한 연구
황정연,박창준,정연학,김경찬,안한진,백홍구,서대식,Hwang, Jeoung-Yeon,Park, Chang-Joon,Jeong, Youn-Hak,Kim, Kyung-Chan,Ahn, Han-Jin,Baik, Hong-Koo,Seo, Dae-Shik 한국전기전자재료학회 2004 전기전자재료학회논문지 Vol.17 No.10
In this paper, we intend to make fringe-field switching (FFS) mode cell by the ion beam (IB) alignment method on the a-C:H thin film, to analyze electro-optical characteristics in this cell. We studied on the suitable inorganic thin film for fringe-field switching (FFS) cell and the aligning capabilities of nematic liquid crystal (NLC) using the alignment material of a-C:H thin film as working gas at 30 W rf bias condition. A high pretilt angle of about 5 $^{\circ}C$ by ion beam (IB) exposure on the a-C:H thin film surface was measured. Consequently, the high pretilt angle and the good thermal stability of LC alignment by the IB alignment method on the a-C:H thin film surface as working gas at 30 W rf bias condition can be achieved. An excellent voltage-transmittance (V -T) and response time curve of the IE-aligned FFS-LCD was observed with oblique IB exposure on the a-C:H thin films. Also, AC V-T hysteresis characteristics of the IB-aligned FFS-LCD with IE exposure on the a-C:H thin films is almost the same as that of the rubbing-aligned FFS cell on a polyimide (PI) surface.