RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      Periotest^ⓡ를 이용한 임프란트지지 보철물의 적합도 평가에 관한 연구 = An evaluation of precision fit of implant-supported prosthesis using the periotest^ⓡ

      한글로보기

      https://www.riss.kr/link?id=A19567362

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      In this study, the Periotest value was measured with Periotest?? to evaluate precision fit of the 2-unit and 3-unit implant-supported prosthesis by modifying the size and location of ill-fitted conditions. The 2-unit prosthesis was fabricated with the...

      In this study, the Periotest value was measured with Periotest?? to evaluate precision fit of the 2-unit and 3-unit implant-supported prosthesis by modifying the size and location of ill-fitted conditions. The 2-unit prosthesis was fabricated with the right implant fitted incorrectly and the 3-unit prosthesis with the right and center implant fitted incorrectly.
      To evaluate the effects of the ill-fitted sizes, 4 groups were divided.: The control group being the accurately fabricated sample group fitted properly. Group 1 was constructed with 40㎛ ill-fitted conditions, group 2 with 70㎛ and group 3 with 100㎛ ill-fitted conditions.
      The Periotest value was measured at each implant site after tightening 10Ncm.
      The results was follows:
      1. The PTV on the ill-fitted area in the 2-unit implant-supported prosthesis increased as the ill-fitted conditions increased. There was a statistically significant difference among groups (p<0.05).
      In the same ill-fitted sample, the PTV depending on the measured location demonstrated a statistically significant difference (p<0.05).
      2. The PTV on the ill-fitted area of the 3-unit implant-supported with an ill-fitted condition in the right implant increased as the ill-fitted conditions increased. There was a significant difference among groups (p<0.05).
      In the same ill-fitted sample, the PTV depending on the measured location demonstrated a statistically significant difference (p<0.05).
      3. In the 3-unit implant-supported prosthesis with ill fitting conditions in the center implant, the PTV on the ill-fitted area demonstrated a statistically significant difference between the control group, group 1 and group 2 (p<0.05).
      In the same ill-fitted sample, the PTV depending on the measured location demonstrated significant difference between the gap side and the adjacent side with over 70㎛ ill-fitted conditions (p<0.05).
      The results suggest that Periotest is a valuable objective method for evaluating the precision fit of an implant superstructure.

      더보기

      목차 (Table of Contents)

      • Ⅰ. 서 론
      • Ⅱ. 연구재료 및 방법
      • Ⅲ. 연구 성적
      • Ⅳ. 총괄 및 고찰
      • Ⅴ. 결 론
      • Ⅰ. 서 론
      • Ⅱ. 연구재료 및 방법
      • Ⅲ. 연구 성적
      • Ⅳ. 총괄 및 고찰
      • Ⅴ. 결 론
      • 참고문헌
      • Abstract
      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼