RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        상아질 접착제의 적용이 법랑질 접착에 미치는 영향

        권태엽,권용훈,김교한,송근배 大韓齒科器材學會 2003 대한치과재료학회지 Vol.30 No.2

        The objective of this study was to evaluate the effect of various enamel surface treatments on the bond strength of a composite resin to enamel (n=15). Ground bovine enamel specimens were divided into seven groups. A composite resin (Z250. 3M) was bonded to the specimens using different enamel surface treatments. Four groups examined the effect of application of all-in-one adhesives (Prompt L-Pop (POP), One-Up Bond F (ONE)) with respect to static priming (SP) or dynamic priming (DP). The other two examined use of the POP and ONE after phosphoric acid etching (PE). And the control group provided bond strength of the composite resin to phosphoric acid etched enamel with a resin bonding system (Single bond, SB, 3M). Shear bond strengths for the specimens were measured after 24 hours storage in water at 37 ℃. Effects of various surface treatments on enamel were examined by SEM. Dynamic priming resulted in higher enamel bond strengths than static priming and the best bond strengths were obtained when the enamel was etched with phosphoric acid. SEM analysis showed that depth of etching was related to the bond strengths measured. The enamel etch pattern after static priming showed little retentive surfaces. After dynamic priming, the enamel rod structure has become apparent in the shallow etch. SEM view showed that the resin tags and resin penetration were related to the bond strengths measured. SEM showed minimal resin penetration into enamel following static priming. After application of adhesives to phosphoric acid etched enamel, SEM showed more extended tags that are reflective of the deeper etch pattern.

      • KCI등재후보

        전기화학법에 의해 형성된 Ti 양극산화피막의 특성

        김태영,손원우,권태엽,강인규,김교한 大韓齒科器材學會 2002 대한치과재료학회지 Vol.29 No.3

        The effects of electrolyte concentration and current density on the behaviour of volt-time curve of the anodizing, morphology, roughness, crystallinity and composition of the oxide layer were studied. Microstructural morphology, crystallinity, composition and surface roughness of oxide layer were analyzed by observed by scanning electron microscopy(SEM) and X-ray diffractometry(XRD), Energy-dispersive spectrometer(EDS), Electron Probe Micro Analyzer(EPMA)and roughness tester, respectively. The results of this study showed that the voltage incresed as the anodizing time increase. The growth of the oxide film developed a barrier layer to a pore-like layer with an increasing of current density, arising a spark discharge. On the morphology of anodic oxide layer the number and size of porosity was increased by increasing anodizing time at a constant concentration of electrolyte. The size of porosity and the roughness of the anodic oxide layer were increased by the increasing of concentration of electrolyte. The anodic oxide layer obtained in the conditions of this experiment was identified as anatase. The crystallinity of oxide layer was decreased by increasing the concentration of electrolyte at constant current density, and increased by the increasing current density at constant electrolyte concentration. In the EPMA analysis of anodic oxide layer, the concentration of phosphorous was increasing the electrolyte concentration and increasing the final voltage at constant electrolyte concentration, The ratio of O/Ti of the oxide layer obtained in this experiment was near 2 confirming this oxide layer was TiO₂

      • KCI등재

        Vital Bleaching이 법랑질 접착에 미치는 영향

        김종해,권태엽,권용훈,김교한 大韓齒科器材學會 2003 대한치과재료학회지 Vol.30 No.4

        The objective of this in vitro study was to evaluate the effect of bleaching on the composite to enamel bond and surface hardness change. Extracted human premolars were treated with 35% hydrogen peroxide (Sigma Chemical Co, USA) for 1hr/day at 0, 3, 6 and 9 day respectively. For the obsrvation of surface mophology alteration due to the treatment with hydogen peroxide, a SEM (S-4300, Hitachi, Japan) was used. The specimens were ground flat using serial SiC papers and ground ultra-finely using a 0.1㎛ diamond compound paste. To measure the microhardness, five non-carious premolars were ground using SiC papers and ten indentations were made on the surfacd with Vickers hardness tester (FM-7 FUTURE-TEC Inc., Japan). To evaluate shear bond strength, composite was bonded with One Up Bond-F, Prompt L-Pop, AQ Bond to the non-bleached and bleached enamel surface of sixty non-carious premolars. The bonding procedure is postponed for 1 week after bleaching and shear bond strength was measured. All specimens with a SEM. Bleaching created some enamel porosity but the teeth showed nonsignificant morphological chonge as bleaching time increased from SEM analysis. Most microhardness change occured on the first day of bleaching. Bleaching with 35% hydrogen peroxide did not result in significant change in the shear bond strength of composite resin to enamel. In the shear bond strength test, the fractured surfaces of specimens showed mixed adhesive and cohesive failure behavior.

      • KCI등재

        임플란트 보철물에서 임시 접착용 시멘트의 인장결합강도 비교

        서경숙,권태엽,권용훈,김교한 大韓齒科器材學會 2003 대한치과재료학회지 Vol.30 No.4

        The major disadvantage of cement-retained implant-supported superstructure is difficulty of retrievability. Sometimes, it is recommended that proetheses be provisionally cemented to implant abutment in order to ebaluate occlusion, screw loosening and tissue reaction. The retention of the provisional luting cementedusually employed in this case is considered to be important. This study compared tensile bond strength of gold crowns cemented to machined titanium implant abutments with three provisional luting cements. Also the effect of petrolatum and thermocycling on tensile bond stength were evaluated. Tensile bond strength of provisional luting cement were as follows with the decreasing order of Eugenol (13.06±1.544 kgf), Temp-Bond (9.41±0.737 kgf), Cavex (8.04±0.974 kgf), and Temp-bond with petrolatum (5.28±0.800 kgf). The addition of petrolatum in Temp-bond decreased tensile bond strength significantly (p<0.01). After thermocycling of 1,500 cycles, the tensile bond strengths of the cements were decreased with the order of Nogenol (10.87±3.031 kgf), Temp-Bond (8.1±0.667 kgf), Cavex (7.33±1.103 kgf), Temp-bond with petrolatum (4.88±1.348 kgf). The mocycling decreased the bond strength of Temp-Bond significantly, with no effects no other cements (p<0.01).

      • KCI등재

        금합금의 프라이머 처리가 교정용 브라켓의 접착에 미치는 영향

        류동범,권태엽,권용훈,김교한 大韓齒科器材學會 2003 대한치과재료학회지 Vol.30 No.3

        The purpose of this study was to compare the bonding strength and the interfacial micromorphology of two surface modification of gold alloys in direct bonding of orthodontic brackets. Flat tab of cast gold alloys (n= 120) were subjected to either of two surface treatments: 1.50㎛ aluminum oxide sandblasting, and 2. sandblasting plus adhesive primer for noble metal. Orthodontic brackets (RMO Co.) were bonded directly with Superbond C&B (Sun Medical Co. Ltd.), or Transbond XT (3M Unitek), or Ortho One (Bisco). All specimens were stored in distilled water at 37℃ for 24 hours, and then the tensile bond strength testing was performed in a Instron test machine. Bond failure sites were classified by a modified Adhesive Remnant Index (ARI) system. The results showed that sandblasting plus adhesive primer for noble metal produced stronger bonds to gold alloy than sandblasting only in all cases (Superbond C&B, Transbond XT, Ortho One). Superbond provided significantly stronger bonds to gold alloy than the others. Bond failure of Superbond to sandblast only and sandblast plus adhesive primer for noble metal to gold alloy occurred at the bracket/adhesives interface, whereas bond failure of the others occurred at the gold/adhesive interface. The clinical implications of these findings are discussed.

      • KCI등재

        Influence of storage media on degradation of dental composite resins

        Tae-Yub Kwon(권태엽) 대한치과재료학회 2015 대한치과재료학회지 Vol.42 No.4

        이 연구에서는 세 가지 다른 보관 용액이 두 복합 레진의 화학적 열화에 미치는 영향을 Knoop 경도, 표면 조도, 레진 재료의 무게변화로 평가하였다. Microfilled type의 복합 레진인 Esthet·X와 Clearfil AP-X를 본 실험에 사용하였다. 위 아래 면을 각각 40초 광조사한 레진 시편을 37℃ 증류수에서 24시간 보관한 후 Knoop 경도, 표면 조도, 무게의 초기 값을 측정하였다. 그 후 시편을 pH-cycling, HCl(pH 4.0±0.1), 증류수 중 한 용액(37℃)에 보관하였다(n=5). 3일, 1주, 2주 시편을 보관 후, 위의 값을 측정하여 초기 값과 비교하였고, 2주 보관 후의 시편의 표면 상태를 주사전자현미경으로 관찰하였다. 보관용액에 따른 측정 값의 유의한 차이는 발견되지 않았지만, 산 용액은 pH-cycling과 증류수에 비해 더 많은 열화를 보였다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼