http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
박승호,정재희,이승복,배귀남,지현석,조소혜 한국입자에어로졸학회 2011 Particle and Aerosol Research Vol.7 No.4
The aerosol nanoparticles are suspected to be exposed to workers in nanomaterial manufacturing facilities. However, the exposure assessment method has not been established. One of important issues is to characterize background level of nanoparticles in workplaces. In this study, intensive aerosol measurements were made at a TiO_2 manufacturing laboratory for five consecutive days in May of 2010. The TiO_2 nanoparticles were manufactured by the thermal-condensation process in a heated tube furnace. The particle number size distribution was measured using a scanning mobility particle sizer every 5 min, in order to detect particles ranging from 14.5 to 664 nm in diameter. Total particle number concentration shows a severe diurnal variation irrespective of manufacturing process, which was governed by nanoparticles smaller than 50 nm in diameter. During the background monitoring periods, significant peak concentrations were observed between 2 p.m. and 3 p.m. due to the infiltration of secondary aerosol particles formed by photochemical smog. Although significant increase in nanoparticle concentration was also observed during the manufacturing process twice among three times, these particle peak concentrations were lower than those observed during the background measurement. It is suggested that the investigation of background particle contamination is needed prior to conducting main exposure assessment in nanomaterial manufacturing workplaces or laboratories.
고화질 PDP 구현을 위한 신호 및 영상 처리 기술 동향
박승호,김춘우,Park, Seung-Ho,Kim, Chun-U 한국정보디스플레이학회 2002 인포메이션 디스플레이 Vol.3 No.6
PDP에 표시되는 영상의 화질은 PDP 구매 결정에 영향을 미치는 가장 중요한 요소들 중의 하나이다. PDP에서의 화질은 주로 PDP 구동방식, 셀의 구조, 사용되는 방전가스 및 형광체의 특성, 표시 가능 화소수 등과 같은 PDP 구성 요소들에 의해 좌우된다. 이와 같은 PDP의 구성 요소들을 개선함으로서 화질을 향상시킬 수 있다. 하지만, 이미 구성 요소들이 결정되어져 있는 경우 신호 및 영상 처리 방법들을 적용함으로서 PDP에서의 화질을 개선시킬 수 있다. 본 소고에서는 PDP에서의 고화질 구현을 위한 신호 및 영상처리 기술들을 소개하기로 한다.
박승호 경북대학교 법학연구원 2012 법학논고 Vol.0 No.38
Spontaneous assembly and urgent assembly can't observe the advance notice article. The advance notice article violates the principle of proportionality and the void-for-vagueness doctrine because it doesn't provide for the exception of notice obligation . It is against the principle of proportionality for the chief of a police station concerned to order the assembly without advance notice to disperse, notwithstanding the less restrictive alternative has not been exhausted. It is infringing on the freedom of assembly to punish someone on the ground of his having hosted an assembly without advance notice. It is also against the principle of proportionality to punish him because of nonperformance of cooperation obligation in administrative procedure. The article prohibiting violent assembly violates the void-for-vagueness doctrine because it doesn't prescribe for the presence of danger. Advance notice combined with prohibition notice substantially functions as licensing and permit system. 집회의 자유에 대한 제한으로서 수리를 요하지 않는 신고로서의 사전신고제 자체는 헌법적으로 허용된다. 우발적 집회와 긴급집회는 사전신고조항을 준수할 수 없다. 신고의무의 예외를 규정하지 않고 있는 집시법 사전신고조항은 비례의 원칙과 명확성원칙에 반한다. 집회의 금지와 해산은 집회의 자유를 보다 적게 제한하는 다른 수단을 모두 소진한 후에 사용될 수 있는 최종적인 수단이다. 따라서 미신고집회에 대하여 곧바로 해산명령을 내리는 것은 비례의 원칙에 반한다. 미신고집회라는 이유로 형사처벌하는 것은 잠재적인 집회주최자로 하여금 형사처벌의 두려움 때문에 집회의 주최를 포기하게 만들 수 있으므로 집회의 자유를 축소(침해)하는 것이며, 행정절차상 협력의무의 불이행을 이유로 형벌을 가하는 것은 비례의 원칙에 반한다. 폭력집회금지규정은 명백하고 현존하는 위험의 원칙에 비추어 현존성이 규정되어 있지 않아 명확성원칙에 반한다. 사전신고는 금지통고와 결합하여 실질적으로 허가제 기능을 수행한다. 요컨대 신고가 불가능하거나 신고기간을 준수할 수 없는 집회에 대해서조차 예외 없이 사전신고의무를 부과하고, 일정한 경우 집회금지통고가 가능하며, 미신고집회에 대해 해산을 명할 수 있고, 이들을 위반한 경우 형사처벌하도록 규정하고 있는 집시법상 사전신고제도는 허가제이며 비례의 원칙과 명확성원칙에 반한다.
양성 조영제를 사용한 복촬영술(Positive Contrast Peritoneography)에 대한 임상적 관찰
박승호 대한영상의학회 1975 대한영상의학회지 Vol.11 No.2
Positive contrast peritoneography is a reasonably safe and quite accurate method, identifying patent vaginal processes, hernias, communication hydroceles, and undescened testes, etc., The examination is simple to perform and interpret and can also be used to evaluate diaphragmatic abnormalities and spleen, and some intraperitoneal masses. Positive contrast peritoneography were performed in 26 cases at Busan National University Hospital during the period from October 1973 to August 1974. The results were as follows: 1. Successful peritoneograms are obtained in 24 cases among the total of 26 cases. 20 out of 24 cases were confirmed by operation. 3. Among the 20 cases operated 11 cases showed unilateral open saces, and 7 cases showed bilateral open sacs. 4. The accuracy of these peritoneography was 89%, however, the accuracy of the physical examination was 67%.