박건복,김염기 공주대학교 생산기술연구소 2000 論文集 Vol.8 No.-
Structures of power plant are plant are moving during the operation mainly due to the thermal expansion. If the structures move abnormally, the structures might be damaged. Therefore the monitoring of the structure is needed to avoid the unexpected behavior. In this study, a monitoring system which can measure the three-dimensional movement of structure was developed, and applied to the boiler structure of fossil power plant. As the result, the boiler structure turned out to move down about 230mm. However, although replacing the burner system or the condition of combustion, the variation of movement in the bottom of boiler was relatively small.