RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        수종의 영구 탄성 이장재와 의치상용 레진간의 인장 결합 강도

        김래규,정문규,임순호,Kim, Lae-Gyu,Chung, Moon-Kyu,Yim, Soon-Ho 대한치과보철학회 1999 대한치과보철학회지 Vol.37 No.2

        For many years permanent soft denture liners has been widely used in dental practice directly or indirectly because of its function in absorbing and distributing the impact force. However, it reveals problems such as lack of permanency and decreased bond strength in long term use. The purpose of this study is to measure the bond strength and failure between denture base resin and several permanent liners. Lucitone 199 was used as denture base resin with soft acrylic liners (Triad, Tokuso Rebase) and silicone elastomers (Tokuyama, Ufi Gel C) bonded to measure the tensile strength before and after thermocycling. The thermocycling was done in 2000 cycles at $5^{\circ}C,\;26^{\circ}C\;and\;55^{\circ}C$ and the measured tensile strength values before and after thermocycling were compared. The mode of failure was investigated in the separated specimens. The results are as follows. 1. As to tensile strength, the strongest material is Tokuso Rebase followed by Triad, Tokuyama, Ufi Gel C in before thermocycling and the order of Triad, Tokuso Rebase, Tokuyama, Ufi Gel C in after thermocycling state. There was significant difference between the values of Triad, Tokuso Rebase and Tokuyama, Ufi Gel C(p<0.05). 2. As to degree of displacement, Ufi Gel C showed most displacement with or without thermo-cycling treatment and also the difference was significant with the other materials(p<0.05). 3. As to comparisons before and after thermocycling, Tokuso Rebase and Tokuyama showed significant difference in bond strength, whereas Triad and Tokuso Rebase showed significant difference in the degree of displacement(p<0.05). 4. In debonded specimens, Triad and Ufi Gel C showed adhesion failure and Tokuyama showed cohesion failure. Both failures were observed in Tokuso Rebase with adhesion failure up to 70%. The results of this study showed that degree of bond strength between permanent soft denture liner and denture base resin were variable. There was a significant difference between soft acrylics and silicone elastomers with regard to bond strength. Further research in improving bond strength of widely used silicone elastomers and in developing the method of measuring bond strength between denture base resin and the lining materials is needed.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼