http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Tae-Jun Kwon,Da-Sol Lee,Md. Enamul Haque,Rang-Woon Park,Byungheon Lee,Dongkyu Kim,Yong-Hyun Jeon,Kil-Soo Kim,Sang Kyoon Kim 한국실험동물학회 2021 한국실험동물학회 학술발표대회 논문집 Vol.2021 No.7
The development of reliable methods to diagnose acute kidney injury is essential to allow the adoption of early therapeutic interventions and evaluate their effectiveness. Based on the fact that kidney injury molecule-1 (KIM-1) expression levels in kidneys are markedly upregulated early after a damage event, here we developed a noninvasive KIM- 1-based molecular imaging technique to detect kidney injury. First, we took advantage of a phage-display platform to select small peptides demonstrating a specific high binding affinity to KIM-1. The promising candidate was conjugated with fluorescent probes, and its imaging potential was validated in vitro and in vivo. This peptide, with the sequence CNRRRA, not only showed a high imaging potential in vitro, allowing a strong detection of KIM-1 expressing cells by microscopy and flow cytometry but also generated a strong kidney-specific signal in live-imaging in vivo experiments in the context of a drug-induced kidney-injury mouse model. Our data overall suggest that the CNRRRA peptide is a promising probe to use in the context of in vivo imaging for the detection of KIM-1 overexpression in damaged kidneys.
Kwon,Ki-Tae,Lee,Woo-Sik,Kwon,Lee-Seung,Seong,Seung-Hwan,Kim,Young-Do,Kwon,Woo-Taeg 한국유통과학회 2019 KODISA ICBE (International Conference on Business Vol.2019 No.-
It is possible not only to treat high concentration organic matter such as food wastes but also to utilize food wastes as resources according to the bio-energy generation such as methane. The method of co-digestion of mixed wastewater mixed with organic wastes such as sewage sludge concentrated waters together with drinking wastewater is the most ideal method. Radiation not only has germicidal power in water treatment, but also is effective in decomposing degradable organic matter. Second chemical contamination problem is also solved because it does not use chemicals. Introduction of radiation pretreatment system to solve problems caused by mixing of waste water and organic waste resources. Biological electrochemical fusion system is used to remove the nutrients contained in the organic matter-removed mixture. Through the development of a system for treatment of high concentration wastewater, the processing efficiency is verified through the universal water treatment system for wastewater containing high concentration organic matter in addition to treatment of wastewater.
Design of T-S(Takagi-Sugeno) Fuzzy Control Systems Under the Bound on the Output Energy
Kim, Kwang-Tae,Joh, Joog-Seon,Kwon, Woo-Hyen Institute of Control 1999 Transaction on control, automation and systems eng Vol.1 No.1
This paper presents a new T-S(Tae-Sugeno) fuzzy controller design method satisfying the output energy bound. Maximum output energy via a quadratic Lyapunov function to obtain the bound on output energy is derived. LMI(Linear Matrix Inequality) problems which satisfy an output energy bound for both of the continuous-time and discrete-time T-S fuzzy control system are also derived. Solving these LMIs simultaneously, we find a common symmetric positive definite matrix P which guarantees the global asymptotic stability of the system and stable feedback gains K's satisfying the output energy bound. A simple example demonstrates validity of the proposed design method.
김동훈,김기권,장태정,김정란,이구,김수근,임현술 大韓法醫學會 2001 대한법의학회지 Vol.25 No.1
Oxygen deficiency has been frequent in a clouted space. Wood consumes oxygen and discharges carbon dioxide Instead of photosynthesis in closed space without light, so do some microorganisms on the surface. We experienced a case that a healthy Insect-proofer fell down and died of asphyxia on stair-board at 7 m below the hatch of the cargo-hold shipping wood Analysis of gases in cargo-hold revealed O2; 12.3%, CO; 105 ppm, CH4; 2.7%, and H2S; 1.9% at 1 m below the hatch, and then O2; 6.1%, CO; 220 ppm, CH4; 2.9%, and H2S, 2.3 ppm at 2.5 m below the hatch. Autopsy findings were unremarkable. We justiced the cause of death asphyxia due to oxygen deficiency. As seen in this case, the serious oxygen deficiency was accounted for oxygen consumption by wood and microorganisms.
김영범,박종아,김진해,김권태,김정규,마대영,박기철 경상대학교 생산기술연구소 2001 工學硏究院論文集 Vol.1 No.-
The microsensors to detect NH3 gas were fabricated by continous deposition of In film by evaporation and ZnO film by rf magnetron sputtering onto the Si3N4 diaphragm that was prepared by MEMS technology. The sensors were heat-treated to dope In into the ZnO thin film. The electrical characteristics of sensitive films were studied as a function of heat-temperature by 4-point probing method and electrometer. The dependence of the sensitivity, selectivity and time response of sensor on heat-treatment temperature was investigated. The microsensor heat-treated at 400℃ that 3000 A ZnO:In film was chosen as gas sensitive film, showed the highest sensitivity 23% at 350ppm NH3 under 366mW heater power. The time response was 90sec. The sensitivity for CO and NOx was not observed.
장기간 항갑상선제 투여 후 임의 중단 뒤 재복용시 발생한 무과립구증 1 예
김승만;김태영;박수영;배영환;서영경 정은주;김태균;권민정;박정현;이순희 인제대학교 2011 仁濟醫學 Vol.32 No.-
Agranulocytosis, one of the major side effects of antithyroid a gents, probably occurs in less than 0.25% of cases treated with antithyroid agents. It usually occurs within the first several weeks or months after the initiation of therapy, when drug dosage is higher. Most reported cases of agranulocytosis have occurred during the first 3 months of therapy. We describe here a rare case that did not experience the side effect for 6 years of antithyroid agent treatment but presented with agranulocytosis in one month after re-exposure. It suggests that the major side effect such as agranulocytosis can occur in patients who had undergone prior uneventful antithyroid drug therapy.
김광우,이기호,권오선,고태영 강원대학교 부설 석재복합신소재 제품연구센터 2004 석재연 논문집 Vol.9 No.-
본 연구는 폐비닐 펠렛을 도로포장재료로 재활용하여 자원절약 및 아스팔트 혼합물의 품질향상을 위한 연구이다. 이를 위하여 폐비닐의 첨가량별 배합설계를 수행하여 적정 폐비닐 첨가량과 최적 아스팔트 함량으로 편마암과 화강암 2가지 골재와 폐비닐인 RHDPE의 함량을 4가지로 혼합물을 제작하여 8종류의 재질 혼합물과 2종류의 무개질 혼합물을 제작하였다. 그리고 이 공시체에 대하여 마샬안정도, 간접인장강도 및 Kim test와 반복주행시험 등 실내시험을 통하여 혼합물의 특성을 분석하였다. 폐비닐 첨가량은 RHDPE가 8%일 때 안정도와 간접인장강도 모두 가장 우수한 것으로 나타났고 취성도 나타나지 않았다. RHDPE를 첨가한 혼합물에 대하여 Kim test를 수행한 결과 DR과 DS 모두 높은 상관성을 보였다. 그리고 반복주행시험에서는 RHDPE를 첨가한 혼합물이 일반 혼합물보다 우수하였다. 향후 많은 실험을 통해 RHDPE의 우수성을 입증한다면 소성변형 저항성에 우수한 재료로 이용될 수 있을 것이다. This study is a fundamental research for recycled high-density polyethylene (RHDPE) in asphalt mixture for improving roadway pavement. Marshall mix design was conducted and optimum asphalt content(OAC) was determined for dense-graded surface course mixture by RHDPE content. Marshall stability test, indirect tensile strength (ITS) test, wheel tracking trest and Kim-test were carried out to measure the characteristics of RHDPE-added asphalt concretes. From the results of this study, RHDPE in asphalt mixture if possible. It could be considered that adding too much RHDPE in asphalt mixture is not proper. The optimum content of RHDPE was appeared to be 8%. In Kim-test, statistical analysis was performed for each loading head and aggregate to find out correlation between S_(D) values and each rut parameter. The analysis result showed that S_(D) had very high coefficient of determination with rut parameters on the average.