http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이덕보(D. B. Lee),강수근(S. K. Kang),김정현(K. J. Kim),김주형(J. H. Kim),전영찬(Y. C. Jeon) 대한기계학회 2005 대한기계학회 춘추학술대회 Vol.2005 No.11
Surface design of dental post materials improves adhesive force between a post and a root dentin and has significant influences on the reliability in endodontically treated tooth. To investigate relationship between the design of shape and the strength of material, dental posts made of nickelchromium alloy were prepared. Three-point bending test was performed using the post material, which is utilized actually in teeth treatment. The fracture surface of specimen was examined by Scanning Electron Microscope(SEM) through failure analysis. Based on experimental results, the numerical analysis was simulated using ABAQUS, one of commercial software. The bending strength of modified post material model is higher than that of custom post material model. The modified design of the dental post material was also proposed.
Water drop 가속시험에 의한 이온 마이그레이션 발생 메커니즘
이덕보(D. B. LEE),강수근(S. K. Kang),장석원(S. W. Chang),유동수(D. S. Ryu) 한국동력기계공학회 2004 한국동력기계공학회 학술대회 논문집 Vol.- No.-
In evaluation of electronic reliability on the PCB(Print Circuit Borad), electrochemical migration is one of main test objects. The phenomenon of electrochemical migration occurs in the environment of the hight humidity and the hight temperature under bias through a continuous aqueous electrolyte. In this paper, the generating mechanism of electrochemical migration is investigated by using water drop acceleration test under various waters. The waters used in the water drop test are city water, distilled water and ionic water. It found that the generated velocity of electrochemical migration depended on electrolyte quantity which included in the various waters.
선박용 calorifier의 고장모드에 대한 가속수명시험
이덕보(D. B. LEE),김정현(J. H. KIM),강수근(S. K. KANG),강영복(Y. B. KANG),김형삼(H. S. KIM) 한국동력기계공학회 2005 한국동력기계공학회 학술대회 논문집 Vol.- No.-
Basic function of calorifier system is to supply warm water to the vessel. The heater used in the calorifier system plays a very important role in its reliability. The failure mechanism of heater are compared with accelerated life test. The main cause of failed heater is pitting corrosion occurred between the surface of heater and spacer. To prevent the corrosion failure from heater, material of spacer replaces metal(SUS 304) with polymer(Acryl). The life of redesigned heater can guarantee 2.47years of B10 life under the worst condition.
이덕보(D. B. Lee),김정현(J. H. Kim),강수근(S. K. Kang),김상도(S. D. Kim),장석원(S. W. Chang),임재훈(J. H. Lim),유동수(D. S. Ryu) 대한기계학회 2005 대한기계학회 춘추학술대회 Vol.2005 No.5
In evaluation of electronic reliability on the PCB(Printed Circuit Board),electrochemical migration is one of main test objects. The phenomenon of electrochemical migration occurs in the environment of the high humidity and the high temperature under bias through a continuous aqueous electrolyte. In this paper, the generating mechanism of electrochemical migration is investigated by using water drop acceleration test under various waters. The waters used in the water drop test are city water, distilled water and ionic water. It found that the generated velocity of electrochemical migration depended on the temperature of water and the electrolyte quantity which included in the various waters.
이덕보(D. B. Lee),김정현(J. H. Kim),강수근(S. K. Kang),조영진(Y. J. Cho),장석원(S. W. Chang),임재훈(J. H. Lim),유동수(D. S. Ryu) 대한기계학회 2005 대한기계학회 춘추학술대회 Vol.2005 No.5
The opening test of a filament is very important for the reliability of fluorescent lamps. Failure mechanisms of filament in fluorescent lamps are investigated by the filament accelerated stress test and voltage accelerated stress test. The characteristics of the accelerated test data are also compared with those of field data. The failure sites of filament in fluorescent lamp were occurred at the middle part of filament due to radiant heat and the edge part of filament due to torsional stress caused by thermal stress. It found that the life time of fluorescent lamp was effected by the cooling time and the structure of filament.