Adaptive Neural PLL for Grid-connected DFIG Synchronization
Ali Bechouche,Djaffar Ould Abdeslam,Tahar Otmane-Cherif,Hamid Seddiki 전력전자학회 2014 JOURNAL OF POWER ELECTRONICS Vol.14 No.3
In this paper, an adaptive neural phase-locked loop (AN-PLL) based on adaptive linear neuron is proposed for grid-connected doubly fed induction generator (DFIG) synchronization. The proposed AN-PLL architecture comprises three stages, namely, the frequency of polluted and distorted grid voltages is tracked online; the grid voltages are filtered, and the voltage vector amplitude is detected; the phase angle is estimated. First, the AN-PLL architecture is implemented and applied to a real three-phase power supply. Thereafter, the performances and robustness of the new AN-PLL under voltage sag and two-phase faults are compared with those of conventional PLL. Finally, an application of the suggested AN-PLL in the grid-connected DFIG-decoupled control strategy is conducted. Experimental results prove the good performances of the new AN-PLL in grid-connected DFIG synchronization.
Adaptive Neural PLL for Grid-connected DFIG Synchronization
Bechouche, Ali,Abdeslam, Djaffar Ould,Otmane-Cherif, Tahar,Seddiki, Hamid The Korean Institute of Power Electronics 2014 JOURNAL OF POWER ELECTRONICS Vol.14 No.3
In this paper, an adaptive neural phase-locked loop (AN-PLL) based on adaptive linear neuron is proposed for grid-connected doubly fed induction generator (DFIG) synchronization. The proposed AN-PLL architecture comprises three stages, namely, the frequency of polluted and distorted grid voltages is tracked online; the grid voltages are filtered, and the voltage vector amplitude is detected; the phase angle is estimated. First, the AN-PLL architecture is implemented and applied to a real three-phase power supply. Thereafter, the performances and robustness of the new AN-PLL under voltage sag and two-phase faults are compared with those of conventional PLL. Finally, an application of the suggested AN-PLL in the grid-connected DFIG-decoupled control strategy is conducted. Experimental results prove the good performances of the new AN-PLL in grid-connected DFIG synchronization.
A C5 Parallel Robot Identification and Control
Brahim Achili,Boubaker Daachi,Arab Ali-cherif,Yacine Amirat 제어·로봇·시스템학회 2010 International Journal of Control, Automation, and Vol.8 No.2
The paper proposes a controller scheme based on a priori identification for a C5 parallel robot. First we realize the identification of dynamic parameters of the robot using the Least Squares technique. Different data are used for this step of identification. The cross validation permitted to select and confirm the identified parameters. After, a control scheme (computed torque) is applied to control the C5 parallel robot. The functions of this control scheme are based on precedent identified parameters. In order to reduce the effect of the identification error, we have added a robustness term based on sliding mode technique. The stability of the system in closed loop is presented using the Lyapunov principle. Experimental results of identification and control are presented and show the effectiveness of our methodology.