RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 단열배관의 온라인 두께측정시스템 개발

        장지훈,김병주,조경식,김기동,Jang, Ji-Hun,Kim, Byeong-Ju,Jo, Gyeong-Sik,Kim, Gi-Dong 한국기계연구원 2002 硏究論文集 Vol.32 No.-

        The intensity of x-ray or gamma-ray is attenuated according to density and thickness of the transmitted medium. In this study, by using this principle, on-line real-time radiometric system was developed using a 128 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses a Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer. This system collects and analyses the data from the detector array in real-time. The maximum measurable length of pipe is 120cm/mm. in the case of 1mm scanning interval.

      • Numerical Analysis of Turbulent Combustion and Emissions in an HRSG System

        장지훈,한가람,박호영,이욱륜,허강열,Jang, Jihoon,Han, Karam,Park, Hoyoung,Lee, Wook-Ryun,Huh, Kangyul Korea Electric Power Corporation 2019 KEPCO Journal on electric power and energy Vol.5 No.2

        The combined cycle plant is an integration of gas turbine and steam turbine, combining the advantages of both cycles. It recovers the heat energy from gas turbine exhaust to use it to generate steam. The heat recovery steam generator plays a crucial role in combined cycle plants, providing the link between the gas turbine and the steam turbine. Simulation of the performance of the HRSG is required to study its effect on the entire cycle and system. Computational fluid dynamics has potential to become a useful to validate the performance of the HRSG. In this study a solver has been implemented in the open source code, OpenFOAM, for combustion simulation in the heat recovery steam generator. The solver is based on the steady laminar flamelet model to simulate detailed chemical reaction mechanism. Thereafter, the solver is used for simulation of HRSG system. Three cases with varying fuel injections and gas turbine exhaust gas flow rates were simulated and the results were compared with measurements at the system outlet. Predicted temperature and emissions and those from measurements showed the same trend and in quantitative agreement.

      • KCI등재

        임플란트 고정체의 의원성 동요 후 골 유착 반응에 관한 연구

        장지훈,조진현,이청희,Jang, Ji-Hoon,Cho, Jin-Hyun,Lee, Cheong-Hee 대한치과보철학회 2010 대한치과보철학회지 Vol.48 No.3

        연구 목적: 본 연구의 목적은 골 유착된 임플란트에 인위적 비틀림을 가한 후 골 유착이 다시 일어나는지, 혹은 일어나지 않는지, 일어난다면 이전의 골유착보다 강화되는지, 약화되는지에 대해 알아보기 위함이다. 연구 재료 및 방법:상업적으로 순수한 티타늄 (commercial pure titanium 99%)으로 직경 3.75 mm, 길이 4 mm의 표면처리 없는 실험용 임플란트를 제작하였다. 3.0 kg이상의 뉴질랜드산 흰색 암컷 토끼 7마리의 좌우 경골에 제작한 임플란트를 2개씩 식립 후, 6주의 골유착 유도 기간 부여 후 비틀림 제거력을 측정한 경우를 I군으로, 다시 임플란트 고정체를 재위치시키고 봉합하여 4주간의 치유기간을 더 두고 측정한 경우를 II군으로 분류하였다. 광학현미경을 이용한 조직 형태학적 분석을 위하여, 1차 비틀림 제거력 측정 직후 1마리의 토끼를 희생시키고, 2차 비틀림 제거력 측정 직후 2마리의 토끼를 희생시켜 각각 4개, 7개의 시편을 제작하여, 광학현미경 (${\times}20$) 분석에서 골-임플란트 접촉 (Bone-Implant contact, BIC, %)비율과 치밀골 부위에 위치하는 임플란트의 나사산 수를 측정하여 CBa (Bone area in the cortical passage)비율을 측정하였다. 비틀림 제거력과 BIC및 CBa비율에서의 I군과 II군의 통계적 유의성 ($\alpha$=.05)을 평가하였다. 결과: 비틀림 제거력 측정에서 I군은 $10.8{\pm}3.6$ NCm로 측정되었으며, II군은 $20.2{\pm}9.7$ NCm로 측정되었으며, I군보다II군의 비틀림 제거력이 평균 98.1% 증가되었다 (P<.05). 조직 형태학적 분석에서 BIC와 CBa 비율은 I군과 II군 사이에 통계적 유의성을 나타내지 않았고 (P>.05), RT/BIC와 RT/CBa 값은 I군과 II군 사이에 통계적 유의성을 나타냈다 (P<.05). 결론: 임플란트 고정체에 의원성 비틀림 동요가 발생한 경우에 초기 골유착을 얻기 위해 필요로 했던 치유기간보다 짧은 기간 내에 이전보다 견고한 골유착을 얻을 수 있을 것으로 생각된다. Purpose: The purpose of this study was to investigate whether the re-osseointegration of the implants that had mechanical unscrewing possibly occurred or not. Furthermore, if it happened, the degree of re-osseointegration was evaluated by comparing with previous osseointegration. Materials and methods: The smooth implant (commercial pure titanium 99%) specimens, whose diameter and length was 3.75 mm, 4 mm, respectively were produced. Two implants were inserted into each tibia of 7 New Zealand female white rabbits weighing at least 3.0 kg. The torque removal force for each implant after 6 weeks of implants placement was measured and included in group I. The torque removal forces were assessed after the fixtures were re-screwed to original position and the subjects were allowed to have 4 more weeks for healing and included in group II. One rabbit was sacrificed after first measurement and produced 4 slide specimens in group I, and two rabbits were sacrificed after 2nd measurement, 7 slide specimens, in group II for histomorphologic investigations. All slide specimens were assessed based on the proportion of BIC (bone-implant contact) as well as CBa (Bone area in the cortical passage) value produced by counting the screw threads embedded in the compact bones under the optical microscopic analysis (${\times}20$). Statistical analysis was conducted to evaluate the torque removal force, BIC and CBa between group I and II. Results: As for the torque removal force, the result was $10.8{\pm}3.6$ Ncm for group I and $20.2{\pm}9.7$ Ncm for group II. Furthermore, the torque removal force of group II increased by 98.1% in average compared to group I (P<.05). On the other hand, histomorphologic analysis displayed that there was no statistical significance in BIC and CBa values between group I and the group II (P>.05), and RT/BIC and RT/CBa between group I and group II were statistically significant (P<.05). Conclusion: It is possible to obtain more substantial re-osseointegration within shorter periods than the period needed for the initial osseointegration in case of iatrogenically unscrewed implants.

      • KCI등재

        눈물점 마개 사용 후 발생한 합병증의 치험 증례

        장지훈,채종근,김병진,이하범.Ji-Hoon Jang. M.D.. Jong-Keun Chae. M.D.. Byoung-Jin Kim. M.D.. Ha-Bum Lee. M.D. 대한안과학회 2005 대한안과학회지 Vol.46 No.3

        Purpose: To report cases of complications after using punctual plugs with a literature review. Methods: We studied 3 complicated cases after the use of punctual plugs: a 46-year-old female with recurrent mucopurulent discharge, a 42-year-old male with a pinkish mass over the punctum, and a 29-year-old female with recurrent epiphora. Results: The 46-year-old female was diagnosed with canaliculitis caused by actinomyces, the 42-year-old male with chronic pyogenic granuloma, and the 29-year-old female with canalicular obstruction. All 3 cases improved after proper treatments. Conclusions: Complications after the use of punctal plugs are not common but they can be significant. They have to be used carefully after through evaluation and obtained proper informed consents from the patient.

      • KCI등재

        한글 서예의 미학 - 서체미를 중심으로 -

        장지훈,張志熏(Jang, Ji-Hoon) 한국서예학회 2019 서예학연구 Vol.34 No.-

        한글이 창제된 이후, 한글은 서예와 만나면서 풍부하고 다양한 서체와 미감을 형성해왔다. 다만 전통의 한글 서예는 어떠한 형태로 변화해왔는가에 대해서는 인식하기 용이하나, 어떠한 미적 특성을 지니고 있는지에 대한 구체적인 논의는 쉽지 않다. 때문에 한글 서예의 미를 논하기 위해서는 한자 서예의 예술적 특징을 한글 서예에서도 발견하고, 이를 부각시켜야 할 것이다. 이러한 점에 착안하여 한글 서예를 전통의 서법적 관점에서 조명하였다. 먼저 한글 서예의 서체는 대략 고체 ․ 정자체 ․ 흘림체로 분류할 수 있다. 구체적으로 고체는 자형이 좌우대칭과 정사각의 기본적인 틀을 유지하고 있으며, 대체로 단정하고 근엄하여 경건(勁健)의 미를 느낄 수 있다. 획의 굵기 변화는 미세하나, 예서와 해서가 혼합된 남조의 해서풍처럼 기필과 수필의 방필(方筆)이 두드러지며, 대체로 금석의 졸박한 기운이 서려있다. 정자체는 전반적으로 평정한 결구와 안정적인 필세가 특징적이다. 판본의 고체가 필사화 되어가면서 고체에 비해 자형이 세련 되고 필획의 유연함이 두드러지며, 직선적인 필획과 방정한 자형의 정제된 글꼴 속에서도 맑고 담백한 운치를 느끼게 한다. 흘림체는 서간이나 가사 등의 경우, 정자체의 기본 자형을 바탕으로 때로는 거칠고 강렬한 필획을 가미하고 필속을 경쾌하 게 하여 절주(節奏)의 미가 강하다. 반면, 궁서의 경우 곡선적인 섬세한 필획을 부드럽게 연결하여 수려하면서도 정제된 멋이 깃들어 있다. 한글은 한자에 비해 비록 문자의 구조와 글꼴은 단순하지만, 한자 서예가 지닌 다양한 서체의 미학이 한글 서예에도 내재되어 있다. 특히 한글 서예는 특정 서체를 막론하고 한국인의 섬세하고 우아한 격조에서부터 역동적이고 변화무쌍한 생동감은 물론, 즉흥적이고 자유분방한 운치에 이르기까지 한국인의 자연친화적인 정서와 심미의식이 다양한 형태로 반영되어 있다.

      • KCI등재

        Delayed Treatment of Foot Compartment Syndrome: A Case Report and Literature Review

        장지훈,최영,Jang, Jihoon,Choi, Young Korean FootAnkle Society 2021 대한족부족관절학회지 Vol.25 No.1

        Acute compartment syndrome occurs when pressure increases within closed compartments due to injuries causing soft tissue damage. Delayed treatment can lead to undesirable consequences. This paper reports a three-year-old patient in whom a fasciotomy was performed successfully despite the potential side effects. Fasciotomy may be considered when the diagnosis and clinical symptoms of delayed compartment syndrome are clear. This study determined that the three-year-old patient would undergo a relatively smooth recovery compared to elderly patients of advanced age. Because the dorsalis pedis artery pulse was palpable, an emergency surgical treatment was performed to restore the damaged tissues and prevent further necrosis. The patient has shown a satisfactory recovery.

      • 보온재 부착 파이프라인의 부식두께 측정에 관한 연구

        장지훈,조경식,이종오,김기동,Jang, Ji-Hun,Jo, Gyeong-Sik,Lee, Jong-O,Kim, Gi-Dong 한국기계연구원 2001 硏究論文集 Vol.31 No.-

        The wall-thickness of insulated pipelines can be easily evaluated by measuring the gamma-ray transmission intensity because this intensity is inversely proportional to the thickness of insulated pipeline. The main purpose of this study is to develop the nondestructive and filmless on-line inspection system of corrosion by measuring the wall thickness of insulated pipeline. The inspection system is constructed with radioisotope, 64 channel photo diode array detector, crawler system and data taking and operating software. The traditional off-line radiographic method carried out by exposing film cassettes can be replaced by this cost-effective on-line digital imaging method and the application will be greatly expected especially in the chemical and petrochemical industries.

      • 나노 임프린트 공정을 이용한 Ag 나노로드 제조 및 비정질 박막 태양전지 적용

        장지훈(Jang, JiHoon),한강수(Han, Kang-Soo),조준식(Cho, Jun-Sik),이헌(Lee, Heon),박해웅(Park, Hai Woong),송진수(Song, Jinsoo),이정철(Lee, Jeong Chul) 한국신재생에너지학회 2011 한국신재생에너지학회 학술대회논문집 Vol.2011 No.05

        비정질 실리콘 태양전지의 효율을 증가하기 위하여 많이 사용되는 방법 중 하나는 입사되는 빛의 산란을 증가하여 태양전지의 광흡수를 증가시키는 방법이다. 이를 위하여 양극전극으로 사용되는 TCO층의 일정한 패턴 처리를 통하여 광산란을 증가시키는 방법이 사용되고 있다. 본 연구에서는 나노 임프린트 리소그래피방법을 사용하여 Ag 나노로드를 증착한 기판을 제조하고 이를 비정질 실리콘 태양전지에 적용하였다. 실험결과, 그림과 같이 높이와 너비가 300nm 정도로 일정한 패턴의 Ag 나노로드를 제조하였다. 또한, 그 위에 증착된 Si 박막의 경우, 나노로드 전체를 감싸는 돔 형태로 성장하였다. 이와 같은 나노로드 위에 substrate n-i-p 구조의 비정질 박막 태양전지를 증착하고 그 특성변화를 분석하고자 하였다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼