RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS SCIE

      Significant association of coronary stent fracture with in-stent restenosis in sirolimus-eluting stents

      한글로보기

      https://www.riss.kr/link?id=A107648700

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      BACKGROUND: Several reports have suggested that stent fractures in sirolimus-eluting stents (SESs) might be related to in-stent restenosis (ISR). However, the role of stent strut fracture in ISR has not been clearly elucidated. Therefore, we investiga...

      BACKGROUND: Several reports have suggested that stent fractures in sirolimus-eluting stents (SESs) might be related to in-stent restenosis (ISR). However, the role of stent strut fracture in ISR has not been clearly elucidated. Therefore, we investigated the association of the SES fracture and ISR. METHODS: From 2003 to 2006, SES implantations with follow-up coronary angiography (CAG) for 628 lesions in 557 patients were analyzed. We reviewed clinical and procedural factors that might affect SES fracture and ISR. The median time interval from stent implantation to follow-up CAG was 9 months (range: 2–30 months). RESULTS: ISR occurred in 38 patients (5.7%), and 21 stent fractures (3.3%) were identified by follow-up CAG. Fourteen cases occurred in the left anterior descending artery, and seven occurred in the right coronary artery. The binary ISR rate in the stent fracture group was higher compared with that of the nonfracture group (38.1% vs. 4.6%, P<0.001). Predictors of ISR as estimated by multivariate analysis were a stent diameter less than 2.75 mm [odds ratio (OR)=2.76, P=0.012], a stent length over 28 mm (OR=3.30, P=0.024), and stent fracture (OR=11.03, P<0.001) after controlling for the angiographic and clinical risk factors of ISR. CONCLUSION: Stent fracture was an independent predictor of ISR and may be one of the crucial mechanisms of ISR after implantation of an SES.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼