골수강내 금속정 및 나사못 맞물림을 이용한 경골의 치료
최창혁,권굉우,김신근,이상욱,강창진 대구효성카톨릭대학교 1997 연구논문집 Vol.56 No.2
Fracture of the tibial shaft is the most common among the long bone fractures, and it is difficult to treat because of a high incidence of delayed union, nonunion and malunion. Interlocking Intramedullary mailing is considered to be valuable method in treating long bone fracture such as tibial fracture these days because it enables rigid fixation, early joint motion exercise and weight bearing. Between April 1993 and March 1997, we treated 63 cases of tibia fractures with interlocking intramedullary nailing. The results were as follows: 1. Among the 63 cases, 51 cases were closed fractures and 12 cases were open fractures. 2. Static interlocking nailing was done in all cases and dynamization was done in 7 cases in postoperative 13 weeks. 3. Average union time was 19.9 weeks, 19 weeks with closed tibia fracture and 2.4 weeks with open tibia fracture. According to fracture site, 22 weeks with proximal tibia fracture, 19.2 weeks with mid-tibia fracture and 21.4 weeks with distal tibia fracture. According to the Winquist-Hansen classification, Type I was 19.8 weeks, Type Ⅱ was 20.4 weeks, Type Ⅲ was 22 weeks and Type Ⅳ was 26 weeks. 4. Weight bearing was started at the time of subsidence of pain and tenderness of the fracture site, 11.5 weeks with closed fracture and 12.3 weeks with open fracture. 5. According to the functional result of Klemm and Borner, 44 cases were excellent, 9 cases were good, 7 cases were fair and 3 cases were poor.
표면 플라즈몬 공명 신호의 증폭을 위한 새로운 금 콜로이드 센서칩 제조와 특성 연구
임정혁,이경호,고광락,강신원,김재호 경북대학교 센서기술연구소 1998 센서技術學術大會論文集 Vol.9 No.1
New gold colloidal film sensor chips were employed to enhance the sensitivity of the Surface Plasmon Resonce (SPR). Au collodal solutions were synthesized, and Au colloidal films were fabricated by immobilization of colloid on vacuum deposited Au film through the coupling agent of 1,8-diaminooctane. Specific interaction of human IgG antibody to human antigen was monitored by in situ SPR measurement from both a smooth and a Au colloidal films. Au colloidal film sensor chips resulted in 27 % enhancements effect for the same reaction on SPR angle shifts compared to a smooth Au film.
Kang, Byoung-Ho,Seo, Jun-Seon,Jeong, Sohee,Lee, Jihye,Han, Chang-Soo,Kim, Do-Eok,Kim, Kyu-Jin,Yeom, Se-Hyuk,Kwon, Dae-Hyuk,Kim, Hak-Rin,Kang, Shin-Won The Optical Society 2010 Optics express Vol.18 No.17
<P>We propose a highly efficient hybrid light-emitting device (LED) with a single active layer where CdSe/ZnS quantum dots (QDs) are dispersed as a guest material in a conjugated polymer (co-polymer) matrix used for a host material. In our structure, the QDs act on light-emitting chromophores by trapping the migrating excitons in the co-polymer matrix via F?rster energy transfer, and improve the charge balance within the co-polymer by trapping the injected electron carriers. Experimental results show that the electroluminescent properties highly depend on the doping density of the QDs within the co-polymer matrix, where the luminance as well as the external current efficiency are initially enhanced with increasing the concentration of the dispersed QDs in the co-polymer solution, and then such properties are degraded due to aggregation of the QDs. We can get the maximum brightness of 9,088 cd/m(2) and the maximum external current efficiency of 7.5 cd/A in mixing ratio of the QDs by 1.0 wt%. The external current efficiency is enhanced by over 15 times and the turn-on voltage is reduced in comparison with the corresponding values for a reference device that uses only a co-polymer as an active layer.</P>
Shin Hyuk Kang,Il Young Ahn,Han Koo Kim,Woo Ju Kim,Soo Hyun Woo,Seung Hyun Kang,Soon Auck Hong,Tae Hui Bae Korean Society of Plastic and Reconstructive Surge 2024 Archives of Plastic Surgery Vol.51 No.2
Intraneural hematoma is a rare disease that results in an impaired nerve function because of bleeding around the peripheral nerve, with only 20 cases reported. Trauma, neoplasm, and bleeding disorders are known factors for intraneural hematoma. However, here we report atypical features of asymptomatic and spontaneous intraneural hematoma which are difficult to diagnose. A 60-year-old woman visited our clinic with the complaint of a palpable mass on the right calf. She reported no medical history or trauma to the right calf and laboratory findings showed normal coagulopathy. Ultrasonography was performed, which indicated hematoma near saphenous vein and sural nerve or neurogenic tumor. We performed surgical exploration and intraneural hematoma was confirmed on sural nerve. Meticulous paraneuriotomy and evacuation was performed without nerve injury. Histological examination revealed intraneural hematoma with a vascular wall. No neurologic symptoms were observed. In literature review, we acknowledge that understanding anatomy of nerve, using ultrasonography as a diagnostic tool and surgical decompression is key for intraneural hematoma. Our case report may help establish the implications of diagnosis and treatment. Also, we suggested surgical treatment is necessary even in cases that do not present symptoms because neurological symptoms and associated symptoms may occur later.
Free Flap Reconstruction in Patients with Traumatic Injury of the Forefoot
( Shin Hyuk Kang ),( Jeongseok Oh ),( Seok Chan Eun ) 대한외상학회 2019 大韓外傷學會誌 Vol.32 No.3
Many techniques have been developed for reconstruction of the hand; however, less attention has been paid to foot reconstruction techniques. In particular, reconstruction of the forefoot and big toe has been considered a minor procedure despite the importance of these body parts for standing and walking. Most of the weight load on the foot is concentrated on the forefoot and big toe, whereas the other toes have a minor role in weight bearing. Moreover, the forefoot and big toe are important for maintaining balance and supporting the body when changing directions. Recently, attention has been focused on the aesthetic appearance and functional aspects of the body, which are important considerations in the field of reconstructive surgery. In patients for whom flap reconstruction in the forefoot and big toe is planned, clinicians should pay close attention to f lap survival as well as functional and cosmetic outcomes of surgery. In particular, it is important to assess the ability of the flap to withstand functional weight bearing and maintain sufficient durability under shearing force. Recovery of protective sensation in the forefoot area can reduce the risk of flap loss and promote rapid rehabilitation and functional recovery. Here, we report our experience with two cases of successful reconstruction of the forefoot and big toe with a sensate anterolateral thigh flap, with a review of the relevant literature.