RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      Automated Cable Route Design based Flexible Cable Fill Check of Raceway in Cable Spreading of Generating Station

      한글로보기

      https://www.riss.kr/link?id=A101843002

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      In generating station, cable spreading design is a very important task, which is very much time consuming, due to the type of cable used in generating station is very diverse. The raceway means the cable line section from source equipment to destinati...

      In generating station, cable spreading design is a very important task, which is very much time consuming, due to the type of cable used in generating station is very diverse. The raceway means the cable line section from source equipment to destination, and consists of cable tray and conduit. The process of existing cable spreading design was written in by hand. Thereby, there are grossly inefficient gain such as cable omission and unfixed fill value by a personal and time investment. In this paper, we proposed and implemented the automated cable route design based flexible cable fill check in generating station, and proposed the automated cable route design can be calculated the cable fill with flexible changing of raceway. Some experimental result shows that implemented cable route design is well performed and conducted as the design specifications, and it will be able to reduce the cable spreading design time.

      더보기

      국문 초록 (Abstract)

      발전소 설비에서 케이블 포설을 위한 설계는 발전소 설비에 사용되어지는 케이블 유형의 다양한 형태로 인해 매우 많은 시간이 요구되고 매우 중요한 과제이다. 케이블 포설 설계 시 레이스...

      발전소 설비에서 케이블 포설을 위한 설계는 발전소 설비에 사용되어지는 케이블 유형의 다양한 형태로 인해 매우 많은 시간이 요구되고 매우 중요한 과제이다. 케이블 포설 설계 시 레이스웨이(Raceway)는 출발지(Source) 장비로부터 목적지(Destination) 장비까지의 케이블 트레이(Tray) 및 콘디트(Conduit)의 포설 구간을 의미한다. 기존의 케이블 포설 설계 과정은 모두 수기에 의해 작성되어 인적/시간적 투자손실이 크고, 케이블의 누락 및 케이블 오버필(Over Fill)과 같은 비효율적인 손실이 빈번히 발생한다. 따라서 본 논문에서는 효과적인 발전소 케이블 포설 설계를 위한 레이스웨이의 유연한 케이블 오버 필(Fill) 체크 기반의 자동화된 케이블 라우팅 경로 계산 알고리즘을 구현하였고, 제안한 자동화 케이블 라우팅 설계기법은 케이블 위치의 변화에도 유연한 레이스웨이 계산이 가능하다. 구현 결과, 케이블 라우팅 설계 프로그램은 발전소 케이블 포설 설계 사양을 준수하면서 케이블 라우팅 경로를 효과적으로 설정하고, 케이블 포설 설계 시간을 기존 대비 크게 단축하는 성능을 얻을 수 있었다.

      더보기

      참고문헌 (Reference)

      1 Committee Report, "Recommended practice on specific aspects of cable installation in power-generating stations" 4 (4): 1504-1506, 2002

      2 Joseph V. Sheehan, "National Electrical Code 2002 Handbook" NFPA Publication 2001

      3 National Fire Protection Association and Delmar, "NEC 2011Handbook" NFPA Publication 2010

      4 "Insulated Conductors Committee"

      5 "IEEE Std. 690-2004, IEEE Standard for the Design and Installation of Cable Systems for Class 1E Circuits in Nuclear Power Generating Stations"

      6 "IEEE Std. 690-1984, IEEE Standard for the Design and Installation of Cable Systems for Class 1E Circuits in Nuclear Power Generating Stations"

      7 "IEEE Std. 422-2012, IEEE Guide for the Design of Cable Raceway Systems for Electric Generating Facilities"

      8 "IEEE Std. 1185-1994, IEEE Guide for Installation Methods for Generating Station Cables"

      1 Committee Report, "Recommended practice on specific aspects of cable installation in power-generating stations" 4 (4): 1504-1506, 2002

      2 Joseph V. Sheehan, "National Electrical Code 2002 Handbook" NFPA Publication 2001

      3 National Fire Protection Association and Delmar, "NEC 2011Handbook" NFPA Publication 2010

      4 "Insulated Conductors Committee"

      5 "IEEE Std. 690-2004, IEEE Standard for the Design and Installation of Cable Systems for Class 1E Circuits in Nuclear Power Generating Stations"

      6 "IEEE Std. 690-1984, IEEE Standard for the Design and Installation of Cable Systems for Class 1E Circuits in Nuclear Power Generating Stations"

      7 "IEEE Std. 422-2012, IEEE Guide for the Design of Cable Raceway Systems for Electric Generating Facilities"

      8 "IEEE Std. 1185-1994, IEEE Guide for Installation Methods for Generating Station Cables"

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2027 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2018-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2017-12-01 평가 등재후보로 하락 (계속평가) KCI등재후보
      2013-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2011-11-23 학술지명변경 외국어명 : THE JOURNAL OF The KOREAN Institute Of Maritime information & Communication Science -> Journal of the Korea Institute Of Information and Communication Engineering KCI등재
      2011-11-16 학회명변경 영문명 : International Journal of Information and Communication Engineering(IJICE) -> The Korea Institute of Information and Communication Engineering KCI등재
      2011-11-14 학회명변경 한글명 : 한국해양정보통신학회 -> 한국정보통신학회
      영문명 : 미등록 -> International Journal of Information and Communication Engineering(IJICE)
      KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2004-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2002-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.23 0.23 0.27
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.24 0.22 0.424 0.11
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼