http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
시간지연을 고려한 영구자석 동기전동기 전류제어기의 이산시간 안정도 해석
김무현(M.H. Kim),임정규(J.G. Lim),정세교(S.K. Chung) 전력전자학회 2009 전력전자학술대회 논문집 Vol.2009 No.1
This paper presents a stability analysis for the digital current control system of PM synchronous motor drives with a fast dynamic response. The current control loop is modeled in a discrete-time domain and the closed loop stability of the discrete-time synchronous PI regulator is analyzed considering the sensor time delay. the simulation results are provided to verify the theoretic analysis.
영구자석 동기전동기를 위한 디지털 PI 전류제어기의 제어특성
김무현(M.H. Kim),임정규(J.G. Lim),정세교(S.K. Chung) 전력전자학회 2009 전력전자학술대회 논문집 Vol.2009 No.2
The synchronous PI current controller has been widely used for the high performance PM synchronous drives and generally implemented using a digital signal processor. This paper describes the control characteristics of the digital PI current controller for PM synchronous drives. The stability of the current control system considering the sampling time is investigated and the effects of the mismatched decoupling terms in the discrete-time domain are also discussed. The simulation results are provided to verify the theoretic results.
The Performance of a Horizontal Flexible Membrane Breakwater in Waves
조일형,홍석원,김무현,Cho I.H.,Hong S.W.,Kim M.H. 한국해양환경·에너지학회 1998 한국해양환경·에너지학회지 Vol.1 No.2
본 연구에서는 수면 밑 일정한 깊이에 잠긴 유연한 천이 파도중 수평으로 놓여 있을 때 유연막과 파도의 상호작용 문제를 살펴보았다. 파도와 유연막의 상호작용을 고려하기 위하여 선형 유탄성 이론을 사용하였다. 계산 예로 유연막의 형태, 잠긴 깊이 그리고 유연막에 걸리는 초기 장력을 변화시키면서 반사율과 투과율 그리고 유연막의 변형을 살펴보았다. 또한 Texas A&M 대학의 2차원 수조에서 모형실험을 수행하여 실험결과와 해석해를 비교하였다. 실험결과와 해석결과는 정성적으로 잘 일치하고 있음을 확인하였다. 개발된 설계 프로그램을 이용하여 설치 해역의 파랑 특성에 적합한 최적의 유연막 방파제를 설계, 제작할 수 있으리라 사료된다. The interaction of monochromatic incident waves with a horizontal flexible membrane is investigated in the context of two-dimensional linear hydro-elastic theory. First, analytic diffraction and radiation solutions for a submerged impermeable horizontal membrane are obtained. Second, the theoretical prediction was compared with a series of experiments conducted in a two-dimensional wave tank at Texas A&M University. The measured reflection and transmission coefficients reasonably follow the trend of predicted values. Using the developed computer program, the performance of surface-mounted or submerged horizontal membrane wave barriers is tested with various system parameters and wave characteristics. It is found that the properly designed horizontal flexible membrane can be an effective wave barrier.
강병극(B. K. Kang),김무현(M. H. Kim),임정규(J. G. Lim),정세교(S. K. Chung) 전력전자학회 2008 전력전자학술대회 논문집 Vol.- No.-
A novel lossless current sensing technique for a synchronous buck converter is presented. The inductor DCR method is generally used as a low cost and lossless current sensing technique of DC/DC converters. It is however difficult to obtain the accurate current value for the conventional DCR method because the inductor resistance varies depending on the operating frequency. In order to overcome this problem, an improved current sensing technique is proposed, which has the separated DC and AC sensing circuits. The concept and operation of the proposed method are explained and the experimental results are provided to show its effectiveness.
태양열입사량, 환기량 및 종횡비의 변화에 따른 환기식 3중 집열창시스템의 열전달특성
김무현,정의준,오창용 울산대학교 1998 공학연구논문집 Vol.29 No.2
동절기 실내 난방시 별도의 환기열손실을 고려할 필요가 없는 환기식 3중 집열창에 대하여 열전달특성을 수치해석적으로 연구하였다. 주요변수로 환기량을 나타내는 Re수, 종횡비 그리고 태양열입사량등을 고려하였다. 연구결과 외기열손실을 최소화하기 위해서는 종횡비가 낮을수록 더 많은 환기량이 요구되었다. 밀폐식3중창과 비교하여 볼 때 환기식3중창은 입사량 10W/m², 종횡비 0.05, Re수 600인 경우 약 85%까지 외기열손실이 감소되는 것으로 나타났으며 태양열입사량이 작을수록 외기열손실 감소효과가 커진다는 결과를 얻었다. 또한 환기식 집열창의 설계시 종횡비는 0.05내외가 적절하며 환기량[Re수]은 600 이내의 값을 택하는 것이 바람직한 것으로 나타났다. The heat transfer characteristics of a triple glazed airflow window system is studied numerically by a finite volume method. Attention is paid to the effects of solar energy power, ventilation rate and window geometry on the flow field and thermal performance. As a result of the comparison between airflow window and enclosed window, the ambient heat loss of airflow window is reduced remarkably. It is suggested that in the design of airflow window system aspect ratio, H/W≒0.05 and Re ≤600 are appropriate.