김태형(T.H. Kim),안영주(Y.J. An),안진우(J.W. Ahn) 전력전자학회 2003 전력전자학술대회 논문집 Vol.2003 No.7(2)
<br/> In a switched reluctance motor drive, it is important to synchronize the stator phase excitation with the rotor position, because the position of rotor is an essential information In the high-speed region, switching angles are fluctuated back and forth out of the preset value, which is caused by the sampling period of the microprocessor.<br/> In this paper, a low cost analog encoder suitable for practical applications is proposed The validity of the proposed analog encoder with a proper logic controller is verified from the experiments<br/>
α-레벨집합 분해에 의한 서보시스템용 퍼지추론과 하드웨어
홍순일(S.I.Hong),안영주(Y.J.An),김정환(J.H.Kim),이요섭(Y.S.Lee) 전력전자학회 2000 전력전자학술대회 논문집 Vol.2000 No.11
In this paper, we propose a calculation method for fuzzy control based on quantized α-cut decompoSItion<br/> of fuzzy sets, This method is easy to be implemented in analog hardware. The effect of quantization levels on defuzzified fuzzy inference result is investigated. A few quantization levels are sufficient for fuzzy control. The hardware implementation of this calculation method and the defuzzification by gravity center method by PWM are also presented.
송현수(H.S. Song),안영주(Y.J. An),안진우(J.W. Ahn) 전력전자학회 2003 전력전자학술대회 논문집 Vol.2003 No.7(2)
The environmental problem and the dram of petroleum fuel resources has been became the center of public interest. So the electric drive attracts public attention The vehicles for indoor works should not pollute air Therefore it is also useful that applying electric drive to such an appliance<br/> An 12[kw] SRM for a pallet truck drive is developed and tested The drive system has to operate with low voltage and high current. The small size, robustness, high efficiency make it possible to replace with DC motor<br/> Test results show that pallet truck W1th SRM has better characteristics than that of the DC motor performance.<br/>
안영주,김남호,이형기 한국산업안전학회 1997 한국안전학회지 Vol.12 No.1
There are two kinds of ground fault diagonosis system(GFD), which are for AC and DC power line. The ground fault current of a DC power line is, first, analyzed for a description of a GFD system for DC power line and then the construction method of the GFD system, which could be processed and analyzed a ground fault current, are explained. Main functions of the system are that the detected ground fault current could be converted to the line insulation resistance by a program and saved in the system memory continuously. Finally a DC power line insulation safety could be decide by a change of the saved insulation resistance for a given time. This system can detect the ground fault resistance to 100KΩ
송전선로의 점퍼선 안전성 향상을 위한 횡진각 계산에 관한 연구
안영주,신춘식,변기식 한국산업안전학회 1997 한국안전학회지 Vol.12 No.1
As jumpers for overhead transmission lines increase in size, it is necessary to take into the characteristics of jumper swaying space in order to determine jumper reinforcements adequately. From the theory of a structure made of beams, formulas for the sideway swaying of overhead transmission lines due to wind are modeled. And also natural frequency of the vibrated jumper is estimated to check the system resonance. The theoretical results can be led good suggestions to improve the economy and reliability of jumper structure.
안영주,신춘식,변기식 한국산업안전학회 1999 한국안전학회지 Vol.14 No.1
Local heating transportation pipe has sensor and return lines to detect water-leakage. There are impulse and resistance comparison measurement types for a water-leakage detection. The impulse type shows large detection error within a measurement range. Since the resistance comparison type can find a comparative accurate single water-leakage point in the measurement range of heating pipe, it has been used to detect water-leakages these days. However if the multi water-leakages are happened in the measurement range of transportation pipe, the resistance comparison type shows a detection error point by the parallel resistance between a detection sensor line and ground. But the detection error will be minimized by the divided transportation pipe loops. In this research, it suggests the design of remote controlled detection system which can divide a large pipe loop and a possible single water-leakage measurement process in each divided loops.