유도 전동기에서 발생한 펄스 토크에 의한 회전축계의 비틀림진동과 대책
이돈출(Donchool Lee),버광다오(QuangDao Voung),남택근(Taekkun Nam) 한국소음진동공학회 2015 한국소음진동공학회 학술대회논문집 Vol.2015 No.4
Recently, commercial ships and other specialized vessels with electric propulsion system employ induction motor as its prime mover. The wide application of electrical motors also includes being the main drive system in most industrial machineries. However, during its start-up, shutdown, and brake switch operation, excessive torque variation are generated. As such, flexible coupling are installed in order to reduce the transmitted torque fluctuation to the driven side. In this paper, the pulse torque generated by an induction motor was analyzed theoretically and through measurement of torsional vibration. Induction motor with inverter on marine propulsion system and industrial compressor were used as experimental subjects. The study confirmed that pulse torque are generated regardless of motor speed and interpreted as a vibration source of the whole system. Results presented herein can be adopted as the basis in future amendment of inspection classifying body regulations.